SearcharxivSearch

arXiv subjects

A. Kraft

Publications and source records attributed to A. Kraft.

7 recordsLinked to original sources

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

hep-ex

Design and performance of an absolute $^3$He/Cs magnetometer

We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear spin polarized $^3$He gas by optically pumped cesium magnetometers. We plan to deploy this type of combined magnetometer in an experiment searching for a permanent electric dipole moment of ultracold neutrons at the Paul Scherrer Institute (Switzerland). A prototype magnetometer was built at the University of Fribourg (Switzerland) and tested at Physikalisch-Technische Bundesanstalt (Berlin, Germany). We demonstrate that the combined magnetometer allows Cramér-Rao- limited field determinations with recording times in the range of $\sim 500\mathrm{s}$, measurements above $500\mathrm{s}$ being limited by the stability of the applied magnetic field. % With a $100\mathrm{s}$ recording time we were able to perform an absolute measurement of a magnetic field of $\approx1\mathrm{μT}$ with a standard uncertainty of $ΔB\sim60\mathrm{fT}$, corresponding to $ΔB/B<$6$\times$10$^{-8}$.

physics.atom-ph

The Higgs - photon - Z boson coupling revisited

We analyze the coupling of CP-even and CP-odd Higgs bosons to a photon and a Z boson in extensions of the Standard Model. In particular, we study in detail the effect of charged Higgs bosons in two-Higgs doublet models, and the contribution of SUSY particle loops in the minimal supersymmetric extension of the Standard Model. The Higgs-$γZ$ coupling can be measured in the decay $Z \to γ$+Higgs at $e^+e^-$ colliders running on the Z resonance, or in the reverse process Higgs $\to Z γ$ with the Higgs boson produced at LHC. We show that a measurement of this coupling with a precision at the percent level, which could be the case at future $e^+e^-$ colliders, would allow to distinguish between the lightest SUSY and standard Higgs bosons in large areas of the parameter space.

hep-ph

An Improved Search for the Neutron Electric Dipole Moment

A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.

nucl-ex

Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins

Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.

physics.atom-ph

An optical device for ultra-cold neutrons - Investigation of systematic effects and applications

We developed an optical device for ultra-cold neutrons and investigated the influence of a tilt of its guiding components. A measurement of the time-of-flight of the neutrons through the device by means of a dedicated chopper system was performed and a light-optical method for the alignment of the guiding components is demonstrated. A comparative analysis of former experiments with our results shows the potential of such a device to test the electrical neutrality of the free neutron on the $10^{-22} q_{\rm e}$ level and to investigate the interaction of neutrons with gravity.

physics.ins-det