SearcharxivSearch

arXiv subjects

A. Kulkarni

Publications and source records attributed to A. Kulkarni.

4 recordsLinked to original sources

Focusing of Relativistic Electron Beams With Permanent Magnetic Solenoid

Achieving strong focusing of MeV electron beams is a critical requirement for advanced beam applications such as compact laboratory X-ray sources, high gradient accelerators, and ultrafast electron scattering instrumentation. To address these needs, a compact radially magnetized permanent magnetic solenoid (PMS) has been designed, fabricated, and tested. The solenoid provides a compact and inexpensive solution for delivering high axial magnetic fields (1 Tesla) to focus MeV electron beams. Field characterization of the solenoid demonstrates excellent agreement with analytical models, validating the PMS design. The electron beam test employs a high-brightness photoinjector to study the focusing properties of the PMS. The results indicate a focal length of less than 10 cm and a significant reduction in beam size with small spherical aberrations. Two application cases are evaluated: angular magnification in ultrafast electron diffraction setups and strong focusing for Compton scattering or other microfocus uses.

physics.acc-ph

Assembly, testing, and installation of mPMT photosensor for the Water Cherenkov Test Experiment

The multi-Photomultiplier Tube (mPMT) photosensors will be used in the Water Cherenkov Test Experiment (WCTE) to efficiently detect the photons produced in the whole detector. One of the aims behind the development of WCTE is to test the technology and implement it in future water Cherenkov experiments such as the Hyper-Kamiokande experiment and its Intermediate Water Cherenkov Detector. Each mPMT is built using nineteen 3-inch PMTs arranged on a semi-spherical support matrix. In this paper, we describe the design and manufacture of the mechanical components, the procedures for casting an optical gel between PMTs and acrylic cover, and the overall assembly procedure of the mPMTs. Details of the electronics used in the mPMT modules are not included in this paper and will be presented in a separate publication. We also report on the R&D performed on the selection of the optical gel ratio along with transmittance measurements and the reflectance measurements performed on the aluminium reflector. We also present the optical tests performed on the mPMT module using a 405 nm LED and the resulting increase in the effective photosensitive area by surrounding the PMTs with a reflector. A summary of the production and installation of the mPMTs for the WCTE is also presented in this paper.

physics.ins-det

Square Kilometre Array Science Data Challenge 3a: foreground removal for an EoR experiment

We present and analyse the results of the Science data challenge 3a (SDC3a, https://sdc3.skao.int/challenges/foregrounds), an EoR foreground-removal community-wide exercise organised by the Square Kilometre Array Observatory (SKAO). The challenge ran for 8 months, from March to October 2023. Participants were provided with realistic simulations of SKA-Low data between 106 MHz and 196 MHz, including foreground contamination from extragalactic as well as Galactic emission, instrumental and systematic effects. They were asked to deliver cylindrical power spectra of the EoR signal, cleaned from all corruptions, and the corresponding confidence levels. Here we describe the approaches taken by the 17 teams that completed the challenge, and we assess their performance using different metrics. The challenge results provide a positive outlook on the capabilities of current foreground-mitigation approaches to recover the faint EoR signal from SKA-Low observations. The median error committed in the EoR power spectrum recovery is below the true signal for seven teams, although in some cases there are some significant outliers. The smallest residual overall is $4.2_{-4.2}^{+20} \times 10^{-4}\,\rm{K}^2h^{-3}$cMpc$^{3}$ across all considered scales and frequencies. The estimation of confidence levels provided by the teams is overall less accurate, with the true error being typically under-estimated, sometimes very significantly. The most accurate error bars account for $60 \pm 20$\% of the true errors committed. The challenge results provide a means for all teams to understand and improve their performance. This challenge indicates that the comparison between independent pipelines could be a powerful tool to assess residual biases and improve error estimation.

astro-ph.IM

A Reactive Molecular Dynamics Model for Uranium/Hydrogen Containing Systems

Uranium-based materials are valuable assets in the energy, medical, and military industries. However, understanding their sensitivity to hydrogen embrittlement is particularly challenging due to the toxicity of uranium and computationally expensive nature of the quantum-based methods generally required to study such processes. In this regard, we have developed a Chebyshev Interaction Model for Efficient Simulation (ChIMES) model that can be employed to compute energies and forces of U and UH3 bulk structures with vacancies and hydrogen interstitials with similar accuracy to Density Functional Theory (DFT) while yielding linear scaling and orders of magnitude improvement in computational efficiency. We show that that the bulk structural parameters, uranium and hydrogen vacancy formation energies, and diffusion barriers predicted by the ChIMES potential are in strong agreement with the reference DFT data. We then use ChIMES to conduct molecular dynamics simulations of the temperature-dependent diffusion of a hydrogen interstitial and determine the corresponding diffusion activation energy. Our model has particular significance in studies of actinides and other high-Z materials, where there is a strong need for computationally efficient methods to bridge length and time scales between experiments and quantum theory.

cond-mat.mtrl-sci