SearcharxivSearch

arXiv subjects

A. Lampis

Publications and source records attributed to A. Lampis.

3 recordsLinked to original sources

10 ps timing with highly irradiated 3D trench silicon pixel sensors

In this paper the results of a beam test characterization campaign of 3D trench silicon pixel sensors are presented. A time resolution in the order of 10 ps was measured both for non-irradiated and irradiated sensors up to a fluence of $2.5 \cdot 10^{16}\,1\,MeV\, n_{eq}\,cm^{-2}$. This feature and a detection efficiency close to $99\%$ make this sensors one of the best candidates for 4D tracking detectors in High-Energy-Physics experiments.

physics.ins-det

200 mm Sensor Development Using Bonded Wafers

Sensors fabricated from high resistivity, float zone, silicon material have been the basis of vertex detectors and trackers for the last 30 years. The areas of these devices have increased from a few square cm to $\> 200\ m^2$ for the existing CMS tracker. High Luminosity Large Hadron Collider (HL-LHC), CMS and ATLAS tracker upgrades will each require more than $200\ m^2$ of silicon and the CMS High Granularity Calorimeter (HGCAL) will require more than $600\ m^2$. The cost and complexity of assembly of these devices is related to the area of each module, which in turn is set by the size of the silicon sensors. In addition to large area, the devices must be radiation hard, which requires the use of sensors thinned to 200 microns or less. The combination of wafer thinning and large wafer diameter is a significant technical challenge, and is the subject of this work. We describe work on development of thin sensors on $200 mm$ wafers using wafer bonding technology. Results of development runs with float zone, Silicon-on-Insulator and Silicon-Silicon bonded wafer technologies are reported.

physics.ins-det

Why material slow light does not improve cavity-enhanced atom detection

We discuss the prospects for enhancing absorption and scattering of light from a weakly coupled atom in a high-finesse optical cavity by adding a medium with large, positive group index of refraction. The slow-light effect is known to narrow the cavity transmission spectrum and increase the photon lifetime, but the quality factor of the cavity may not be increased in a metrologically useful sense. Specifically, detection of the weakly coupled atom through either cavity ringdown measurements or the Purcell effect fails to improve with the addition of material slow light. A single-atom model of the dispersive medium helps elucidate why this is the case.

physics.atom-ph