R&D on a high-performance electromagnetic calorimeter based on oriented crystalline scintillators

Although inorganic scintillators are widely used in the design of electromagnetic calorimeters for high-energy physics and astrophysics, their crystalline nature and, hence, their lattice orientation are generally neglected in the detector design. However, in general, the features of the electromagnetic field experienced by the particles impinging on a crystal at a small angle with respect to a lattice axis affect their interaction mechanisms. In particular, in case of electrons/photons of $\mathcal{O} (10~\mathrm{GeV})$ or higher impinging on a high-$Z$ crystal at an angle of $\lesssim 1~\mathrm{mrad}$, the so-called strong field regime is attained: the bremsstrahlung and pair production cross sections are enhanced with respect to the case of amorphous or randomly oriented materials. Overall, the increase of these processes leads to an acceleration of the electromagnetic shower development. These effects are thoroughly investigated by the OREO (ORiEnted calOrimeter) team, and pave the way to the development of innovative calorimeters with a higher energy resolution, a higher efficiency in photon detection and an improved particle identification capabilities due to the relative boost of the electromagnetic interactions with respect to the hadronic ones. Moreover, a detector with the same resolution as the current state of the art and reduced thickness could be developed. An overview of the lattice effects at the foundation of the shower boost and of the current status of the development of an operational calorimeter prototype are presented. This concept could prove pivotal for both accelerator fixed-target experiments and satellite-borne $\gamma$-ray observatories.

physics.ins-det

Steps in creation of educational and research web-portal of nuclear knowledge BelNET

Belarusian State University is currently developing the educational and research web portal of nuclear knowledge BelNET (Belarusian Nuclear Education and Training Portal). In the future, this specialized electronic portal could grow into a national portal of nuclear knowledge. The concept, structure and taxonomy of BelNET portal are developed. The requirements and conditions for its functioning are analyzed. The information model and architecture of the portal, as well as algorithms and methods of software are realized. At present, BelNET software implemented all the basic functions of this portal, including the ability to remotely (via the Internet) open content editing, sorting, filtering, etc. Filling the BelNET by knowledge is at the beginning.

cs.CY

Generation of Medical X-ray and Terahertz Beams of Radiation Using Table-Top Accelerators

Theoretical and experimental studies of PXR and diffracted radiation of an oscillator in crystals combined with the development of VFEL generators with photonic crystals give a promising basis for creation of X-ray and THz sources using the same table-top accelerator. Multi-modal medical facility can be developed on the basis of one dedicated table-top electron accelerator of some tens of MeV energy. Such a system could find a lot of applications in medical practice and biomedical investigations.

physics.acc-ph

Application of PbWO4 crystal scintillators in experiment to search for double beta decay of 116Cd

PbWO4 crystal scintillators are discussed as an active shield and light-guides in 116Cd double beta decay experiment with CdWO4 scintillators. Scintillation properties and radioactive contamination of PbWO4 scintillators were investigated. Energy resolution of CdWO4 detector, coupled to PbWO4 crystal as a light-guide, was tested. Efficiency of PbWO4-based active shield to suppress background from the internal contamination of PbWO4 crystals was calculated. Using of lead tungstate crystal scintillators as high efficiency 4-pi active shield could allow to build sensitive double beta experiment with 116CdWO4 crystal scintillators.

nucl-ex

On the Radiation Damage of BTeV EMCAL Detector Unit

Hamamatsu photomultiplier tubes (PMT) and various PMT window materials were exposed to gamma irradiation. Tests were performed with absorbed doses of 1 krad and 120 krad. Initial recommendations on PMT types to use in the BTeV electromagnetic calorimeter are stated.

physics.ins-det

Position-Sensitive Detector with Depth-of-Interaction Determination for Small Animal PET

Crystal arrays made of LSO and LuAP crystals 2x2x10 mm pixels were manufactured for evaluation of detector with depth-of-interaction (DOI) determination capability intended for small animal positron emission tomograph. Position-sensitive LSO/LuAP phoswich DOI detector based on crystal 8x8 arrays and HAMAMATSU R5900-00-M64 position-sensitive multi-anode photomultiplier tube was developed and evaluated. Time resolution was found to be not worse than 1.0 ns FWHM for both layers, and spatial resolution mean value was 1.5 mm FWHM for the center of field-of-view.

physics.ins-det

Progress of the Volume FEL (VFEL) experiments in millimeter range

Use of non one-dimensional distributed feedback in VFEL gives possibility of frequency tuning in wide range. In present work dependence of lasing process on the angle between resonant diffraction grating grooves and direction of electron beam velocity is discussed.

physics.optics

First Lasing of Volume FEL (VFEL) at Wavelength Range $λ\sim $ 4-6 mm

First lasing of volume free electron laser (VFEL) is described. The generating system consists of two metal diffraction grating with different spatial periods. The first grating creates the conditions for Smith Purcell emission mechanism. The second grating provides the distributed feedback for emitted wave. The length of diffraction grating is 10 cm. Electron beam pulse with a time duration $τ\sim$ 10 ms has a sinusoidal form with the amplitude varied from 1 to ~10 kV. The measured microwave power reached the value of about 3-4 W in mm wavelength range. The generation stops at threshold current value. When the current tends to the threshold value, the region of generation tends to a narrow band near to 5 kV. At higher current values the radiation appears in electron energy range 5 - 7.5 KeV.