SearcharxivSearch

arXiv subjects

A. Luiten

Publications and source records attributed to A. Luiten.

3 recordsLinked to original sources

Fast machine-learning online optimization of ultra-cold-atom experiments

Machine-designed control of complex devices or experiments can discover strategies superior to those developed via simplified models. We describe an online optimization algorithm based on Gaussian processes and apply it to optimization of the production of Bose-Einstein condensates (BEC). BEC is typically created with an exponential evaporation ramp that is approximately optimal for s-wave, ergodic dynamics with two-body interactions and no other loss rates, but likely sub-optimal for many real experiments. Machine learning using a Gaussian process, in contrast, develops a statistical model of the relationship between the parameters it controls and the quality of the BEC produced. This is an online process, and an active one, as the Gaussian process model updates on the basis of each subsequent experiment and proposes a new set of parameters as a result. We demonstrate that the Gaussian process machine learner is able to discover a ramp that produces high quality BECs in 10 times fewer iterations than a previously used online optimization technique. Furthermore, we show the internal model developed can be used to determine which parameters are essential in BEC creation and which are unimportant, providing insight into the optimization process.

quant-ph

First observation of feshbach resonances at very low magnetic field in a 133Cs fountain

One of the main limitations of cesium atomic fountains has been the cold collision frequency shift. By using a method based on a transfer of population by adiabatic passage allowing to prepare cold atomic samples with a well defined ratio of atomic density as well as atom number the collisional shift is controlled at the 10E-3 of its value. A calibration of Zeeman sub-states contribution to the clock shift as a function of the field has been performed. Feshbach resonances have been observed for the first time at very low magnetic field and with a very good resolution. A Monte Carlo simulation has been performed and could fit properly some of experimental data. This constrains some parameters of the theory of collisions.

physics.atom-ph

Cold atom Clocks and Applications

This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of $1.6\times 10^{-14}τ^{-1/2}$ where $τ$ is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of $2\times 10^{-16}$ at $50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of $7\times 10^{-16}$, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using $^{87}$Rb and $^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.

physics.atom-ph