Searcharxiv⌕ Search

arXiv subjects

A. M. Artikov

Publications and source records attributed to A. M. Artikov.

4 recordsLinked to original sources

The Super Fine-Grained Detector for the T2K neutrino oscillation experiment

The magnetised near detector ND280 of the long-baseline neutrino experiment T2K has been upgraded to improve its detection performance and, consequently, enhance our understanding of neutrino-nucleus interactions, reducing the systematic uncertainties in measurements of the neutrino oscillation parameters. A key component of the upgrade is a novel segmented plastic scintillator detector, called the Super Fine-Grained Detector (SuperFGD), made of approximately 2 million optically isolated 1 cm$^3$ cubes read out by three orthogonal wavelength-shifting (WLS) fibres. Scintillation photons are detected by 55,888 Hamamatsu Multi-Pixel Photon Counters (MPPCs). The SuperFGD provides 3D images of neutrino interactions by tracking the final-state charged particles produced isotropically, including protons down to a threshold of around 330 MeV/$c$. The high light yield of SuperFGD greatly improves particle identification and the sub-nanosecond time resolution provides an excellent identification of Michel electrons. The SuperFGD is also able to detect neutrons from neutrino interactions and, for the first time in a neutrino experiment, to reconstruct their kinetic energy using a fine detector segmentation and by measuring the time-of-flight with sub-nanosecond precision. In this article the details of the detector design, construction and performance are described. The detector was installed in ND280 and successfully commissioned with cosmic data in 2023 and, later, with the T2K neutrino beam. The detector response has been characterised with the 2023 and 2024 data and the results are reported in this article.

physics.ins-det↗

Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

physics.ins-det↗

Suppression of the slow component of BaF$_{2}$ crystal luminescence with a thin multilayer filter

The fast component of the barium fluoride (BaF$_{2}$) crystal luminescence with the emission peak at 220 nm allows those crystals to be employed in fast calorimeters operating in harsh radiation environment. However, the slow component with the emission peak at 330 nm and about 85\% of the total emission light could create big problems when working at a high radiation rate. In this work we report results of tests of multilayer filters that can suppress luminescence in the range from 250 nm to 400 nm, which covers most of the BaF$_{2}$ slow component luminescence. The filters are made by spraying layers of rare earth oxides on a quartz glass substrate. Filters typically comprise 200-220 layers. A few filters were prepared by spraying thin layers on quartz glass. The filters have a peak transmittance of about 70-80\% in the range of 200-250 nm. Measurements of the light output of the BaF$_{2}$ crystal with and without a filter between the crystal readout end and the PMT demonstrate substancial suppression of the slow component. To our knowledge, this kind of filters are produced and tested for the first time.

physics.ins-det↗

Mu2e Technical Design Report

The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.

physics.ins-det↗