Gamma Imagers for Nuclear Security and Nuclear Forensics: Recommendations based on results from a side-by-side intercomparison

Nuclear security operations and forensic investigations require the utilization of a suite of instruments ranging from passive gamma spectrometers to high-precision laboratory sample analyzers. Gamma spectroscopy survey is further broken down into wide-area search performed with large-volume scintillator-based mobile survey spectrometers which are integrated with geographic position sensors for mapping and identification of hot zones, and high-precision long-dwell measurements using solid state spectrometers for follow-on characterization to establish isotopic content and ratios. While performing well at detecting the presence, quantity and type of radioactivity, all of these methods have limited ability to determine the location of a source of radioactivity. In recent years, technology advances have resulted in gamma imager devices which can create an image of the distribution of radioactive sources using the gamma emissions which accompany radioactive decay, and overlay this on an optical photograph of the environment. These gamma imaging devices have arisen out of methods developed for medical physics, experimental particle physics, and astrophysics, resulting in a proliferation of different technological approaches. Those responsible for establishing a nuclear security concept of operations, require guidance to choose the proper gamma imager for each of the application spaces in a tiered response. Here the results of an intercomparison of two gamma imagers based on two widely different technologies, semiconductor and scintillator detectors, are presented. The optimal utilization of these imaging technologies in a tiered response is discussed based on the results of the trial. Finally, an outlook on future directions for gamma imaging advances is provided.

physics.ins-det↗

A Directional Gamma-Ray Detector Based on Scintillator Plates

A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising a plate of CsI(Tl) scintillator coupled to a photomultiplier tube, can locate a point source of gamma rays with degree-scale precision by comparing the count rates in the different modules. Sensitivity to uniform environmental background is minimal.

physics.ins-det↗

Development of a Compton imager based on bars of scintillator

We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and absorber) employ bars of NaI(Tl) read out by photomultiplier tubes (PMTs) located at each end. The long-range imaging performance has been tested from 392 keV to 1274 keV. An angular resolution measure of 2.72 +/- 0.06 degrees and an efficiency of (1.79 +/- 0.04) x 10^(-3) at 662 keV is obtained. A Cs-137 (662 keV) source equivalent to a 10 mCi source 40 m away can be located in 60 seconds with an uncertainty of about a degree. No significant degradation in imaging performance is observed for source angles up to 40 degrees off axis.

physics.ins-det↗

First demonstration of a Compton gamma imager based on silicon photomultipliers

We are developing a rugged and person-transportable Compton gamma imager for use in security investigations of radioactive materials, and for radiological incident remediation. The imager is composed of layers of scintillator with light collection for the forward layers provided by silicon photomultipliers and for the rear layer by photomultiplier tubes. As a first step, we have developed a 1/5th-scale demonstration unit of the final imager. We present the imaging performance of this demonstration unit for Cs-137 at angles of up to 30 degrees off-axis. Results are also presented for Sn-113 and Na-22. This represents the first demonstration of the use of silicon photomultipliers as an embedded component for light collection in a Compton gamma imager.

physics.ins-det↗

Simulations of a Scintillator Compton Gamma Imager for Safety and Security

We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid scintillator for the active volumes of both the scatter and absorber detectors. Using the BEAMnrc/EGSnrc Monte Carlo simulation package, we have constructed models using four different materials for the scatter detector: LaBr_3, NaI, CaF_2 and PVT. We have compared the detector performances using angular resolution, efficiency, and image resolution. We find that while PVT provides worse performance than that of the detectors based entirely on inorganic scintillators, all of the materials investigated for the scatter detector have the potential to provide performance adequate for our purposes.