SearcharxivSearch

arXiv subjects

A. Maki

Publications and source records attributed to A. Maki.

6 recordsLinked to original sources

Neutron-induced reaction cross section measurements on carbon at neutron energies up to 55 MeV at LANSCE

Background: Single-crystal chemical vapor deposited (sCVD) diamond detectors offer a unique method to study cross sections of reactions on carbon since they can be used as active targets. Previous studies analyzing neutrons on carbon using these detectors were primarily focused on lower energy neutrons and reactions, and some of these did not have sufficient energy resolution to isolate the contributions of reaction channels with similar Q values. Purpose: This work extends neutron-induced reaction cross section measurements to higher energies, relevant to rare isotope facilities. These measurements can be used to inform and benchmark simulation of experiments that require neutron detection, particularly those utilizing organic scintillators. For some experiments, simulations are used to extract physics information from experimental data, reinforcing the need for accurate simulations. Methods: Two sCVD diamond detectors were used as active targets at LANSCE, where neutrons up to 800 MeV are produced via spallation. Results: Relative cross sections are reported from incident neutron (kinetic) energies E$_n$ = 12 MeV up to 55 MeV for $^{12}$C(n,$\alpha_0$), up to 46 MeV for $^{12}$C(n,d$_0$), and up to 27 MeV for $^{12}$C(n,p$_0$) and $^{12}$C(n,p$_1$). These measurements extend these cross sections to higher energies than those of previous studies. Conclusions: Good agreement is found between this work and recent experimental data from the EXFOR database in the neutron energies where the studies overlap. This work supports the need to update the ENDF evaluation for the (n,$\alpha_0$) channel with more recent data, and provides data that could allow for an evaluation of the (n,p$_0$), (n,p$_1$), and (n,d$_0$) channels. These cross sections will increase the accuracy of simulations by extending the energy range for which empirical cross sections are available.

nucl-ex

New constraint on the existence of the mu+-> e+ gamma decay

The analysis of a combined data set, totaling 3.6 \times 10^14 stopped muons on target, in the search for the lepton flavour violating decay mu^+ -> e^+ gamma is presented. The data collected by the MEG experiment at the Paul Scherrer Institut show no excess of events compared to background expectations and yield a new upper limit on the branching ratio of this decay of 5.7 \times 10^-13 (90% confidence level). This represents a four times more stringent limit than the previous world best limit set by MEG.

hep-ex

The MEG detector for $μ+\to e+γ$ decay search

The MEG (Mu to Electron Gamma) experiment has been running at the Paul Scherrer Institut (PSI), Switzerland since 2008 to search for the decay \meg\ by using one of the most intense continuous $μ^+$ beams in the world. This paper presents the MEG components: the positron spectrometer, including a thin target, a superconducting magnet, a set of drift chambers for measuring the muon decay vertex and the positron momentum, a timing counter for measuring the positron time, and a liquid xenon detector for measuring the photon energy, position and time. The trigger system, the read-out electronics and the data acquisition system are also presented in detail. The paper is completed with a description of the equipment and techniques developed for the calibration in time and energy and the simulation of the whole apparatus.

physics.ins-det

New limit on the lepton-flavour violating decay mu -> e gamma

We present a new result based on an analysis of the data collected by the MEG detector at the Paul Scherrer Institut in 2009 and 2010, in search of the lepton flavour violating decay mu->e gamma. The likelihood analysis of the combined data sample, which corresponds to a total of 1.8 x 10**14 muon decays, gives a 90% C.L. upper limit of 2.4 x 10**-12 on the branching ratio of the mu->e gamma decay, constituting the most stringent limit on the existence of this decay to date.

hep-ex

A limit for the mu -> e gamma decay from the MEG experiment

A search for the decay mu -> e gamma, performed at PSI and based on data from the initial three months of operation of the MEG experiment, yields an upper limit on the branching ratio of BR(mu -> e gamma) < 2.8 x 10**-11 (90% C.L.). This corresponds to the measurement of positrons and photons from ~ 10**14 stopped mu-decays by means of a superconducting positron spectrometer and a 900 litre liquid xenon photon detector.

hep-ex

Absorption of Scintillation Light in a 100 $\ell$ Liquid Xenon$γ$ Ray Detector and Expected Detector Performance

An 800L liquid xenon scintillation $γ$ ray detector is being developed for the MEG experiment which will search for $μ^+\to\mathrm{e}^+γ$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by impurities might possibly limit the performance of such a detector. We used a 100L prototype with an active volume of 372x372x496 mm$^3$ to study the scintillation light absorption. We have developed a method to evaluate the light absorption, separately from elastic scattering of light, by measuring cosmic rays and $α$ sources. By using a suitable purification technique, an absorption length longer than 100 cm has been achieved. The effects of the light absorption on the energy resolution are estimated by Monte Carlo simulation.

physics.ins-det