SearcharxivSearch

arXiv subjects

A. Mangu

Publications and source records attributed to A. Mangu.

5 recordsLinked to original sources

The SPT-3G+ receiver design

We present the thermo-mechanical design of the cryostat and camera optics for SPT-3G+, a new receiver being developed for the South Pole Telescope (SPT). The receiver consists of 14 detector arrays of 90/150 GHz dichroic polarization-sensitive pixels, totaling 24,080 transition-edge sensor detectors. Each detector array lies at the end of an optics tube, each approximately 240 mm in diameter and 772 mm in length, which are arranged in a hexagonal close-packed configuration to achieve a 4 degree diameter field of view. Each optics tube contains four anti-reflection coated lenses fabricated from different materials (alumina, silicon, and nylon) that are designed to also provide infrared filtering that reduces the radiative loading on the cryogenic stages. The optics and detectors are cooled by a combination of a pulse tube cooler for the 40 K and 4 K stages, and a dilution refrigerator for the 1 K and 100 mK stages. Thermal modeling predicts the heat load to be less than 26 W and 1 W for the 40 K and 4 K stages, respectively. The 1,550 kg cryostat has a 1.1 meter diameter at the vacuum window, which is located near the telescope Gregorian focus, and 1.75 meters in height and length. Fabrication of the cryostat will begin in 2026, with installation on the SPT scheduled for the 2028-29 austral summer, ahead of the 2029 winter observing season.

astro-ph.IM

SPT-3G+: A Cosmic Microwave Background Experiment for the South Pole Telescope

SPT-3G+ is the next survey receiver planned to be installed in early 2029 on the 10-meter South Pole Telescope (SPT). This new receiver will feature 6,020 polarization-sensitive dichroic pixels with transition-edge sensors observing in frequency bands centered at 90 GHz and 150 GHz. The 24,080 detectors in the SPT-3G+ receiver will be cooled to 100 mK by a dilution refrigerator and read out using microwave SQUID multiplexing. The optical design of the receiver enables a 4 degree diameter field of view, which is broken up into 14 individual optics tubes each containing cryogenic alumina, silicon, and nylon lenses. These technology choices will allow the SPT-3G+ receiver to improve on the mapping speed of the currently operating SPT-3G receiver by nearly an order of magnitude. Once deployed, the SPT-3G+ receiver will observe for 6-years an area overlapping with the BICEP survey to achieve a combined (90 GHz and 150 GHz) CMB map depth of 0.5 uK-arcmin. Data from these observations will be used to create unprecedentedly deep CMB lensing maps, discover new galaxy clusters, and detect astrophysical transients. The lensing map produced by SPT-3G+ will be used to remove or "delens" foreground B modes, where large-scale structure gravitationally lenses the CMB and converts E modes into B-mode polarization, with the goal of revealing inflationary B modes. Together with data from the BICEP Array as part of the South Pole Observatory, SPT-3G+ data will be used to constrain the tensor-to-scalar ratio $r$ with a goal of achieving a measurement of $\sigma(r) = 0.001$

astro-ph.CO

Hidden domain boundary dynamics towards crystalline perfection

A central paradigm of non-equilibrium physics concerns the dynamics of heterogeneity and disorder, impacting processes ranging from the behavior of glasses to the emergent functionality of active matter. Understanding these complex mesoscopic systems requires probing the microscopic trajectories associated with irreversible processes, the role of fluctuations and entropy growth, and the timescales on which non-equilibrium responses are ultimately maintained. Approaches that illuminate these processes in model systems may enable a more general understanding of other heterogeneous non-equilibrium phenomena, and potentially define ultimate speed and energy cost limits for information processing technologies. Here, we apply ultrafast single shot x-ray photon correlation spectroscopy to resolve the non-equilibrium, heterogeneous, and irreversible mesoscale dynamics during a light-induced phase transition. This approach defines a new way of capturing the nucleation of the induced phase, the formation of transient mesoscale defects at the boundaries of the nuclei, and the eventual annihilation of these defects, even in systems with complex polarization topologies. A non-equilibrium response spanning >10 orders of magnitude in timescales is observed, with multistep behavior similar to the plateaus observed in supercooled liquids and glasses. We show how the observed time-dependent long-time correlations can be understood in terms of the stochastic dynamics of domain walls, encoded in effective waiting-time distributions with power-law tails. This work defines new possibilities for probing the non-equilibrium and correlated dynamics of disordered and heterogeneous media.

cond-mat.mtrl-sci

The Simons Observatory: Cryogenic Half Wave Plate Rotation Mechanism for the Small Aperture Telescopes

We present the requirements, design and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background (CMB) polarization experiment at Parque Astron\'{o}mico Atacama in northern Chile that covers a wide range of angular scales using both small (0.42 m) and large (6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric $1/f$ noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to $\sim$50 K to reduce detector thermal loading. Under normal operation the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism's vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 $\mu$rad$\sqrt{\mathrm{s}}$. During a cooldown, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

astro-ph.IM

A Measurement of the Degree Scale CMB B-mode Angular Power Spectrum with POLARBEAR

We present a measurement of the $B$-mode polarization power spectrum of the cosmic microwave background (CMB) using taken from July 2014 to December 2016 with the POLARBEAR experiment. The CMB power spectra are measured using observations at 150 GHz with an instantaneous array sensitivity of $\mathrm{NET}_\mathrm{array}=23\, μ\mathrm{K} \sqrt{\mathrm{s}}$ on a 670 square degree patch of sky centered at (RA, Dec)=($+0^\mathrm{h}12^\mathrm{m}0^\mathrm{s},-59^\circ18^\prime$). A continuously rotating half-wave plate is used to modulate polarization and to suppress low-frequency noise. We achieve $32\,μ\mathrm{K}$-$\mathrm{arcmin}$ effective polarization map noise with a knee in sensitivity of $\ell = 90$, where the inflationary gravitational wave signal is expected to peak. The measured $B$-mode power spectrum is consistent with a $Λ$CDM lensing and single dust component foreground model over a range of multipoles $50 \leq \ell \leq 600$. The data disfavor zero $C_\ell^{BB}$ at $2.2σ$ using this $\ell$ range of POLARBEAR data alone. We cross-correlate our data with Planck high frequency maps and find the low-$\ell$ $B$-mode power in the combined dataset to be consistent with thermal dust emission. We place an upper limit on the tensor-to-scalar ratio $r < 0.90$ at 95% confidence level after marginalizing over foregrounds.

astro-ph.CO