SearcharxivSearch

arXiv subjects

A. Martemiyanov

Publications and source records attributed to A. Martemiyanov.

8 recordsLinked to original sources

Assessment of the potential of SiPM-based systems for bioluminescence detection

Bioluminescence detection requires single-photon sensitivity, extremely low detection limits and wide dynamic range. Such performances were traditionally assured by photomultiplier-tubes based systems. However, development of novel applications and industrialisation call for the introduction of more robust, compact and scalable devices. Silicon photomultipliers were recently put forward as the alternative to phototubes for a new generation of flexible and user friendly instruments. In this article, the figures of merit of a silicon-photomultiplier based system relying on a compact, low cost system are investigated. Possible implementations are proposed and a proof-of-principle bioluminescence measurement is performed.

physics.ins-det

An Educational Kit Based on a Modular Silicon Photomultiplier System

Silicon Photo-Multipliers (SiPM) are state of the art light detectors with unprecedented single photon sensitivity and photon number resolving capability, representing a breakthrough in several fundamental and applied Science domains. An educational experiment based on a SiPM set-up is proposed in this article, guiding the student towards a comprehensive knowledge of this sensor technology while experiencing the quantum nature of light and exploring the statistical properties of the light pulses emitted by a LED.

physics.ins-det

Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 hours, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.

physics.ins-det

Multiplicity Studies and Effective Energy in ALICE at the LHC

In this work we explore the possibility to perform ``effective energy'' studies in very high energy collisions at the CERN Large Hadron Collider (LHC). In particular, we focus on the possibility to measure in $pp$ collisions the average charged multiplicity as a function of the effective energy with the ALICE experiment, using its capability to measure the energy of the leading baryons with the Zero Degree Calorimeters. Analyses of this kind have been done at lower centre--of--mass energies and have shown that, once the appropriate kinematic variables are chosen, particle production is characterized by universal properties: no matter the nature of the interacting particles, the final states have identical features. Assuming that this universality picture can be extended to {\it ion--ion} collisions, as suggested by recent results from RHIC experiments, a novel approach based on the scaling hypothesis for limiting fragmentation has been used to derive the expected charged event multiplicity in $AA$ interactions at LHC. This leads to scenarios where the multiplicity is significantly lower compared to most of the predictions from the models currently used to describe high energy $AA$ collisions. A mean charged multiplicity of about 1000-2000 per rapidity unit (at $η\sim 0$) is expected for the most central $Pb-Pb$ collisions at $\sqrt{s_{NN}} = 5.5 TeV$.

hep-ph

START as the detector of choice for large-scale muon triggering systems

Further progress in building high-granular large-scale systems based on Scintillation Tiles with MRS APD light readout (START) became possible thanks to the creation of an improved version of MRS APD. The cost of the system may now be significantly reduced by using inexpensive extruded scintillator. More than 160 START samples were assembled based on this design modification and proved to possess 100% MIP detection efficiency and the intrinsic noise rate of less than 0.08 Hz. Long-term stability of START characteristics was confirmed after 3.5 months of operation.

physics.ins-det

Scintillation counter with MRS APD light readout

START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.

physics.ins-det

100 ps time-of-flight resolution of Dielectric Resistive Plate Chamber

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with different applied voltages, discriminating thresholds and beam intensities. It may be stated that the time-of-flight resolution of gaseous detectors developed within the ALICE experiment has reached the level of the best known scintillation counters.

physics.ins-det

Dielectric Resistive Plate Chamber as a detector for time-of-flight measurements

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of applied voltages. Double-gap DRPCs have demonstrated the MIP registration efficiency of 97% and the time resolution of 180-200 ps. No changes in DRPC operation have been observed with test beam intensities up to 10^3 Hz/cm^2.

physics.ins-det