Searcharxiv⌕ Search

arXiv subjects

A. Martini

Publications and source records attributed to A. Martini.

27 records · Page 2Linked to original sources

Embedded Readout Electronics R&D for the Large PMTs in the JUNO Experiment

Jiangmen Underground neutrino Observatory (JUNO) is a next generation liquid scintillator neutrino experiment under construction phase in South China. Thanks to the anti-neutrinos produced by the nearby nuclear power plants, JUNO will primarily study the neutrino mass hierarchy, one of the open key questions in neutrino physics. One key ingredient for the success of the measurement is to use high speed, high resolution sampling electronics located very close to the detector signal. Linearity in the response of the electronics in another important ingredient for the success of the experiment. During the initial design phase of the electronics, a custom design, with the Front-End and Read-Out electronics located very close to the detector analog signal has been developed and successfully tested. The present paper describes the electronics structure and the first tests performed on the prototypes. The electronics prototypes have been tested and they show good linearity response, with a maximum deviation of 1.3% over the full dynamic range (1-1000 p.e.), fulfilling the JUNO experiment requirements.

physics.ins-det↗

$^{222}$Rn contamination mechanisms on acrylic surfaces

In this work, the $^{222}$Rn contamination mechanisms on acrylic surfaces have been investigated. $^{222}$Rn can represent a significant background source for low-background experiments, and acrylic is a suitable material for detector design thanks to its purity and transparency. Four acrylic samples have been exposed to a $^{222}$Rn rich environment for different time periods, being contaminated by $^{222}$Rn and its progenies. Subsequently, the time evolution of radiocontaminants activity on the samples has been evaluated with $α$ and $γ$ measurements, highlighting the role of different decay modes in the contamination process. A detailed analysis of the alpha spectra allowed to quantify the implantation depth of the contaminants. Moreover, a study of both $α$ and $γ$ measurements pointed out the $^{222}$Rn diffusion inside the samples.

physics.ins-det↗

Distillation and stripping pilot plants for the JUNO neutrino detector: design, operations and reliability

This paper describes the design, construction principles and operations of the distillation and stripping pilot plants tested at the Daya Bay Neutrino Laboratory, with the perspective to adapt this processes, system cleanliness and leak-tightness to the final full scale plants that will be used for the purification of the liquid scintillator used in the JUNO neutrino detector. The main goal of these plants is to remove radio impurities from the liquid scintillator while increasing its optical attenuation length. Purification of liquid scintillator will be performed with a system combining alumina oxide, distillation, water extraction and steam (or N2 gas) stripping. Such a combined system will aim at obtaining a total attenuation length greater than 20 m at 430 nm, and a bulk radiopurity for 238U and 232Th in the 10-15 to 10-17 g/g range. The pilot plants commissioning and operation have also provided valuable information on the degree of reliability of their main components, which will be particularly useful for the design of the final full scale purification equipment for the JUNO liquid scintillator. This paper describe two of the five pilot plants since the Alumina Column, Fluor mixing and the Water Extraction plants are in charge of the Chinese part of the collaboration.

physics.ins-det↗

An adaptive stigmergy-based system for evaluating technological indicator dynamics in the context of smart specialization

Regional innovation is more and more considered an important enabler of welfare. It is no coincidence that the European Commission has started looking at regional peculiarities and dynamics, in order to focus Research and Innovation Strategies for Smart Specialization towards effective investment policies. In this context, this work aims to support policy makers in the analysis of innovation-relevant trends. We exploit a European database of the regional patent application to determine the dynamics of a set of technological innovation indicators. For this purpose, we design and develop a software system for assessing unfolding trends in such indicators. In contrast with conventional knowledge-based design, our approach is biologically-inspired and based on self-organization of information. This means that a functional structure, called track, appears and stays spontaneous at runtime when local dynamism in data occurs. A further prototyping of tracks allows a better distinction of the critical phenomena during unfolding events, with a better assessment of the progressing levels. The proposed mechanism works if structural parameters are correctly tuned for the given historical context. Determining such correct parameters is not a simple task since different indicators may have different dynamics. For this purpose, we adopt an adaptation mechanism based on differential evolution. The study includes the problem statement and its characterization in the literature, as well as the proposed solving approach, experimental setting and results.

cs.AI↗

Nanoseconds Timing System Based on IEEE 1588 FPGA Implementation

Clock synchronization procedures are mandatory in most physical experiments where event fragments are readout by spatially dislocated sensors and must be glued together to reconstruct key parameters (e.g. energy, interaction vertex etc.) of the process under investigation. These distributed data readout topologies rely on an accurate time information available at the frontend, where raw data are acquired and tagged with a precise timestamp prior to data buffering and central data collecting. This makes the network complexity and latency, between frontend and backend electronics, negligible within upper bounds imposed by the frontend data buffer capability. The proposed research work describes an FPGA implementation of IEEE 1588 Precision Time Protocol (PTP) that exploits the CERN Timing, Trigger and Control (TTC) system as a multicast messaging physical and data link layer. The hardware implementation extends the clock synchronization to the nanoseconds range, overcoming the typical accuracy limitations inferred by computers Ethernet based Local Area Network (LAN). Establishing a reliable communication between master and timing receiver nodes is essential in a message-based synchronization system. In the backend electronics, the serial data streams synchronization with the global clock domain is guaranteed by an hardware-based finite state machine that scans the bit period using a variable delay chain and finds the optimal sampling point. The validity of the proposed timing system has been proved in point-to-point data links as well as in star topology configurations over standard CAT-5e cables. The results achieved together with weaknesses and possible improvements are hereby detailed.

cs.NI↗

Long term monitoring of the optical background in the Capo Passero deep-sea site with the NEMO tower prototype

The NEMO Phase-2 tower is the first detector which was operated underwater for more than one year at the "record" depth of 3500 m. It was designed and built within the framework of the NEMO (NEutrino Mediterranean Observatory) project. The 380 m high tower was successfully installed in March 2013 80 km offshore Capo Passero (Italy). This is the first prototype operated on the site where the italian node of the KM3NeT neutrino telescope will be built. The installation and operation of the NEMO Phase-2 tower has proven the functionality of the infrastructure and the operability at 3500 m depth. A more than one year long monitoring of the deep water characteristics of the site has been also provided. In this paper the infrastructure and the tower structure and instrumentation are described. The results of long term optical background measurements are presented. The rates show stable and low baseline values, compatible with the contribution of 40K light emission, with a small percentage of light bursts due to bioluminescence. All these features confirm the stability and good optical properties of the site.

physics.ins-det↗

Measurement of the atmospheric muon depth intensity relation with the NEMO Phase-2 tower

The results of the analysis of the data collected with the NEMO Phase-2 tower, deployed at 3500 m depth about 80 km off-shore Capo Passero (Italy), are presented. Cherenkov photons detected with the photomultipliers tubes were used to reconstruct the tracks of atmospheric muons. Their zenith-angle distribution was measured and the results compared with Monte Carlo simulations. An evaluation of the systematic effects due to uncertainties on environmental and detector parameters is also included. The associated depth intensity relation was evaluated and compared with previous measurements and theoretical predictions. With the present analysis, the muon depth intensity relation has been measured up to 13 km of water equivalent.

physics.ins-det↗

Ultimate survival in anomalous psi(2S) decays

The hierarchy among the radiative $γ$($π^0$, $η$, $η^{\prime}$) decay channels for the $ψ^{\prime}$ looks quite different from the $J/ψ$ one. The fate of charm, namely an ultimate survival of on-shell $c \bar{c}$ intermediate states, might give us the clue for this new puzzle in exclusive charmonium decays. A similar self-preservation has already been invoked in the past to solve the so-called $ρπ$ puzzle.

hep-ph↗

Measurement of the atmospheric muon flux with the NEMO Phase-1 detector

The NEMO Collaboration installed and operated an underwater detector including prototypes of the critical elements of a possible underwater km3 neutrino telescope: a four-floor tower (called Mini-Tower) and a Junction Box. The detector was developed to test some of the main systems of the km3 detector, including the data transmission, the power distribution, the timing calibration and the acoustic positioning systems as well as to verify the capabilities of a single tridimensional detection structure to reconstruct muon tracks. We present results of the analysis of the data collected with the NEMO Mini-Tower. The position of photomultiplier tubes (PMTs) is determined through the acoustic position system. Signals detected with PMTs are used to reconstruct the tracks of atmospheric muons. The angular distribution of atmospheric muons was measured and results compared with Monte Carlo simulations.

astro-ph.IM↗