SearcharxivSearch

arXiv subjects

A. Molnar

Publications and source records attributed to A. Molnar.

10 recordsLinked to original sources

Characterization of the first full-size production for ePIC TOF layers

Low-Gain Avalanche Detectors (LGADs) are characterized by a fast rise time (500 ps) and extremely good time resolution (down to 17 ps). The intrinsic low granularity of LGADs and the large power consumption of readout chips for precise timing are problematic in near-future experiments such as e+e- Higgs factories (FCC-ee) and the ePIC detector at the Electron-Ion Collider. AC-coupled LGADs, where the readout metal is AC-coupled through an insulating oxide layer, could solve both issues at the same time thanks to the 100% fill factor and charge-sharing capabilities. Charge sharing between electrodes allows a hit position resolution well below the pitch/$\sqrt12$ of standard segmented detectors. At the same time, it relaxes the channel density and power consumption requirements of readout chips. Extensive laboratory characterization of AC-LGAD devices from the first full-size (up to 3x4 cm) production from HPK for ePIC will be shown in this contribution. Both pixel and strip geometry was produced and tested. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC.

physics.ins-det

Synchrotron light source focused X-ray detection with LGADs, AC-LGADs and TI-LGADs

The response of Low Gain Avalanche Diodes (LGADs), a type of thin silicon detector with internal gain, to X-rays of energies between 6-16~keV was characterized at the Stanford Synchrotron Radiation Lightsource (SSRL). The utilized beamline at SSRL was 7-2, with a nominal beam size of 30~$\mu$m, repetition rate of 500~MHz, and with an energy dispersion $\Delta E/E$ of $10^{-4}$. Multi-channel LGADs, AC-LGADs, and TI-LGADs of different thicknesses and gain layer configurations from Hamamatsu Photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested. The sensors were read out with a discrete component board and digitized with a fast oscilloscope or a CAEN fast digitizer. The devices' energy response, energy resolution, and time resolution were measured as a function of X-ray energy and position. The charge collection and multiplication mechanism were simulated using TCAD Sentaurus, and the results were compared with the collected data.

physics.ins-det

European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment

PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/\mu}$ to 1 part in $10^4$, improving the current experimental result $R_{e/\mu}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/\mu}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.

hep-ex

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13~$n_{eq}/cm^2$ fluence over the lifetime of the experiment.

physics.ins-det

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50~$\mu$m, 100~$\mu$m, 150~$\mu$m were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR) and energy linearity is an important property for particle ID capabilities.

physics.ins-det

Gain suppression study on LGADs at the CENPA tandem accelerator

Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge in the use of LGADs, studied by several research groups, is the gain suppression mechanism for large localized charge deposits. Using the CENPA Tandem accelerator at the University of Washington, the response of the LGADs to MeV-range energy deposits from a proton beam was studied. Two LGAD prototypes and a PIN diode were characterized, and the gain of the devices was determined as a function of bias voltage, incidence beam angle and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. %At the center of the experiment, a high-granularity active target (ATAR) will stop the pion and characterize its decay. A range of deposited charge from Minimum Ionizing Particle (MIP, few 10s of KeV) from positrons to several MeV from the stopping pions/muons is expected in PIONEER; the detection and separation of close-by hits in such a wide dynamic range will be a main challenge of the experiment. To achieve this goal, the gain suppression mechanism has to be understood fully.

physics.ins-det

Double hysteresis loops in proper uniaxial ferroelectrics

For the first time in a bulk proper uniaxial ferroelectrics, double antiferroelectric-like hysteresis loops have been observed in the case of Sn$_2$P$_2$S$_6$ crystal. The quantum anharmonic oscillator model was proposed for description of such polarization switching process. This phenomenon is related to three-well local potential of spontaneous polarization fluctuations at peculiar negative ratio of coupling constants which correspond to inter-site interaction in given sublattice and interaction between two sublattices of Sn$_2$P$_2$S$_6$ modeled crystal structure. Obtained data can be used for development of triple-level cell type memory technology.

cond-mat.mtrl-sci

Projected Entangled Pair States: Fundamental analytical and numerical limitations

Matrix Product States (MPS) and Projected Entangled Pair States (PEPS) are powerful analytical and numerical tools to assess quantum many-body systems in one and higher dimensions, respectively. While MPS are comprehensively understood, in PEPS fundamental questions, relevant analytically as well as numerically, remain open, such as how to encode symmetries in full generality, or how to stabilize numerical methods using canonical forms. Here, we show that these key problems, as well as a number of related questions, are algorithmically undecidable, that is, they cannot be fully resolved in a systematic way. Our work thereby exposes fundamental limitations to a full and unbiased understanding of quantum many-body systems using PEPS.

quant-ph

Valence fluctuations in Sn(Pb)$_2$P$_2$S$_6$ ferroelectrics

The valence fluctuations which are related to the charge disproportionation of phosphorous ions $P^{4+} + P^{4+}\rightarrow P^{3+} + P^{5+}$ are the origin of ferroelectric and quantum paraelectric states in Sn(Pb)$_2$P$_2$S$_6$ semiconductors. They involve recharging of SnPS$_3$ or PbPS$_3$ structural groups which could be represented as half-filled sites in the crystal lattice. Temperature-pressure phase diagram for Sn$_2$P$_2$S$_6$ compound and temperature-composition phase diagram for (Pb$_y$Sn$_{1-y}$)$_2$P$_2$S$_6$ mixed crystals, which include tricritical points and where a temperature of phase transitions decrease to 0 K, together with the data about some softening of low energy optic phonons and rise of dielectric susceptibility at cooling in quantum paraelectric state of Pb$_2$P$_2$S$_6$, are analyzed by GGA electron and phonon calculations and compared with electronic correlations models. The anharmonic quantum oscillators model is developed for description of phase diagrams and temperature dependence of dielectric susceptibility.

cond-mat.mtrl-sci

Observation of Kibble-Zurek behavior near the Lifshitz point in ferroelectrics with incommensurate phase

We have investigated non-equilibrium properties of proper uniaxial Sn$_2$P$_2$(Se$_x$S$_{1-x}$)$_6$ ferroelectrics with the Type II incommensurate phase above Lifshitz point $x_{\rm LP} \sim 0.28$. We measured dielectric susceptibility with cooling and heating rate ranging 0.002-0.1~K/min, and high-resolution ultrasound experiments and hypersound Brillouin scattering. For samples with $x \geqslant 0.28$ clear anomalies were observed at incommensurate second order transition ($T_i$) and at first order lock-in transition ($T_c$) in the regime of very slow cooling rate, whereas the intermediate IC phase is not observed when the rate is faster then 0.1~K/min. In general, increasing the cooling rate leads to smearing the anomaly at $T_c$. We explain this effect in terms of Kibble-Zurek model for non-equilibrium second order phase transitions. In the ferroelectrics with strongly nonlinear local potential cooling rate defines concentration of domain walls and their size: domain width decreases when cooling rate increases. At certain conditions the size of domain is comparable to the incommensurate phase modulation period, which lies in micrometer scale in the vicinity of Lifshitz point and leads to pinning of the modulation period by domain wall.

cond-mat.mtrl-sci