SearcharxivSearch

arXiv subjects

A. Mooser

Publications and source records attributed to A. Mooser.

At least 19 recordsLinked to original sources

Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.

physics.atom-ph

A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios

The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, $-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}}$ = $1.000\,000\,000\,003 (16)$, is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of $1.96\cdot10^{-27}\,$GeV (C$.$L$.$ 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP$_\text{cc}$) for antimatter to a level of $|\alpha_{g}-1| < 1.8 \cdot 10^{-7}$, and enables the first differential test of the WEP$_\text{cc}$ using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP$_\text{cc}$-violating coefficient to $|\alpha_{g,D}-1|<0.030$.

physics.atom-ph

Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature

We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.

physics.atom-ph

Ultra thin polymer foil cryogenic window for antiproton deceleration and storage

We present the design and characterisation of a cryogenic window based on an ultra-thin aluminised PET foil at T < 10K, which can withstand a pressure difference larger than 1bar at a leak rate < $1\times 10^{-9}$ mbar$\cdot$ l/s. Its thickness of approximately 1.7 $\mu$m makes it transparent to various types of particles over a broad energy range. To optimise the transfer of 100keV antiprotons through the window, we tested the degrading properties of different aluminium coated PET foils of thicknesses between 900nm and 2160nm, concluding that 1760nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature, and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of 7 holes with 1 mm diameter and will transmit up to 2.5% of the injected 100keV antiproton beam delivered by the AD/ELENA-facility of CERN.

physics.ins-det

BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

physics.ins-det

Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE

The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts in a trillion. In this contribution, we give an overview of the measurement campaign, and detail how its results are used to constrain nine spin-independent coefficients of the Standard-Model Extension in the proton and electron sector.

hep-ex

Direct measurement of the $^3$He$^+$ magnetic moments

Helium-3 has nowadays become one of the most important candidates for studies in fundamental physics [1, 2, 3], nuclear and atomic structure [4, 5], magnetometry and metrology [6] as well as chemistry and medicine [7, 8]. In particular, $^3$He nuclear magnetic resonance (NMR) probes have been proposed as a new standard for absolute magnetometry [6, 9]. This requires a high-accuracy value for the $^3$He nuclear magnetic moment, which, however, has so far been determined only indirectly and with a relative precision of $12$ parts per billon (p.p.b.) [10,11]. Here we investigate the $^3$He$^+$ ground-state hyperfine structure in a Penning trap to directly measure the nuclear $g$-factor of $^3$He$^+$ $g'_I=-4.255\, 099\, 606\, 9(30)_{stat}(17)_{sys}$, the zero-field hyperfine splitting $E_{\rm HFS}^{\rm exp}=-8\, 665\, 649\, 865.77(26)_{stat}(1)_{sys}$ Hz and the bound electron $g$-factor $g_e^\text{exp}=-2.002\, 177\, 415\, 79(34)_{stat}(30)_{sys}$. The latter is consistent with our theoretical value $g_e^\text{theo}=-2.002\, 177\, 416\, 252\, 23(39)$ based on parameters and fundamental constants from [12]. Our measured value for the $^3$He$^+$ nuclear $g$-factor allows for the determination of the $g$-factor of the bare nucleus $g_I=-4.255\, 250\, 699\, 7(30)_{stat}(17)_{sys}(1)_{theo}$ via our accurate calculation of the diamagnetic shielding constant [13] $\sigma_{^3He^+}=0.000\,035\,507\,38(3)$. This constitutes the first direct calibration for $^3$He NMR probes and an improvement of the precision by one order of magnitude compared to previous indirect results. The measured zero-field hyperfine splitting improves the precision by two orders of magnitude compared to the previous most precise value [14] and enables us to determine the Zemach radius [15] to $r_Z=2.608(24)$ fm.

physics.atom-ph

Sympathetic cooling schemes for separately trapped ions coupled via image currents

Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.

physics.atom-ph

Sympathetic cooling of a trapped proton mediated by an LC circuit

Efficient cooling of trapped charged particles is essential to many fundamental physics experiments, to high-precision metrology, and to quantum technology. Until now, sympathetic cooling has required close-range Coulomb interactions, but there has been a sustained desire to bring laser-cooling techniques to particles in macroscopically separated traps, extending quantum control techniques to previously inaccessible particles such as highly charged ions, molecular ions and antimatter. Here we demonstrate sympathetic cooling of a single proton using laser-cooled Be+ ions in spatially separated Penning traps. The traps are connected by a superconducting LC circuit that enables energy exchange over a distance of 9 cm. We also demonstrate the cooling of a resonant mode of a macroscopic LC circuit with laser-cooled ions and sympathetic cooling of an individually trapped proton, reaching temperatures far below the environmental temperature. Notably, as this technique uses only image-current interactions, it can be easily applied to an experiment with antiprotons, facilitating improved precision in matter-antimatter comparisons and dark matter searches.

physics.atom-ph

Direct limits on the interaction of antiprotons with axion-like dark matter

Astrophysical observations indicate that there is roughly five times more dark matter in the Universe than ordinary baryonic matter, with an even larger amount of the Universe's energy content due to dark energy. So far, the microscopic properties of these dark components have remained shrouded in mystery. In addition, even the five percent of ordinary matter in our Universe has yet to be understood, since the Standard Model of particle physics lacks any consistent explanation for the predominance of matter over antimatter. Inspired by these central problems of modern physics, we present here a direct search for interactions of antimatter with dark matter, and place direct constraints on the interaction of ultra-light axion-like particles $-$ one of the dark-matter candidates $-$ and antiprotons. If antiprotons exhibit a stronger coupling to these dark-matter particles than protons, such a CPT-odd coupling could provide a link between dark matter and the baryon asymmetry in the Universe. We analyse spin-flip resonance data acquired with a single antiproton in a Penning trap [Smorra et al., Nature 550, 371 (2017)] in the frequency domain to search for spin-precession effects from ultra-light axions with a characteristic frequency governed by the mass of the underlying particle. Our analysis constrains the axion-antiproton interaction parameter $f_a/C_{\overline{p}}$ to values greater than $0.1$ to $0.6$ GeV in the mass range from $2 \times 10^{-23}$ to $4 \times 10^{-17}\,$eV/$c^2$, improving over astrophysical antiproton bounds by up to five orders of magnitude. In addition, we derive limits on six combinations of previously unconstrained Lorentz-violating and CPT-violating terms of the non-minimal Standard Model Extension.

physics.atom-ph

Measurement of ultra-low heating rates of a single antiproton in a cryogenic Penning trap

We report on the first detailed study of motional heating in a cryogenic Penning trap using a single antiproton. Employing the continuous Stern-Gerlach effect we observe cyclotron quantum transition rates of 6(1) quanta/h and an electric field noise spectral density below $7.5(3.4)\times 10^{-20}\,\text{V}^{2}\text{m}^{-2} \text{Hz}^{-1}$, which corresponds to a scaled noise spectral density below $8.8(4.0)\times 10^{-12}\,\text{V}^{2}\text{m}^{-2}$, results which are more than two orders of magnitude smaller than those reported by other ion trap experiments.

physics.atom-ph

Sympathetic Cooling of Protons and Antiprotons with a Common Endcap Penning Trap

We present an experiment to sympathetically cool protons and antiprotons in a Penning trap by resonantly coupling the particles to laser cooled beryllium ions using a common endcap technique. Our analysis shows that preparation of (anti)protons at mK temperatures on timescales of tens of seconds is feasible. Successful implementation of the technique will have immediate and significant impact on high-precision comparisons of the fundamental properties of protons and antiprotons. This in turn will provide some of the most stringent tests of the fundamental symmetries of the Standard Model.

physics.atom-ph

Observation of individual spin quantum transitions of a single antiproton

We report on the detection of individual spin quantum transitions of a single trapped antiproton in a Penning trap. The spin-state determination, which is based on the unambiguous detection of axial frequency shifts in presence of a strong magnetic bottle, reaches a fidelity of 92.1$\%$. Spin-state initialization with $>99.9\%$ fidelity and an average initialization time of 24 min are demonstrated. This is a major step towards an antiproton magnetic moment measurement with a relative uncertainty on the part-per-billion level.

physics.atom-ph

Highly-sensitive superconducting circuits at ~700 kHz with tunable quality factors for image-current detection of single trapped antiprotons

We developed highly-sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550$\sim$800$\,$kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500$\,$000, which corresponds to a factor of 10 improvement compared to our previously used solenoidal designs. Connected to ultra-low noise amplifiers and the trap system, signal-to-noise-ratios of 30$\,$dB at quality factors of > 20$\,$000 are achieved. In addition, we have developed a superconducting switch which allows continuous tuning of the detector's quality factor, and to sensitively tune the particle-detector interaction. This allowed us to improve frequency resolution at constant averaging time, which is crucial for single antiproton spin-transition spectroscopy experiments, as well as improved measurements of the proton-to-antiproton charge-to-mass ratio.

physics.ins-det

BASE - The Baryon Antibaryon Symmetry Experiment

The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing the magnetic moments of the proton and the antiproton with high precision. Using single particles in a Penning trap, the proton/antiproton $g$-factors, i.e. the magnetic moment in units of the nuclear magneton, are determined by measuring the respective ratio of the spin-precession frequency to the cyclotron frequency. The spin precession frequency is measured by non-destructive detection of spin quantum transitions using the continuous Stern-Gerlach effect, and the cyclotron frequency is determined from the particle's motional eigenfrequencies in the Penning trap using the invariance theorem. By application of the double Penning-trap method we expect that in our measurements a fractional precision of $\delta g/g$ 10$^{-9}$ can be achieved. The successful application of this method to the antiproton will represent a factor 1000 improvement in the fractional precision of its magnetic moment. The BASE collaboration has constructed and commissioned a new experiment at the Antiproton Decelerator (AD) of CERN. This article describes and summarizes the physical and technical aspects of this new experiment.

physics.atom-ph

Direct high-precision measurement of the magnetic moment of the proton

The spin-magnetic moment of the proton $μ_p$ is a fundamental property of this particle. So far $μ_p$ has only been measured indirectly, analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here, we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin-transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in units of the nuclear magneton $μ_p=2.792847350(9)μ_N$. This measurement outperforms previous Penning trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty year old indirect measurement, in which significant theoretical bound state corrections were required to obtain $μ_p$, by a factor of 3. By application of this method to the antiproton magnetic moment $μ_{\bar{p}}$ the fractional precision of the recently reported value can be improved by a factor of at least 1000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.

physics.atom-ph

The magnetic moments of the proton and the antiproton

Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin state. Based on this success the proton magnetic moment $\mu_p$ was measured with ppm precision in a Penning trap with a superimposed magnetic field inhomogeneity. An improvement by an additional factor of 1000 in precision is possible by application of the so-called double Penning trap technique. In a recent paper we reported the first demonstration of this method with a single trapped proton, which is a major step towards the first direct high-precision measurement of $\mu_p$. The techniques required for the proton can be directly applied to measure the antiproton magnetic moment $\mu_{\bar{p}}$. An improvement in precision of $\mu_{\bar{p}}$ by more than three orders of magnitude becomes possible, which will provide one of the most sensitive tests of CPT invariance. To achieve this research goal we are currently setting up the Baryon Antibaryon Symmetry Experiment (BASE) at the antiproton decelerator (AD) of CERN.

physics.atom-ph

Towards a high-precision measurement of the antiproton magnetic moment

The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success, which has been achieved with our apparatus at the University of Mainz, we demonstrated recently the first application of the so called double Penning-trap method with a single proton. This is a major step towards a measurement of the proton magnetic moment with ppb precision. To apply this method to a single trapped antiproton our collaboration is currently setting up a companion experiment at the antiproton decelerator of CERN. This effort is recognized as the Baryon Antibaryon Symmetry Experiment (BASE). A comparison of both magnetic moment values will provide a stringent test of CPT invariance with baryons.

physics.atom-ph