SearcharxivSearch

arXiv subjects

A. Olin

Publications and source records attributed to A. Olin.

At least 19 recordsLinked to original sources

Acceleration of positive muons by a radio-frequency cavity

Acceleration of positive muons from thermal energy to $100~$keV has been demonstrated. Thermal muons were generated by resonant multi-photon ionization of muonium atoms emitted from a sheet of laser-ablated aerogel. The thermal muons were first electrostatically accelerated to $5.7~$keV, followed by further acceleration to 100 keV using a radio-frequency quadrupole. The transverse normalized emittance of the accelerated muons in the horizontal and vertical planes were $0.85 \pm 0.25 ~\rm{(stat.)}~^{+0.22}_{-0.13} ~\rm{(syst.)}~\pi~$mm$\cdot$mrad and $0.32\pm 0.03~\rm{(stat.)} ^{+0.05}_{-0.02} ~\rm{(syst.)}~\pi~$mm$\cdot$mrad, respectively. The measured emittance values demonstrated phase space reduction by a factor of $2.0\times 10^2$ (horizontal) and $4.1\times 10^2$ (vertical) allowing good acceleration efficiency. These results pave the way to realize the first-ever muon accelerator for a variety of applications in particle physics, material science, and other fields.

physics.acc-ph

Limit on the Electric Charge of Antihydrogen

The ALPHA collaboration has successfully demonstrated the production and the confinement of cold antihydrogen, $\overline{\mathrm{H}}$. An analysis of trapping data allowed a stringent limit to be placed on the electric charge of the simplest antiatom. Charge neutrality of matter is known to a very high precision, hence a neutrality limit of $\overline{\mathrm{H}}$ provides a test of CPT invariance. The experimental technique is based on the measurement of the deflection of putatively charged $\overline{\mathrm{H}}$ in an electric field. The tendency for trapped $\overline{\mathrm{H}}$ atoms to be displaced by electrostatic fields is measured and compared to the results of a detailed simulation of $\overline{\mathrm{H}}$ dynamics in the trap. An extensive survey of the systematic errors is performed, with particular attention to those due to the silicon vertex detector, which is the device used to determine the $\overline{\mathrm{H}}$ annihilation position. The limit obtained on the charge of the $\overline{\mathrm{H}}$ atom is \mbox{$ Q = (-1.3\pm1.8\pm0.4)\times10^{-8}$}, representing the first precision measurement with $\overline{\mathrm{H}}$.

physics.atom-ph

Study of muonium emission from laser-ablated silica aerogel

The emission of muonium ($μ^+e^-$) atoms into vacuum from silica aerogel with laser ablation on its surface was studied with various ablation structures at room temperature using the subsurface muon beams at TRIUMF and Japan Proton Accelerator Research Complex (J-PARC). Laser ablation was applied to produce holes or grooves with typical dimensions of a few hundred $μ$m to a few mm, except for some extreme conditions. The measured emission rate tends to be higher for larger fractions of ablation opening and for shallower depths. More than a few ablation structures reach the emission rates similar to the highest achieved in the past measurements. The emission rate is found to be stable at least for a couple of days. Measurements of spin precession amplitudes for the produced muonium atoms and remaining muons in a magnetic field determine a muonium formation fraction of $(65.5 \pm 1.8)$%. The precession of the polarized muonium atoms is also observed clearly in vacuum. A projection of the emission rates measured at TRIUMF to the corresponding rates at J-PARC is demonstrated taking the different beam condition into account reasonably.

physics.ins-det

Charged particle spectra from $μ^{-}$ capture on Al

Published data on the emission of charged particles following nuclear muon capture are extremely limited. In addition to its interest as a probe of the nuclear response, these data are important for the design of some current searches for lepton flavor violation. This work presents momentum spectra of protons and deuterons following $μ^{-}$ capture in aluminum. It is the first measurement of a muon capture process performed with a tracking spectrometer. A precision of better than 10% over the momentum range of 100--190 MeV/c for protons is obtained; for deuterons of 145--250 MeV/c the precision is better than 20%. The observed partial yield of protons with emission momenta above 80 MeV/c (kinetic energy 3.4 MeV) is $0.0322\pm0.0007(\text{stat})\pm0.0022(\text{syst})$ per capture, and for deuterons above 130 MeV/c (4.5 MeV) it is $0.0122\pm0.0009(\text{stat})\pm0.0006(\text{syst})$. Extrapolating to total yields gives $0.045\pm0.001(\text{stat})\pm0.003(\text{syst}) \pm 0.001(\text{extrapolation})$ per capture for protons and $0.018\pm0.001(\text{stat})\pm0.001(\text{syst})\pm 0.002(\text{extrapolation})$ for deuterons, which are the most precise measurements of these quantities to date.

hep-ex

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_μ = (g-2)/2$, and the muon electric dipole moment (EDM) $d_μ$ at the J-PARC muon facility. The goal of our experiment is to measure $a_μ$ and $d_μ$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_μ$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det

A search for two body muon decay signals

Lepton family number violation is tested by searching for $μ^+\to e^+X^0$ decays among the 5.8$\times 10^8$ positive muon decay events analyzed by the TWIST collaboration. Limits are set on the production of both massless and massive $X^0$ bosons. The large angular acceptance of this experiment allows limits to be placed on anisotropic $μ^+\to e^+X^0$ decays, which can arise from interactions violating both lepton flavor and parity conservation. Branching ratio limits of order $10^{-5}$ are obtained for bosons with masses of 13 - 80 MeV/c$^2$ and with different decay asymmetries. For bosons with masses less than 13 MeV/c$^{2}$ the asymmetry dependence is much stronger and the 90% limit on the branching ratio varies up to $5.8 \times 10^{-5}$. This is the first study that explicitly evaluates the limits for anisotropic two body muon decays.

hep-ex

Enhancement of muonium emission rate from silica aerogel with a laser ablated surface

Emission of muonium ($μ^+e^-$) atoms from a laser-processed aerogel surface into vacuum was studied for the first time. Laser ablation was used to create hole-like regions with diameter of about 270$~μ$m in a triangular pattern with hole separation in the range of 300--500$~μ$m. The emission probability for the laser-processed aerogel sample is at least eight times higher than for a uniform one.

physics.ins-det

In situ electromagnetic field diagnostics with an electron plasma in a Penning-Malmberg trap

We demonstrate a novel detection method for the cyclotron resonance frequency of an electron plasma in a Penning-Malmberg trap. With this technique, the electron plasma is used as an in situ diagnostic tool for measurement of the static magnetic field and the microwave electric field in the trap. The cyclotron motion of the electron plasma is excited by microwave radiation and the temperature change of the plasma is measured non-destructively by monitoring the plasma's quadrupole mode frequency. The spatially-resolved microwave electric field strength can be inferred from the plasma temperature change and the magnetic field is found through the cyclotron resonance frequency. These measurements were used extensively in the recently reported demonstration of resonant quantum interactions with antihydrogen.

physics.plasm-ph

Measurement of muonium emission from silica aerogel

Emission of muonium ($μ^{+}e^{-}$) atoms from silica aerogel into vacuum was observed. Characteristics of muonium emission were established from silica aerogel samples with densities in the range from 29 mg cm$^{-3}$ to 178 mg cm$^{-3}$. Spectra of muonium decay times correlated with distances from the aerogel surfaces, which are sensitive to the speed distributions, follow general features expected from a diffusion process, while small deviations from a simple room-temperature thermal diffusion model are identified. The parameters of the diffusion process are deduced from the observed yields.

physics.atom-ph

Precision muon decay measurements and improved constraints on the weak interaction

The TWIST Collaboration has completed its measurement of the three muon decay parameters ρ, δ, and P_μξ. This paper describes our determination of ρ, which governs the shape of the overall momentum spectrum, and δ, which controls the momentum dependence of the parity-violating decay asymmetry. The results are ρ=0.74977\pm 0.00012(stat.)\pm 0.00023(syst.) and δ= 0.75049\pm 0.00021(stat.)\pm 0.00027(syst.). These are consistent with the value of 3/4 given for both parameters in the standard model, and each is over a factor of 10 more precise than the measurements published prior to TWIST. Our final results on ρ, δ, and P_μξhave been incorporated into a new global analysis of all available muon decay data, resulting in improved model-independent constraints on the possible weak interactions of right-handed particles.

hep-ex

Antihydrogen and mirror-trapped antiproton discrimination: Discriminating between antihydrogen and mirror-trapped antiprotons in a minimum-B trap

Recently, antihydrogen atoms were trapped at CERN in a magnetic minimum (minimum-B) trap formed by superconducting octupole and mirror magnet coils. The trapped antiatoms were detected by rapidly turning off these magnets, thereby eliminating the magnetic minimum and releasing any antiatoms contained in the trap. Once released, these antiatoms quickly hit the trap wall, whereupon the positrons and antiprotons in the antiatoms annihilated. The antiproton annihilations produce easily detected signals; we used these signals to prove that we trapped antihydrogen. However, our technique could be confounded by mirror-trapped antiprotons, which would produce seemingly-identical annihilation signals upon hitting the trap wall. In this paper, we discuss possible sources of mirror-trapped antiprotons and show that antihydrogen and antiprotons can be readily distinguished, often with the aid of applied electric fields, by analyzing the annihilation locations and times. We further discuss the general properties of antiproton and antihydrogen trajectories in this magnetic geometry, and reconstruct the antihydrogen energy distribution from the measured annihilation time history.

physics.atom-ph

Precise measurement of parity violation in polarized muon decay

We present a new high precision measurement of parity violation in the weak interaction, using polarized muon decay. The TWIST collaboration has measured $P_μ^πξ$, where $P_μ^π$ is the polarization of the muon in pion decay and $ξ$ describes the intrinsic asymmetry in muon decay. We find $P_μ^πξ= 1.00084 \pm 0.00029\,(\textrm{stat.})_{-0.00063}^{+0.00165}\,(\textrm{syst.})$, in good agreement with the standard model prediction of $P_μ^π=ξ=1$. Our result is a factor of 7 more precise than the pre-TWIST value, setting new limits in left-right symmetric electroweak extensions to the standard model.

hep-ex

Confinement of antihydrogen for 1000 seconds

Atoms made of a particle and an antiparticle are unstable, usually surviving less than a microsecond. Antihydrogen, made entirely of antiparticles, is believed to be stable, and it is this longevity that holds the promise of precision studies of matter-antimatter symmetry. We have recently demonstrated trapping of antihydrogen atoms by releasing them after a confinement time of 172 ms. A critical question for future studies is: how long can anti-atoms be trapped? Here we report the observation of anti-atom confinement for 1000 s, extending our earlier results by nearly four orders of magnitude. Our calculations indicate that most of the trapped anti-atoms reach the ground state. Further, we report the first measurement of the energy distribution of trapped antihydrogen which, coupled with detailed comparisons with simulations, provides a key tool for the systematic investigation of trapping dynamics. These advances open up a range of experimental possibilities, including precision studies of CPT symmetry and cooling to temperatures where gravitational effects could become apparent.

physics.atom-ph

Centrifugal separation and equilibration dynamics in an electron-antiproton plasma

Charges in cold, multiple-species, non-neutral plasmas separate radially by mass, forming centrifugally-separated states. Here, we report the first detailed measurements of such states in an electron-antiproton plasma, and the first observations of the separation dynamics in any centrifugally-separated system. While the observed equilibrium states are expected and in agreement with theory, the equilibration time is approximately constant over a wide range of parameters, a surprising and as yet unexplained result. Electron-antiproton plasmas play a crucial role in antihydrogen trapping experiments.

physics.plasm-ph

Alpha Antihydrogen Experiment

ALPHA is an experiment at CERN, whose ultimate goal is to perform a precise test of CPT symmetry with trapped antihydrogen atoms. After reviewing the motivations, we discuss our recent progress toward the initial goal of stable trapping of antihydrogen, with some emphasis on particle detection techniques.

nucl-ex

New Experimental Constraints for the Standard Model from Muon Decay

The TWIST Collaboration has completed a new measurement of the energy-angle spectrum of positrons from the decay of highly polarized muons. A simultaneous measurement of the muon decay parameters ρ, δ, and (P_μ)ξ tests the Standard Model (SM) in a purely leptonic process and provides improved limits for relevant extensions to the SM. Specifically, for the generalized left-right symmetric model |(g_R/g_L)ζ|<0.020 and (g_L/g_R)m_2> 578 GeV/c^2, both 90% C.L.

hep-ex

Evaporative Cooling of Antiprotons to Cryogenic Temperatures

We report the application of evaporative cooling to clouds of trapped antiprotons, resulting in plasmas with measured temperature as low as 9~K. We have modeled the evaporation process for charged particles using appropriate rate equations. Good agreement between experiment and theory is observed, permitting prediction of cooling efficiency in future experiments. The technique opens up new possibilities for cooling of trapped ions and is of particular interest in antiproton physics, where a precise \emph{CPT} test on trapped antihydrogen is a long-standing goal.

physics.plasm-ph

Calibration of the TWIST high-precision drift chambers

A method for the precise measurement of drift times for the high-precision drift chambers used in the TWIST detector is described. It is based on the iterative correction of the space-time relationships by the time residuals of the track fit, resulting in a measurement of the effective drift times. The corrected drift time maps are parametrised individually for each chamber using spline functions. Biases introduced by the reconstruction itself are taken into account as well, making it necessary to apply the procedure to both data and simulation. The described calibration is shown to improve the reconstruction performance and to extend significantly the physics reach of the experiment.

physics.ins-det