SearcharxivSearch

arXiv subjects

A. Ordine

Publications and source records attributed to A. Ordine.

9 recordsLinked to original sources

Clarifying the Radiative Decay of the Hoyle State with Charged-Particle Spectroscopy

A detailed knowledge of the decay properties of the so called Hoyle state in the $^{12}$C nucleus ($E_x=7.654$ MeV, $0^+$) is required to calculate the rate at which carbon is forged in typical red-giant stars. This paper reports on a new almost background-free measurement of the radiative decay branching ratio of the Hoyle state using advanced charged particle coincidence techniques. The exploitation, for the first time in a similar experiment, of a bidimensional map of the coincidence efficiency allows to reach an unitary value and, consequently, to strongly reduce sources of systematic uncertainties. The present results suggest a value of the radiative branching ratio of $\Gamma_{rad}/\Gamma_{tot}=4.2(6)\cdot10^{-4}$. This finding helps to resolve the tension between recent data published in the literature.

nucl-ex

First results from the INDRA-FAZIA apparatus on isospin diffusion in $^{58,64}$Ni+$^{58,64}$Ni systems at Fermi energies

An investigation of the isospin equilibration process in the reactions $^{58,64}$Ni+$^{58,64}$Ni at two bombarding energies in the Fermi regime ($32\,$MeV/nucleon and $52\,$MeV/nucleon) is presented. Data have been acquired during the first experimental campaign of the coupled INDRA-FAZIA apparatus in GANIL. Selecting from peripheral to semi-central collisions, both the neutron content of the quasiprojectile residue and that of the light ejectiles coming from the quasiprojectile evaporation have been used as probes of the dynamical process of isospin diffusion between projectile and target for the asymmetric systems. The isospin transport ratio technique has been employed. The relaxation of the initial isospin imbalance with increasing centrality has been clearly evidenced. The isospin equilibration appears stronger for the reactions at $32\,$MeV/nucleon, as expected due to the longer projectile-target interaction time than at $52\,$MeV/nucleon. Coherent indications of isospin equilibration come from the quasiprojectile residue characteristics and from particles ascribed to the quasiprojectile decay.

nucl-ex

The FAZIA setup: a review on the electronics and the mechanical mounting

In this paper the technological aspects of the FAZIA array will be explored. After a productive commissioning phase, FAZIA blocks started to measure and give very useful data to explore the physics of Fermi energy heavy-ion reactions. This was possible thanks to many technical measures and innovations developed in the commissioning phase and tuned during the first experimental campaigns. This paper gives a detailed description of the present status of the FAZIA setup from the electronic and mechanical point of view, trying also to trace a path for new improvements and refinements of the apparatus.

physics.ins-det

High precision probe of the fully sequential decay width of the Hoyle state in $^{12}$C

The decay path of the Hoyle state in $^{12}$C ($E_x=7.654\textrm{MeV}$) has been studied with the $^{14}\textrm{N}(\textrm{d},α_2)^{12}\textrm{C}(7.654)$ reaction induced at $10.5\textrm{MeV}$. High resolution invariant mass spectroscopy techniques have allowed to unambiguously disentangle direct and sequential decays of the state passing through the ground state of $^{8}$Be. Thanks to the almost total absence of background and the attained resolution, a fully sequential decay contribution to the width of the state has been observed. The direct decay width is negligible, with an upper limit of $0.043\%$ ($95\%$ C.L.). The precision of this result is about a factor $5$ higher than previous studies. This has significant implications on nuclear structure, as it provides constraints to $3$-$α$ cluster model calculations, where higher precision limits are needed.

nucl-ex

Energy measurement and fragment identification using digital signals from partially depleted Si detectors

A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the DE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector whose doping uniformity is not good enough for isotopic identification at full depletion.

physics.ins-det

GARFIELD + RCo Digital Upgrade: a Modern Set-up for Mass and Charge Identification of Heavy Ion Reaction Products

An upgraded GARFIELD + Ring Counter (RCo) apparatus is presented with improved performances as far as electronics and detectors are concerned. On one side fast sampling digital read out has been extended to all detectors, allowing for an important simplification of the signal processing chain together with an enriched extracted information. On the other side a relevant improvement has been made in the forward part of the setup (RCo): an increased granularity of the CsI(Tl) crystals and a higher homogeneity in the silicon detector resistivity. The renewed performances of the GARFIELD + RCo array make it suitable for nuclear reaction measurements both with stable and with Radioactive Ion Beams (RIB), like the ones foreseen for the SPES facility, where the Physics of Isospin can be studied.

physics.ins-det

The european FAZIA initiative: a high-performance digital telescope array for heavy-ion studies

The european Fazia collaboration aims at building a new modular array for charged product identification to be employed for heavy-ion studies. The elementary module of the array is a Silicon-Silicon-CsI telescope, optimized for ion identification also via pulse shape analysis. The achievement of top performances imposes specific electronics which has been developed by FAZIA and features high quality charge and current preamplifiers, coupled to fully digital front-end. During the initial R&D phase, original and novel solutions have been tested in prototypes, obtaining unprecedented ion identification capabilities. FAZIA is now constructing a demonstrator array consisting of about two hundreds telescopes arranged in a compact and transportable configuration. In this contribution, we mainly summarize some aspects studied by FAZIA to improve the ion identification. Then we will briefly discuss the FAZIA program centered on experiments to be done with the demonstrator. First results on the isospin dynamics obtained with a reduced set-up demonstrate well the performance of the telescope and represent a good starting point towards future investigations with both stable and exotic beams.

physics.ins-det

Isotope analysis in central heavy ion collisions at intermediate energies

Symmetry energy is a key quantity in the study of the equation of state of asymmetric nuclear matter. Heavy ion collisions at low and intermediate energies, performed at Laboratori Nazionali di Legnaro and Laboratori Nazionali del Sud, can be used to extract information on the symmetry energy coefficient Csym, which is currently poorly known but relevant both for astrophysics and for structure of exotic nuclei.

nucl-ex

First direct measurement of the total cross section of 12C(alpha,gamma)16O

The total cross section of 12C(alpha,gamma)16O was measured for the first time by a direct and ungated detection of the 16O recoils. This measurement in inverse kinematics using the recoil mass separator ERNA in combination with a windowless He gas target allowed to collect data with high precision in the energy range E=1.9 to 4.9 MeV. The data represent new information for the determination of the astrophysical S(E) factor.

nucl-ex