Searcharxiv⌕ Search

arXiv subjects

A. Pascual Laguna

Publications and source records attributed to A. Pascual Laguna.

2 recordsLinked to original sources

DESHIMA 2.0: A 200-400 GHz Ultra-wideband Integrated Superconducting Spectrometer

DESHIMA (Deep Spectroscopic HIgh-redshift MApper) is a broadband integrated superconducting spectrometer (ISS) for millimeter (mm) / sub-millimeter (sub-mm) wave astronomy based on Kinetic Inductance Detectors (KIDs). This paper describes characterization of DESHIMA 2.0 in laboratory settings. The instrument features NbTiN superconducting microstrip (MS) filters with low-loss a-SiC:H dielectric and an ultra-wideband leaky-wave antenna. A laboratory setup was designed, incorporating the cryostat housing cryogenic optics and ISS chip comprising 339 KIDs connected to MS filters tuned for (sub-)mm wave frequencies. Room-temperature mirrors on a hexapod stage allowed precise positioning and alignment of optical elements. The sky-position chopper was positioned on a motor-controlled stage for fine-tuned control over its position and alignment. Thanks to the multiplexing capability of KIDs, we could simultaneously measure multiple performance metrics across the entire frequency range. We showed that DESHIMA 2.0 achieved significant improvements in performance compared to its predecessor (DESHIMA 1.0): measured instantaneous frequency coverage was 200$-$400 GHz with a mean filter $Q_{filter}$ of $340 \pm 50$; instrument efficiency reached $\sim8$ \%, indicating 4 times wider band coverage and 4 times higher sensitivity. The yield rate for MS filters exceeded 98 \%. The estimated aperture efficiency from measured beam patterns agreed well with the designed value of approximately 70 \%. The telescope far-field beam patterns calculated from measured beam patterns also exhibited good agreement with design specifications. We also demonstrated validity of a new method of absolute frequency calibration using the data from beam pattern measurement.

astro-ph.IM↗

Ultra-sensitive Super-THz Microwave Kinetic Inductance Detectors for future space telescopes

Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in observing speed of many orders of magnitude. A spectroscopic instrument on such an observatory requires large arrays of detectors with a sensitivity expressed as a noise equivalent power NEP = 3 $\times 10^{-20}$ $W\surd{Hz}$. We present the design, fabrication, and characterisation of microwave kinetic inductance detectors (MKIDs) for this frequency range reaching the required sensitivity. The devices are based on thin-film NbTiN resonators which use lens-antenna coupling to a submicron-width aluminium transmission line at the shorted end of the resonator where the radiation is absorbed. We optimised the MKID geometry for a low NEP by using a small aluminium volume of $\approx$ 1$μm^3$ and fabricating the aluminium section on a very thin (100 nm) SiN membrane. Both methods of optimisation also reduce the effect of excess noise by increasing the responsivity of the device, which is further increased by reducing the parasitic geometrical inductance of the resonator. We measure the sensitivity of eight MKIDs with respect to the power absorbed in the detector using a thermal calibration source filtered in a narrow band around 1.55 THz. We obtain a NEP$_{exp}(P_{abs})\:=\:3.1\pm0.9\times10^{-20}\:W\surd{Hz}$ at a modulation frequency of 200 Hz averaged over all measured MKIDs. The NEP is limited by quasiparticle trapping. The measured sensitivity is sufficient for spectroscopic observations from future, actively cooled space-based observatories. Moreover, the presented device design and assembly can be adapted for frequencies up to $\approx$ 10 THz and can be readily implemented in kilopixel arrays.

astro-ph.IM↗