Searcharxiv⌕ Search

arXiv subjects

A. Pellegrino

Publications and source records attributed to A. Pellegrino.

5 recordsLinked to original sources

A Radio-quiet AGN as a candidate counterpart to neutrino event IceCube-200615A

Follow-up observations of neutrino events have been a promising method for identifying sources of very-high-energy cosmic rays. Neutrinos are unambiguous tracers of hadronic interactions and cosmic rays. On June 15, 2020, IceCube detected a neutrino event with an 82.8% probability of being astrophysical in origin. To identify the astrophysical source of the neutrino, we used X-ray tiling observations to identify potential counterpart sources. We performed additional multiwavelength follow-up with NuSTAR and the VLA in order to construct a broadband spectral energy distribution (SED) of the most likely counterpart. From the SED, we calculate an estimate for the neutrinos we expect to detect from the source. While the source does not have a high predicted neutrino flux, it is still a plausible neutrino emitter. It is important to note that the other bright X-ray candidate sources consistent with the neutrino event are also radio-quiet AGN. A statistical analysis shows that 1RXS J093117.6+033146 is the most likely counterpart (87.5%) if the neutrino is cosmic in origin and if it is among X-ray detectable sources. This results adds to previous results suggesting a connection between radio-quiet AGN and IceCube neutrino events.

astro-ph.HE↗

Radiation Tolerance of the LHCb Outer Tracker: in the Lab and in the Forward Region at the LHC

During the detector construction phase between 2004 and 2006, it was discovered that the LHCb Outer Tracker (OT) detector suffered from gain loss after irradiation in the laboratory at moderate intensities. Under irradiation an insulating layer was formed on the anode wire. The aging was caused by contamination of the counting gas due to outgassing of the glue used in construction namely araldite AY103-1. The gain loss was concentrated upstream the gas flow, and at moderate irradiation intensity only. The aging rate was reduced by longterm flushing and by the addition of a few percent of O2 to the gas mixture. Furthermore, applying a large positive high voltage (beyond the amplification regime) has shown to remove the insulating deposits without damaging the wire surface. This paper presents the history of the developments together with the characteristics and the culprit of the aging phenomenon and the resulting detector performance in situ.

physics.ins-det↗

Improved performance of the LHCb Outer Tracker in LHC Run 2

The LHCb Outer Tracker is a gaseous detector covering an area of $5\times 6 m^2$ with 12 double layers of straw tubes. The performance of the detector is presented based on data of the LHC Run 2 running period from 2015 and 2016. Occupancies and operational experience for data collected in $p p$, pPb and PbPb collisions are described. An updated study of the ageing effects is presented showing no signs of gain deterioration or other radiation damage effects. In addition several improvements with respect to LHC Run 1 data taking are introduced. A novel real-time calibration of the time-alignment of the detector and the alignment of the single monolayers composing detector modules are presented, improving the drift-time and position resolution of the detector by 20\%. Finally, a potential use of the improved resolution for the timing of charged tracks is described, showing the possibility to identify low-momentum hadrons with their time-of-flight.

physics.ins-det↗

Performance of the LHCb Outer Tracker

The LHCb Outer Tracker is a gaseous detector covering an area of 5x6 m2 with 12 double layers of straw tubes. The detector with its services are described together with the commissioning and calibration procedures. Based on data of the first LHC running period from 2010 to 2012, the performance of the readout electronics and the single hit resolution and efficiency are presented. The efficiency to detect a hit in the central half of the straw is estimated to be 99.2%, and the position resolution is determined to be approximately 200 um. The Outer Tracker received a dose in the hottest region corresponding to 0.12 C/cm, and no signs of gain deterioration or other ageing effects are observed.

physics.ins-det↗

Application of vertex and mass constraints in track-based alignment

The software alignment of planar tracking detectors using samples of charged particle trajectories may lead to global detector distortions that affect vertex and momentum resolution. We present an alignment procedure that constrains such distortions by making use of samples of decay vertices reconstructed from two or more trajectories and putting constraints on their invariant mass. We illustrate the method by using a sample of invariant-mass constrained vertices from D^0 --> K^- pi^+ decays to remove a curvature bias in the LHCb spectrometer.

physics.ins-det↗