SearcharxivSearch

arXiv subjects

A. Preite Martinez

Publications and source records attributed to A. Preite Martinez.

11 recordsLinked to original sources

Multi-scale analysis of lung computed tomography images

A computer-aided detection (CAD) system for the identification of lung internal nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 project. The three modules of our lung CAD system, a segmentation algorithm for lung internal region identification, a multi-scale dot-enhancement filter for nodule candidate selection and a multi-scale neural technique for false positive finding reduction, are described. The results obtained on a dataset of low-dose and thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

physics.med-ph

A hydrodynamical analysis of the steady-state shock model

In this article some of the hydrodynamical (HD) aspects of steady shocks as described by the steady-state shock model are reviewed and discussed. It is found that, at least in some of the contexts in which the steady-state model is used, the steady-state assumption cannot be satisfied. Moreover, the main result of the present work is that even if the assumptions on steadiness and on the geometry are fully satisfied, serious limitations in the application of the model are found: (i) in the absence of down-stream boundary conditions the model is not related to the physical process(es) that originate the shock, (ii) matter shocked during the presumed phase of steadiness of the shock is not hydrodynamically interacting with previously shocked matter, and (iii) the steady-state model assumes that the flow is stable against perturbations. Furthermore, even if boundary conditions were assumed, the link between the steady model and the astrophysical context would not be strictly speaking the correct HD link. Time-dependent HD computations in different astrophysical contexts (e.g. SNRs and molecular shocks) show that the steady-state approximation is inadequate to describe these post-shock structures. Based on the HD limitations of the steady-state model, it is advised that the model be used to describe post-shock structures only in those astrophysical contexts where full time-dependent HD models have already positively tested the steadiness of the flow. Alternatively, it is suggested to replace the steady-state model either with time-dependent HD models, or with less problematic approximations.

astro-ph

Automated detection of lung nodules in low-dose computed tomography

A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (~300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan

physics.med-ph

An automated system for lung nodule detection in low-dose computed tomography

A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images was developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The results obtained on the collected database of low-dose thin-slice CT scans are shown in terms of free response receiver operating characteristic (FROC) curves and discussed.

physics.med-ph

Lung nodule detection in low-dose and high-resolution CT scans

We are developing a computer-aided detection (CAD) system for the identification of small pulmonary nodules in screening CT scans. The main modules of our system, i.e. a dot-enhancement filter for nodule candidate selection and a neural classifier for false positive finding reduction, are described. The preliminary results obtained on the so-far collected database of lung CT are discussed.

physics.med-ph

Lung Nodule Detection in Screening Computed Tomography

A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.

physics.med-ph

Computer-aided detection of pulmonary nodules in low-dose CT

A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical CT images with 1.25 mm slice thickness is being developed in the framework of the INFN-supported MAGIC-5 Italian project. The basic modules of our lung-CAD system, a dot enhancement filter for nodule candidate selection and a voxel-based neural classifier for false-positive finding reduction, are described. Preliminary results obtained on the so-far collected database of lung CT scans are discussed.

physics.med-ph

A scalable system for microcalcification cluster automated detection in a distributed mammographic database

A computer-aided detection (CADe) system for microcalcification cluster identification in mammograms has been developed in the framework of the EU-founded MammoGrid project. The CADe software is mainly based on wavelet transforms and artificial neural networks. It is able to identify microcalcifications in different datasets of mammograms (i.e. acquired with different machines and settings, digitized with different pitch and bit depth or direct digital ones). The CADe can be remotely run from GRID-connected acquisition and annotation stations, supporting clinicians from geographically distant locations in the interpretation of mammographic data. We report and discuss the system performances on different datasets of mammograms and the status of the GRID-enabled CADe analysis.

physics.med-ph

A scalable Computer-Aided Detection system for microcalcification cluster identification in a pan-European distributed database of mammograms

A computer-aided detection (CADe) system for microcalcification cluster identification in mammograms has been developed in the framework of the EU-founded MammoGrid project. The CADe software is mainly based on wavelet transforms and artificial neural networks. It is able to identify microcalcifications in different kinds of mammograms (i.e. acquired with different machines and settings, digitized with different pitch and bit depth or direct digital ones). The CADe can be remotely run from GRID-connected acquisition and annotation stations, supporting clinicians from geographically distant locations in the interpretation of mammographic data. We report the FROC analyses of the CADe system performances on three different dataset of mammograms, i.e. images of the CALMA INFN-founded database collected in the Italian National screening program, the MIAS database and the so-far collected MammoGrid images. The sensitivity values of 88% at a rate of 2.15 false positive findings per image (FP/im), 88% with 2.18 FP/im and 87% with 5.7 FP/im have been obtained on the CALMA, MIAS and MammoGrid database respectively.

physics.med-ph

Pre-processing methods for nodule detection in lung CT

The use of automatic systems in the analysis of medical images has proven to be very useful to radiologists, especially in the framework of screening programs, in which radiologists make their first diagnosis on the basis of images only, most of those corresponding to healthy patients, and have to distinguish pathological findings from non-pathological ones at an early stage. In particular, we are developing preprocessing methods to be applied for pulmonary nodule Computer Aided Detection in low-dose lung Multi Slice CT (Computed Tomography) images.

physics.med-ph

The INTEGRAL Science Data Centre (ISDC)

The INTEGRAL Science Data Centre (ISDC) provides the INTEGRAL data and means to analyse them to the scientific community. The ISDC runs a gamma ray burst alert system that provides the position of gamma ray bursts on the sky within seconds to the community. It operates a quick-look analysis of the data within few hours that detects new and unexpected sources as well as it monitors the instruments. The ISDC processes the data through a standard analysis the results of which are provided to the observers together with their data.

astro-ph