SearcharxivSearch

arXiv subjects

A. R. Patel

Publications and source records attributed to A. R. Patel.

3 recordsLinked to original sources

Development of a one-dimensional position sensitive detector for Compton X-ray polarimeters

The scientific potential of X-ray polarimetry has long been recognized, but the challenges in measuring polarization have left it largely unexplored, particularly in the hard X-ray regime. While tremendous advancement has been made in soft X-ray polarimetery, the lack of sensitive hard X-ray polarimeters and polarisation measurements continues to limit our understanding of high-energy astrophysical processes. With the development of hard X-ray mirrors, it is now possible to develop a sensitive focal plane hard X-ray polarimeter. One such effort is CXPOL, a prototype developed at PRL, India, which consists of a plastic scintillator as active scatterer readout by PMT surrounded by CsI(Tl) scintillators in cylindrical array with SiPM readout from one side. First results of the prototype have been demonstrated in 20 to 80 keV energy range. The sensitivity of the instrument can be significantly enhanced using faster and better light yield scintillator like NaI as absorbers. Further, the use of a position-sensitive scatterer and absorbers, can also provide spectroscopic information by measuring the interaction position along the length and from the known energy depositions in the detectors. Position sensitive detectors are also helpful in mitigating the systematic effects introduced by the off-axis events in the polarisation measurements. Here, we demonstrate the detection sensitivity in the 100x20x5 mm^3 NaI(Tl) scintillator absorber readout on both ends by SiPM arrays operating in co-incidence. In this work, we characterize the first prototype of this detector system and investigate the variation in energy and position resolution, and light output with irradiation position along the length of the detector. The two end readout in co-incidence also reduces the overall SiPM background per absorber by an order of magnitude, further enhancing the polarimetric sensitivity of the instrument.

astro-ph.IM

Design & development of position sensitive detector for hard X-ray using SiPM and new generation scintillators

There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in the hard X-ray energy range. Here, we present development of a detector module, which consists of 25 mm x 25 mm CeBr3 scintillation detector, read out by a custom designed two dimensional array of Silicon Photo-Multipliers (SiPM). Readout of common cathode of SiPMs provides the spectral measurement whereas the readout of individual SiPM anodes provides measurement of interaction position in the crystal. Preliminary results for spectral and position measurements with the detector module are presented here.

astro-ph.IM

Development of a Hard X-ray focal plane Compton Polarimeter: A compact polarimetric configuration with Scintillators and Si photomultipliers

X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard X-ray polarimetry is more rewarding because the sources are expected to be intrinsically highly polarized at higher energies. With the successful implementation of Hard X-ray optics in NuSTAR, it is now feasible to conceive Compton polarimeters as focal plane detectors. Such a configuration is likely to provide sensitive polarization measurements in hard X-rays with a broad energy band. We are developing a focal plane hard X-ray Compton polarimeter consisting of a plastic scintillator as active scatterer surrounded by a cylindrical array of CsI(Tl) scintillators. The scatterer is 5 mm diameter and 100 mm long plastic scintillator (BC404) viewed by normal PMT. The photons scattered by the plastic scatterer are collected by a cylindrical array of 16 CsI(Tl) scintillators (5 mm x 5 mm x 150 mm) which are read by Si Photomultiplier (SiPM). Use of the new generation SiPMs ensures the compactness of the instrument which is essential for the design of focal plane detectors. The expected sensitivity of such polarimetric configuration and complete characterization of the plastic scatterer, specially at lower energies have been discussed in Chattopadhyay et al. (Exp. Astron. 35, 391-412, 2013; Astrophys. J. Suppl. 212, 12, 2014). In this paper, we characterize the CsI(Tl) absorbers coupled to SiPM. We also present the experimental results from the fully assembled configuration of the Compton polarimeter.

astro-ph.IM