SearcharxivSearch

arXiv subjects

A. Sanuy

Publications and source records attributed to A. Sanuy.

9 recordsLinked to original sources

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Below 100 ps CTR using FastIC+, an ASIC including on-chip digitization for ToF-PET and beyond

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This ASIC, manufactured in 65 nm CMOS technology, can readout positive or negative polarity sensors and provides a digitized measurement of the arrival time and energy of the detected events with a power consumption of 12.5 mW per channel. On-chip digitization is executed by a Time-to-Digital Converter (TDC) based on a Phase-Locked Loop (PLL) generating 16 phases at 1.28 GHz. The internal TDC introduces a jitter contribution of 31.3 ps FWHM, with minimal impact on timing measurements. When evaluating FastIC+ to readout 3$\times$3 mm$^2$ silicon photomultipliers (SiPMs) with a pulsed laser, we achieved a single-photon time resolution (SPTR) of (98 $\pm$ 1) ps FWHM. We also performed time-of-flight positron emission tomography (ToF-PET) experiments using scintillator crystals of different sizes and materials. With LYSO:Ce,Ca crystals of 2.8$\times$2.8$\times$20 mm$^3$ we obtained a coincidence time resolution (CTR) of (130 $\pm$ 1) ps FWHM. With LGSO crystals of 2$\times$2$\times$3 mm$^3$, a CTR of (85 $\pm$ 1) ps FWHM. To the best of our knowledge, this is the first time that a CTR below 100 ps using on-chip digitization is reported.

physics.ins-det

Characterization and performance of an upgraded front-end-board for NectarCAM

This paper presents an analysis of the updated version of the Front-End Board (FEB) for the NectarCAM camera, developed for the Cherenkov Telescope Array Observatory (CTAO). The FEB is a critical component responsible for reading and converting signals from the camera's photo-multiplier tubes into digital data and generating module-level trigger signals. This study provides an overview of the design and performance of the new FEB version, including the use of an improved NECTAr3 chip with advanced features. The NECTAr3 chip contains a switched capacitor array for sampling signals at 1 GHz and a 12-bit analog-to-digital converter (ADC) for digitization upon receiving a trigger signal. The integration of the new NECTAr3 chip results in a significant reduction of NectarCAM's deadtime by an order of magnitude compared to the previous version. The paper also presents the results of laboratory testing, including measurements of timing performance, linearity, dynamic range, and deadtime, to characterize the new FEB's performance.

astro-ph.IM

Squeezing Bose-Bose liquid drops

We explore ultradilute Bose-Bose liquid droplets squeezed by an external harmonic potential in one spatial direction. Our theoretical study is based on a functional that is built using quantum Monte Carlo results of the bulk phase and incorporates finite-range effects. A characteristic feature of these drops is the existence of a critical atom number, that is the minimum number of particles to have a many-body bound state. We report results on the critical atom numbers for different magnetic fields and applying confinement strengths towards a quasi-two-dimensional setup. In the regime where the local density approximation is expected to be valid, we find that the critical atom number decreases linearly with the harmonic oscillator length of the confining potential. With the largest squeezing explored in our work, we predict stable drops at the level of one thousand atoms. Our functional reduces the critical numbers for any confinement and applied magnetic field with respect to the estimations based on the Lee-Huang-Yang model. We observe saturated drops when the number of atoms in the drop is much larger than the critical value, their central density being higher for the quantum Monte Carlo functional than for the Lee-Huang-Yang one.

cond-mat.quant-gas

Performances of an upgraded front-end-board for the NectarCAM camera

The Front-End Board (FEB) is a key component of the NectarCAM camera, which has been developed for the Medium-Sized-Telescopes (MST) of the Cherenkov Telescope Array Observatory (CTAO). The FEB is responsible for reading and converting the signals from the camera's photo-multiplier tubes (PMTs) into digital data, as well as generating module level trigger signals. This contribution provides an overview of the design and performances of a new version of the FEB that utilizes an improved version of the NECTAr chip. The NECTAr chip includes a switched capacitor array for sampling signals at 1 GHz, and a 12-bit analog-to-digital converter (ADC) for digitizing each sample when the trigger signal is received. The integration of this advanced NECTAr chip significantly reduces the deadtime of NectarCAM by an order of magnitude as compared to the previous version. This contribution also presents the results of laboratory testing of the new FEB, including measurements of timing performance, linearity, dynamic range, and deadtime.

astro-ph.IM

Measurement of performance of the NectarCAM photodetectors

NectarCAM is a camera for the medium-sized telescopes of the Cherenkov Telescope Array (CTA), which covers the energy range of 100 GeV to 30 TeV. The camera is equipped with 265 focal plane modules (FPMs). Each FPM comprises 7 pixels, each consisting of a photo-multiplier tube, a preamplifier, an independently controlled power supply, and a common control system. We developed a dedicated test bench to validate and qualify the industrial FPM production and to measure the performance of each FPM in a dark room before its integration in the camera. We report the measured performance of 61 FPM prototypes obtained with our experimental setup. We demonstrate that the gains of the photo multiplier tubes are stable and that pulse widths, transit time spreads, afterpulse rates and charge resolutions are within the specifications for NectarCAM.

astro-ph.IM

NectarCAM : a camera for the medium size telescopes of the Cherenkov Telescope Array

NectarCAM is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a field of view of 8 degrees. Each module includes the photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and Ethernet transceiver. The recorded events last between a few nanoseconds and tens of nanoseconds. The camera trigger will be flexible so as to minimize the read-out dead-time of the NECTAr chips. NectarCAM is designed to sustain a data rate of more than 4 kHz with less than 5\% dead time. The camera concept, the design and tests of the various subcomponents and results of thermal and electrical prototypes are presented. The design includes the mechanical structure, cooling of the electronics, read-out, clock distribution, slow control, data-acquisition, triggering, monitoring and services.

astro-ph.IM

The NectarCAM camera project

In the framework of the next generation of Cherenkov telescopes, the Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium size telescopes covering the central energy range of 100 GeV to 30 TeV. NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view, FoV) in order to image atmospheric Cherenkov showers by measuring the charge deposited within a few nanoseconds time-window. It will have additional features like the capacity to record the full waveform with GHz sampling for every pixel and to measure event times with nanosecond accuracy. An array of a few tens of medium size telescopes, equipped with NectarCAMs, will achieve up to a factor of ten improvement in sensitivity over existing instruments in the energy range of 100 GeV to 10 TeV. The camera is made of roughly 250 independent read-out modules, each composed of seven photo-multipliers, with their associated high voltage base and control, a read-out board and a multi-service backplane board. The read-out boards use NECTAr (New Electronics for the Cherenkov Telescope Array) ASICs which have the dual functionality of analogue memories and Analogue to Digital Converter (ADC). The camera trigger to be used will be flexible so as to minimize the read-out dead-time of the NECTAr chips. We present the camera concept and the design and tests of the various subcomponents. The design includes the mechanical parts, the cooling of the electronics, the readout, the data acquisition, the trigger, the monitoring and services.

astro-ph.IM

Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope

We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.

astro-ph.IM