SearcharxivSearch

arXiv subjects

A. Saputi

Publications and source records attributed to A. Saputi.

At least 19 recordsLinked to original sources

Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter

CRILIN is a high-granularity semi-homogeneous electromagnetic calorimeter based on longitudinally segmented PbF$_2$ crystal matrices read out by UV-extended silicon photomultipliers. The concept combines fast Cherenkov response, fine transverse granularity, longitudinal shower information, and radiation tolerance for future lepton-collider experiments. This paper reports the construction of a large-area prototype and its performance measured in beam tests at the CERN SPS. The detector comprises five $7\times7$ PbF$_2$ crystal matrices, has a depth of about $22X_0$, and is read out by four $3\times3~\mathrm{mm}^2$ SiPMs per crystal integrated in a single electronic channel. Electron data between 10 and 120~GeV and dedicated 150~GeV muon data were used to characterize the detector response. A time resolution below 50~ps is achieved for electron energies above 10~GeV, reaching values below 20~ps above 60~GeV. The energy resolution is described by a stochastic term of $(6.58\pm0.04)\%/\sqrt{E/\mathrm{GeV}}$ and a constant term of $(0.23\pm0.02)\%$, with an additional noise contribution fixed from pedestal data. The longitudinal segmentation enables event-by-event corrections based on the reconstructed shower development, resulting in a significant improvement of the energy resolution. A light yield of approximately 0.54~photoelectrons/MeV is measured consistently using both electron showers and minimum-ionizing particles. A Geant4-based simulation incorporating the relevant experimental effects reproduces the measured energy resolution. These results validate the CRILIN architecture as a compact, fast, and longitudinally segmented electromagnetic calorimeter for future collider experiments.

physics.ins-det

A flexible DAQ system for the Timepix4 ASIC in the 4DPHOTON project

This paper presents the design and implementation of a flexible data acquisition system13 developed for the Timepix4 ASIC within the 4DPHOTON project. The system is based on a modular14 FPGA-centric architecture combining high-speed serial readout, Ethernet-based data transport,15 and deterministic multi-board synchronization. The hardware platform includes a scalable stack16 composed of commercial FPGA carrier boards, FMC-based interface electronics, detector-specific17 chipboards, and a dedicated Trigger Logic Unit for synchronized operation.18 The firmware architecture separates control and data paths, enabling independent configuration19 and high-throughput acquisition through UDP over 10 GbE links. The design supports zero-back-20 pressure operation toward the ASIC and allows adaptation of the readout bandwidth to different21 experimental conditions. Synchronization between multiple DAQ systems is achieved through22 a common clock and trigger distribution network, experimentally demonstrated with sub-100 ps23 precision.24 The system has been developed to support detector characterization, laboratory measurements,25 and beam-test campaigns for the 4DPHOTON detector concept. Hardware organization, firmware26 architecture, synchronization strategy, and performance measurements are presented.

physics.ins-det

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from $4\times 10^{32}\rm{cm}^{-2}\rm{s}^{-1}$ to $2\times 10^{33}\rm{cm}^{-2}\rm{s}^{-1}$. Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90\% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

hep-ex

Radiation tolerance tests on key components of the ePIC-dRICH readout card

The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5x5x12 cm^3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.

physics.ins-det

An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

physics.ins-det

Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider

The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeters should be chosen to reduce the effect of the BIB, while keeping good physics performance. Several requirements can be inferred: i) high granularity to reduce the overlap of BIB particles in the same calorimeter cell; ii) excellent timing (of the order of 100 ps) to reduce the out-of-time component of the BIB; iii) longitudinal segmentation to distinguish the signal showers from the fake showers produced by the BIB; iv) good energy resolution (less than 10%/sqrt(E)) to obtain good physics performance, as has been already demonstrated for conceptual particle flow calorimeters. Our proposal consists of a semi-homogeneous electromagnetic calorimeter based on Lead Fluoride Crystals (PbF2) readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs): the Crilin calorimeter. In this paper, the performances of the Crilin calorimeter in the Muon Collider framework for hadron jets reconstruction have been analyzed. We report the single components characterizations together with the development of a small-scale prototype, consisting of 2 layers of 3x3 crystals each.

physics.ins-det

Commissioning of the PADME experiment with a positron beam

The PADME experiment is designed to search for a hypothetical dark photon $A^{\prime}$ produced in positron-electron annihilation using a bunched positron beam at the Beam Test Facility of the INFN Laboratori Nazionali di Frascati. The expected sensitivity to the $A^{\prime}$-photon mixing parameter $ε$ is 10$^{-3}$, for $A^{\prime}$ mass $\le$ 23.5 MeV/$c^{2}$ after collecting $\sim 10^{13}$ positrons-on-target. This paper presents the PADME detector status after commissioning in July 2019. In addition, the software algorithms employed to reconstruct physics objects, such as photons and charged particles, and the calibration procedures adopted are illustrated in detail. The results show that the experimental apparatus reaches the design performance, and is able to identify and measure standard electromagnetic processes, such as positron Bremsstrahlung, electron-positron annihilation into two photons.

physics.ins-det

Radiation study of Lead Fluoride crystals

Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total fluence. Their loss in transmittance was evaluated at different steps of the photon and neutron irradiation campaign, resulting in a total of 30% loss above 350 nm. With crystals always kept in dark conditions, natural and thermal annealing, as well as optical bleaching with 400 nm light, were performed on the irradiated specimens, resulting in a partial recovery of their original optical characteristics.

physics.ins-det

SHADOWS (Search for Hidden And Dark Objects With the SPS)

We propose a new beam-dump experiment, SHADOWS, to search for a large variety of feebly-interacting particles possibly produced in the interactions of a 400 GeV proton beam with a high-Z material dump. SHADOWS will use the 400 GeV primary proton beam extracted from the CERN SPS currently serving the NA62 experiment in the CERN North area and will take data off-axis when the P42 beam line is operated in beam-dump mode. SHADOWS can accumulate up to a ~2 x10^19 protons on target per year and expand the exploration for a large variety of FIPs well beyond the state-of-the-art in the mass range of MeV-GeV in a parameter space that is allowed by cosmological and astrophysical observations. So far the strongest bounds on the interaction strength of new feebly-interacting light particles with Standard Model particles exist up to the kaon mass; above this threshold the bounds weaken significantly. SHADOWS can do an important step into this still poorly explored territory and has the potential to discover them if they have a mass between the kaon and the beauty mass. If no signal is found, SHADOWS will push the limits on their couplings with SM particles between one and four orders of magnitude in the same mass range, depending on the model and scenario.

hep-ex

Performance of scintillating tiles with direct silicon-photomultiplier (SiPM) readout for application to large area detectors

The light yield, the time resolution and the efficiency of different types of scintillating tiles with direct Silicon Photomultiplier readout and instrumented with a customised front-end electronics have been measured at the Beam Test Facility of Laboratori Nazionali di Frascati and several test stands. The results obtained with different configurations are presented. A time resolution of the order of 300 ps, a light yield of more than 230 photo-electrons, and an efficiency better than 99.8 $\%$ are obtained with $\sim 225$ cm$^2$ large area tiles. This technology is suitable for a wide range of applications in high-energy physics, in particular for large area muon and timing detectors.

physics.ins-det

Long-term Operation of the Multi-Wire-Proportional-Chambers of the LHCb Muon System

The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010 until 2018, we did not observe appreciable signs of ageing of the detector in terms of reduced performance. However, during such a long period, many chamber gas gaps suffered from HV trips. Most of the trips were due to Malter-like effects, characterised by the appearance of local self-sustained high currents, presumably originating from impurities induced during chamber production. Very effective, though long, recovery procedures were implemented with a HV training of the gaps in situ while taking data. The training allowed most of the affected chambers to be returned to their full functionality and the muon detector efficiency to be kept close to 100%. The possibility of making the recovery faster and even more effective by adding a small percentage of oxygen in the gas mixture has been studied and successfully tested.

physics.ins-det

Characterisation and performance of the PADME electromagnetic calorimeter

The PADME experiment at the LNF Beam Test Facility searches for dark photons produced in the annihilation of positrons with the electrons of a fix target. The strategy is to look for the reaction $e^{+}+e^{-}\rightarrow γ+A'$, where $A'$ is the dark photon, which cannot be observed directly or via its decay products. The electromagnetic calorimeter plays a key role in the experiment by measuring the energy and position of the final-state $γ$. The missing four-momentum carried away by the $A'$ can be evaluated from this information and the particle mass inferred. This paper presents the design, construction, and calibration of the PADME's electromagnetic calorimeter. The results achieved in terms of equalisation, detection efficiency and energy resolution during the first phase of the experiment demonstrate the effectiveness of the various tools used to improve the calorimeter performance with respect to earlier prototypes.

physics.ins-det

Mu2e calorimeter readout system

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.

physics.ins-det

Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter

The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process $e^+e^-\rightarrow γA'$, where the $A'$ escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF$_2$ crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/$\sqrt{E}$ with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF$_2$ crystal for higher-energy applications, which has potentially attractive features.

physics.ins-det

The Mu2e calorimeter: quality assurance of production crystals and SiPMs

The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.

physics.ins-det

Design, status and perspective of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.

physics.ins-det

The Mu2e undoped CsI crystal calorimeter

The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

physics.ins-det