SearcharxivSearch

arXiv subjects

A. Sbrizzi

Publications and source records attributed to A. Sbrizzi.

9 recordsLinked to original sources

Fast ungated five-dimensional cardiac MRI on a 1.5 T MR-linac for MRI-guided radiotherapy

Background: Stereotactic arrhythmia radio-ablation (STAR) for patients with ventricular tachycardia is currently limited by complex cardiorespiratory motion. Current 5D-MRI motion models require long acquisition and reconstruction times, limiting clinical viability. Objective: To develop a fast, ungated 5D-MRI reconstruction method for personalized motion characterization to support MRI-guided STAR treatments. Methods: We propose a fast, ungated 5D-MRI reconstruction method based on the CMR-MOTUS framework. The method uses a 3D Cartesian acquisition with a joint optimization framework to reconstruct a motion-corrected reference image and low-rank deformation vector fields (DVFs). By exploiting the low rank structure, we explicitly disentangle respiratory and cardiac motion during optimization. Then, the DVFs are used for 5D-MRI reconstruction with a retrospectively adjustable number of motion states. Validation was performed using digital and physical cardiorespiratory phantoms. Furthermore, the approach was evaluated using 10 healthy volunteers, comparing motion consistency with 2D cine MRI. Results: Validation of 5D CMR-MOTUS using digital and physical phantoms demonstrated accurate 5D-MRI reconstruction. In the physical phantom, 5D CMR-MOTUS achieved a left-ventricle DICE of 0.96 +/- 0.01. In the volunteer cohort, the 5D-MRI scans showed strong motion to 2D cine MRI, with a cardiac motion error of 0.1 +/- 0.9 mm and a respiratory motion error of 0.2 +/- 2.9 mm. Crucially, 5D-MRI data were acquired in 1 minute and reconstructed in 6 minutes. Conclusions: The proposed 5D-MRI method enables rapid, high-quality, and personalized motion characterization, demonstrating potential for integration into MRI-guided STAR treatments. Data Availability: The 3D k-space data and 5D reconstructions for the ten volunteers are publicly available at https://doi.org/10.5281/zenodo.21278894

physics.med-ph

Molecular effects in low-energy muon transfer from muonic hydrogen to oxygen

In the present study we determine from the available experimental data the cross section of muon transfer to molecular oxygen at low energies with account of the oxygen molecule structure. Building on an earlier work, the results highlight the role of the molecular structure effects and signifcantly improve the agreement with theoretical calculations of the muon transfer rate. An effcient computational model of the kinetics of processes involving muonic hydrogen atoms in gaseous mixture of H2 and O2 is developed and analyzed. The model is applied in the description of the FAMU experiment for the measurement of the hyperfine splitting in muonic hydrogen and the Zemach radius of the proton.

physics.atom-ph

First operation of the FAMU experiment at the RIKEN-RAL high intensity muon beam facility

The FAMU experiment, supported and funded by the Italian Institute of Nuclear Physics (INFN) and by the Science and Technology Facilities Council (STFC), aims to perform the first measurement of the ground-state hyperfine splitting (1S-hfs) of muonic hydrogen ($\mu H$). This quantity is highly sensitive to the proton's Zemach radius $R_Z$. An experimental determination of $R_Z$ provides significant constraints on the parametrization of the proton form factors as well as on theoretical models describing the proton's electromagnetic structure. Following years of technological and methodological development, the FAMU experiment began operations in 2023 at Port 1 of the RIKEN-RAL muon beam line at the ISIS Neutron and Muon Source facility (Didcot, UK). In this paper, we first describe the unique detection technique employed by FAMU to determine the 1S-hfs of muonic hydrogen, followed by a detailed presentation of the final experimental layout. Finally, we report the first outcome from the 2023 commissioning run and from the initial physics runs performed in 2023 and 2024.

physics.atom-ph

Data-driven discovery of mechanical models directly from MRI spectral data

Finding interpretable biomechanical models can provide insight into the functionality of organs with regard to physiology and disease. However, identifying broadly applicable dynamical models for in vivo tissue remains challenging. In this proof of concept study we propose a reconstruction framework for data-driven discovery of dynamical models from experimentally obtained undersampled MRI spectral data. The method makes use of the previously developed spectro-dynamic framework which allows for reconstruction of displacement fields at high spatial and temporal resolution required for model identification. The proposed framework combines this method with data-driven discovery of interpretable models using Sparse Identification of Non-linear Dynamics (SINDy). The design of the reconstruction algorithm is such that a symbiotic relation between the reconstruction of the displacement fields and the model identification is created. Our method does not rely on periodicity of the motion. It is successfully validated using spectral data of a dynamic phantom gathered on a clinical MRI scanner. The dynamic phantom is programmed to perform motion adhering to 5 different (non-linear) ordinary differential equations. The proposed framework performed better than a 2-step approach where the displacement fields were first reconstructed from the undersampled data without any information on the model, followed by data-driven discovery of the model using the reconstructed displacement fields. This study serves as a first step in the direction of data-driven discovery of in vivo models.

physics.med-ph

The muon beam monitor for the FAMU experiment: design, simulation, test and operation

FAMU is an INFN-led muonic atom physics experiment based at the RIKEN-RAL muon facility at the ISIS Neutron and Muon Source (United Kingdom). The aim of FAMU is to measure the hyperfine splitting in muonic hydrogen to determine the value of the proton Zemach radius with accuracy better than 1%.The experiment has a scintillating-fibre hodoscope for beam monitoring and data normalisation. In order to carry out muon flux estimation, low-rate measurements were performed to extract the single-muon average deposited charge. Then, detector simulation in Geant4 and FLUKA allowed a thorough understanding of the single-muon response function, crucial for determining the muon flux. This work presents the design features of the FAMU beam monitor, along with the simulation and absolute calibration measurements in order to enable flux determination and enable data normalisation.

physics.ins-det

Investigating the Proton Structure: The FAMU experiment

The article gives the motivations for the measurement of the hyperfine splitting (hfs) in the ground state of muonic hydrogen to explore the properties of the proton at low momentum transfer. It summarizes these proposed measurement methods and finally describes the FAMU experiment in more detail.

physics.atom-ph

Status of the detector setup for the FAMU experiment at RIKEN-RAL for a precision measurement of the Zemach radius of the proton in muonic hydrogen

The FAMU experiment at RIKEN-RAL is a muonic atom experiment with the aim to determine the Zemach radius of the proton by measuring the 1s hyperfine splitting in muonic hydrogen. The activity of the FAMU Collaboration in the years 2015-2023 enabled the final optimisation of the detector-target setup as well as the gas working condition in terms of temperature, pressure and gas mixture composition. The experiment has started its data taking in July 2023. The status of the detector setup for the 2023 experimental runs, for the beam characterisation and muonic X-ray detection in the 100-200 keV energy range, is presented and discussed.

physics.atom-ph

Experimental determination of the energy dependence of the rate of the muon transfer reaction from muonic hydrogen to oxygen for collision energies up to 0.1 eV

We report the first experimental determination of the collision-energy dependence of the muon transfer rate from the ground state of muonic hydrogen to oxygen at near-thermal energies. A sharp increase by nearly an order of magnitude in the energy range 0 - 70 meV was found that is not observed in other gases. The results set a reliable reference for quantum-mechanical calculations of low-energy processes with exotic atoms, and provide firm ground for the measurement of the hyperfine splitting in muonic hydrogen and the determination of the Zemach radius of the proton by the FAMU collaboration.

physics.atom-ph

Measurement of the muon transfer rate from muonic hydrogen to oxygen in the range 70-336 K

The first measurement of the temperature dependence of the muon transfer rate from muonic hydrogen to oxygen was performed by the FAMU collaboration in 2016. The results provide evidence that the transfer rate rises with the temperature in the range 104-300 K. This paper presents the results of the experiment done in 2018 to extend the measurements towards lower (70 K) and higher (336 K) temperatures. The 2018 results confirm the temperature dependence of the muon transfer rate observed in 2016 and sets firm ground for comparison with the theoretical predictions.

physics.atom-ph