SearcharxivSearch

arXiv subjects

A. Seiden

Publications and source records attributed to A. Seiden.

At least 19 recordsLinked to original sources

Characterization of the first full-size production for ePIC TOF layers

Low-Gain Avalanche Detectors (LGADs) are characterized by a fast rise time (500 ps) and extremely good time resolution (down to 17 ps). The intrinsic low granularity of LGADs and the large power consumption of readout chips for precise timing are problematic in near-future experiments such as e+e- Higgs factories (FCC-ee) and the ePIC detector at the Electron-Ion Collider. AC-coupled LGADs, where the readout metal is AC-coupled through an insulating oxide layer, could solve both issues at the same time thanks to the 100% fill factor and charge-sharing capabilities. Charge sharing between electrodes allows a hit position resolution well below the pitch/$\sqrt12$ of standard segmented detectors. At the same time, it relaxes the channel density and power consumption requirements of readout chips. Extensive laboratory characterization of AC-LGAD devices from the first full-size (up to 3x4 cm) production from HPK for ePIC will be shown in this contribution. Both pixel and strip geometry was produced and tested. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R&D program at the EIC.

physics.ins-det

Synchrotron light source focused X-ray detection with LGADs, AC-LGADs and TI-LGADs

The response of Low Gain Avalanche Diodes (LGADs), a type of thin silicon detector with internal gain, to X-rays of energies between 6-16~keV was characterized at the Stanford Synchrotron Radiation Lightsource (SSRL). The utilized beamline at SSRL was 7-2, with a nominal beam size of 30~$\mu$m, repetition rate of 500~MHz, and with an energy dispersion $\Delta E/E$ of $10^{-4}$. Multi-channel LGADs, AC-LGADs, and TI-LGADs of different thicknesses and gain layer configurations from Hamamatsu Photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested. The sensors were read out with a discrete component board and digitized with a fast oscilloscope or a CAEN fast digitizer. The devices' energy response, energy resolution, and time resolution were measured as a function of X-ray energy and position. The charge collection and multiplication mechanism were simulated using TCAD Sentaurus, and the results were compared with the collected data.

physics.ins-det

European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment

PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/\mu}$ to 1 part in $10^4$, improving the current experimental result $R_{e/\mu}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/\mu}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.

hep-ex

Performance of neutron and proton irradiated AC-LGAD sensors

Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13~$n_{eq}/cm^2$ fluence over the lifetime of the experiment.

physics.ins-det

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50~$\mu$m, 100~$\mu$m, 150~$\mu$m were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR) and energy linearity is an important property for particle ID capabilities.

physics.ins-det

Gain suppression study on LGADs at the CENPA tandem accelerator

Low-Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. One recent challenge in the use of LGADs, studied by several research groups, is the gain suppression mechanism for large localized charge deposits. Using the CENPA Tandem accelerator at the University of Washington, the response of the LGADs to MeV-range energy deposits from a proton beam was studied. Two LGAD prototypes and a PIN diode were characterized, and the gain of the devices was determined as a function of bias voltage, incidence beam angle and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. %At the center of the experiment, a high-granularity active target (ATAR) will stop the pion and characterize its decay. A range of deposited charge from Minimum Ionizing Particle (MIP, few 10s of KeV) from positrons to several MeV from the stopping pions/muons is expected in PIONEER; the detection and separation of close-by hits in such a wide dynamic range will be a main challenge of the experiment. To achieve this goal, the gain suppression mechanism has to be understood fully.

physics.ins-det

First test beam measurement of the 4D resolution of an RSD 450 microns pitch pixel matrix connected to a FAST2 ASIC

This paper reports on the spatial and temporal resolutions of an RSD 450 microns pitch pixels array measured at the DESY test beam facility. RSDs, Resistive Silicon Detectors, also known as AC-LGAD, achieve excellent position and temporal resolution by exploiting charge sharing among neighboring electrodes. The RSD matrix used in this study is part of the second FBK RSD production, RSD2, and it is composed of 450 microns pitch pixel with cross-shaped electrodes. A 7-pixel matrix was read out by the FAST2 ASIC, a 16-channel amplifier fully custom ASIC developed by INFN Torino using the 110 nm CMOS technology. The total area covered by the matrix is about 1.5 mm$^2$. The position resolution reached in this test is 15 microns, about 4\% of the pitch. The temporal resolution achieved in this work is 60 ps, dominated by the FAST2 resolution. The work also demonstrates that RSD sensors with cross-shaped electrodes achieve 100% fill factor and homogenous resolutions over the whole matrix surface, making them a suitable choice for 4D tracking applications.

physics.ins-det

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

The response of Low Gain Avalanche Diodes (LGADs), which are a type of thin silicon detector with internal gain, to X-rays of energies between 6-70 keV was characterized at the SLAC light source (SSRL). The utilized beamline at SSRL was 11-2, with a nominal beam size of 3 cm x 0.5 cm, a repetition rate of 500 MHz, and very monochromatic. LGADs of different thicknesses and gain layer configurations were read out using fast amplification boards and digitized with a fast oscilloscope. Standard PiN devices were characterized as well. The devices' energy resolution and time resolution as a function of X-ray energy were measured. The charge collection and multiplication mechanism were simulated using TCAD Sentaurus, and the results were compared with the collected data.

physics.ins-det

TCAD simulation of AC-LGADs

Low Gain Avalanche Detectors (LGADs) are thin silicon detectors with moderate internal signal amplification and time resolution as good as 17 ps for minimum ionizing particles. However, the current major limiting factor in granularity is due to protection structures preventing breakdown caused by high electric fields at the edge of the segmented implants. This structure, called Junction Termination Extension (JTE), causes a region of 50-100~\um\ of inactive space. Therefore, the granularity of LGAD sensors is currently limited to the mm scale. A solution would be AC-coupled LGADs (AC-LGADs) which can provide spatial resolution on the 10's of um scale. This is achieved by an un-segmented (p-type) gain layer and (n-type) N-layer, and a dielectric layer separating the metal readout pads. The high spatial precision is achieved by using the information from multiple pads, exploiting the intrinsic charge-sharing capabilities of the AC-LGAD provided by the common N-layer. TCAD software (Silvaco and Sentaurus) was used to simulate the behavior of AC-LGADs. A set of simulated devices was prepared by changing several parameters in the sensor: N+ resistivity, strip length, and bulk thickness.

physics.ins-det

First Test Results of the Trans-Impedance Amplifier Stage of the Ultra-fast HPSoC ASIC

We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 um thick AC-LGAD. The evaluation of the analog front end with \b{eta}-particles impinging on 3x3 AC-LGAD arrays (500 um pitch, 200x200 um2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.

physics.ins-det

High-Precision 4D Tracking with Large Pixels using Thin Resistive Silicon Detectors

The basic principle of operation of silicon sensors with resistive read-out is built-in charge sharing. Resistive Silicon Detectors (RSD, also known as AC-LGAD), exploiting the signals seen on the electrodes surrounding the impact point, achieve excellent space and time resolutions even with very large pixels. In this paper, a TCT system using a 1064 nm picosecond laser is used to characterize sensors from the second RSD production at the Fondazione Bruno Kessler. The paper first introduces the parametrization of the errors in the determination of the position and time coordinates in RSD, then outlines the reconstruction method, and finally presents the results. Three different pixel sizes are used in the analysis: 200 x 340, 450 x 450, and 1300 x 1300 microns^2. At gain = 30, the 450 x 450 microns^2 pixel achieves a time jitter of 20 ps and a spatial resolution of 15 microns concurrently, while the 1300 x 1300 microns^2 pixel achieves 30 ps and 30 micron, respectively. The implementation of cross-shaped electrodes improves considerably the response uniformity over the pixel surface.

physics.ins-det

Inter-pad dead regions of irradiated FBK Low Gain Avalanche Detectors

Low Gain Avalanche Detectors (LGADs) are a type of thin silicon detector with a highly doped gain layer. LGADs manufactured by Fondazione Bruno Kessler (FBK) were tested before and after irradiation with neutrons. In this study, the Inter-pad distances (IPDs), defined as the width of the distances between pads, were measured with a TCT laser system. The response of the laser was tuned using $β$-particles from a 90Sr source. These insensitive "dead zones" are created by a protection structure to avoid breakdown, the Junction Termination Extension (JTE), which separates the pads. The effect of neutron radiation damage at \fluence{1.5}{15}, and \fluence{2.5}{15} on IPDs was studied. These distances are compared to the nominal distances given from the vendor, it was found that the higher fluence corresponds to a better matching of the nominal IPD.

physics.ins-det

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

physics.ins-det

Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment

The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.

hep-ex

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

hep-ex

Tuning of gain layer doping concentration and Carbon implantation effect on deep gain layer

Next generation Low Gain Avalanche Diodes (LGAD) produced by Hamamatsu photonics (HPK) and Fondazione Bruno Kessler (FBK) were tested before and after irradiation with ~1MeV neutrons at the JSI facility in Ljubljana. Sensors were irradiated to a maximum 1-MeV equivalent fluence of 2.5E15 Neq/cm2. The sensors analysed in this paper are an improvement after the lessons learned from previous FBK and HPK productions that were already reported in precedent papers. The gain layer of HPK sensors was fine-tuned to optimize the performance before and after irradiation. FBK sensors instead combined the benefit of Carbon infusion and deep gain layer to further the radiation hardness of the sensors and reduced the bulk thickness to enhance the timing resolution. The sensor performance was measured in charge collection studies using \b{eta}-particles from a 90Sr source and in capacitance-voltage scans (C-V) to determine the bias to deplete the gain layer. The collected charge and the timing resolution were measured as a function of bias voltage at -30C. Finally a correlation is shown between the bias voltage to deplete the gain layer and the bias voltage needed to reach a certain amount of gain in the sensor. HPK sensors showed a better performance before irradiation while maintaining the radiation hardness of the previous production. FBK sensors showed exceptional radiation hardness allowing a collected charge up to 10 fC and a time resolution of 40 ps at the maximum fluence.

physics.ins-det

Potential for Improved Time Resolution Using Very Thin Ultra-Fast Silicon Detectors (UFSDs)

Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain allows excellent time measurement for impinging minimum ionizing charged particles. An important design consideration is the sensor thickness, which has a strong impact on the achievable time resolution. We present the result of measurements for LGADs of thickness between 20 micro-m and 50 micro-m. The data are fit to a formula that captures the impact of both electronic jitter and Landau fluctuations on the time resolution. The data illustrate the importance of having a saturated electron drift velocity and a large signal-to-noise in order to achieve good time resolution. Sensors of 20 micro-m thickness offer the potential of 10 to 15 ps time resolution per measurement, a significant improvement over the value for the 50 micro-m sensors that have been typically used to date.

physics.ins-det

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution's feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 micro-m thick LGADs at -30 degree celsius with a precision of 14.3 ps (uncertainty 1.5 ps).

physics.ins-det