SearcharxivSearch

arXiv subjects

A. Snoch

Publications and source records attributed to A. Snoch.

9 recordsLinked to original sources

Femtoscopy Measurement with S$\pi$RIT TPC in Radioactive BeamHeavy-ion Collisions

Femtoscopy is a powerful tool for exploring the dynamic emitting structure in heavy-ion collisions, while radioactive beam heavy-ion collisions enable the investigation of nuclear matter under extreme isospin conditions. Here, we successfully perform femtoscopy measurements using the S$\pi$RIT Time Projection Chamber (TPC). A dedicated correction scheme for track merging and splitting is proposed, which is well applicable to rectangular TPCs housed inside dipole magnets and effectively improves the reconstructed correlation functions at small relative momenta. Focusing on the proton-proton (p-p) correlation function in the 270 MeV/u $^{132}\text{Sn}+^{124}\text{Sn}$ system, we successfully apply the track merging and splitting correction; additionally, the TPC angular acceptance exhibits a negligible impact on the correlation function. A systematic uncertainty quantification framework is established. The experimental results of the p-p correlation function confirm the feasibility of the S$\pi$RIT TPC for femtoscopy measurements and provide technical support for high-precision femtoscopy studies using rectangular TPCs in radioactive beam heavy-ion collisions.

physics.ins-det

Large amplification of the isospin-dependence of proton emitting source size in radioactive heavy-ion collisions: a signal of n-p correlation

We report proton-proton correlation function measurements in central $^{132}$Sn+$^{124}$Sn and $^{108}$Sn+$^{112}$Sn collisions at 270 MeV/nucleon. The proton emitting source sizes are extracted for the systems by using femtoscopic imaging technique. The fast dynamic core radius for the neutron-rich system is found to be $2.22 \pm 0.13\ \text{(stat.)} \pm 0.07\ \text{(syst.)}$ fm, which is approximately 24\% larger than that for the neutron-deficient system, $1.74 \pm 0.08\ \text{(stat.)} \pm 0.05\ \text{(syst.)}$ fm. This difference is an order of magnitude larger than the $\sim$3\% difference in the ground-state charge radii of the projectile nuclei. Transport model simulations based on mean-field dynamics cannot reproduce this amplification. The observation reveals a beyond-mean-field mechanism associated to short-range neutron-proton correlations, which dynamically enhance the proton emitting source in the neutron-rich environment. Our results demonstrate that heavy-ion collisions induced by radioactive beam, combined with femtoscopic precision, provide a new hadronic probe of short-range correlation, and that careful treatment of the beyond-mean-field interactions are required in modeling such processes.

nucl-ex

The LHCb VELO Upgrade Module Construction

The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{\mu m}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.

physics.ins-det

Constraining nucleon effective masses with flow and stopping observables from the S$\pi$RIT experiment

Properties of the nuclear equation of state (EoS) can be probed by measuring the dynamical properties of nucleus-nucleus collisions. In this study, we present the directed flow ($v_1$), elliptic flow ($v_2$) and stopping (VarXZ) measured in fixed target Sn + Sn collisions at 270 AMeV with the S$\pi$RIT Time Projection Chamber. We perform Bayesian analyses in which EoS parameters are varied simultaneously within the Improved Quantum Molecular Dynamics-Skyrme (ImQMD-Sky) transport code to obtain a multivariate correlated constraint. The varied parameters include symmetry energy, $S_0$, and slope of the symmetry energy, $L$, at saturation density, isoscalar effective mass, $m_{s}^*/m_{N}$, isovector effective mass, $m_{v}^{*}/m_{N}$ and the in-medium cross-section enhancement factor $\eta$. We find that the flow and VarXZ observables are sensitive to the splitting of proton and neutron effective masses and the in-medium cross-section. Comparisons of ImQMD-Sky predictions to the S$\pi$RIT data suggest a narrow range of preferred values for $m_{s}^*/m_{N}$, $m_{v}^{*}/m_{N}$ and $\eta$.

nucl-ex

Isoscaling in central Sn+Sn collisions at 270 MeV/u

Experimental information on fragment emissions is important in understanding the dynamics of nuclear collisions and in the development of transport model simulating heavy-ion collisions. The composition of complex fragments emitted in the heavy-ion collisions can be explained by statistical models, which assume that thermal equilibrium is achieved at collision energies below 100 MeV/u. Our new experimental data together with theoretical analyses for light particles from Sn+Sn collisions at 270 MeV/u, suggest that the hypothesis of thermal equilibrium breaks down for particles emitted with high transfer momentum. To inspect the system's properties in such limit, the scaling features of the yield ratios of particles from two systems, a neutron-rich system of ${}^{132}\mathrm{Sn}+{}^{124}\mathrm{Sn}$ and a nearly symmetric system of ${}^{108}\mathrm{Sn}+{}^{112}\mathrm{Sn}$, are examined in the framework of the statistical multifragmentation model and the antisymmetrized molecular dynamics model. The isoscaling from low energy particles agree with both models. However the observed breakdown of isoscaling for particles with high transverse momentum cannot be explained by the antisymmetrized molecular dynamics model.

nucl-ex

Probing the Symmetry Energy with the Spectral Pion Ratio

Many neutron star (NS) properties, such as the proton fraction within a NS, reflect the symmetry energy contributions to the Equation of State that dominate when neutron and proton densities differ strongly. To constrain these contributions at supra-saturation densities, we measure the spectra of charged pions produced by colliding rare isotope tin (Sn) beams with isotopically enriched Sn targets. Using ratios of the charged pion spectra measured at high transverse momenta, we deduce the slope of the symmetry energy to be $42 < L < 117$ MeV. This value is slightly lower but consistent with the $L$ values deduced from a recent measurement of the neutron skin thickness of $^{208}$Pb.

nucl-ex

Symmetry energy investigation with pion production from Sn+Sn systems

In the past two decades, pions created in the high density regions of heavy ion collisions have been predicted to be sensitive at high densities to the symmetry energy term in the nuclear equation of state, a property that is key to our understanding of neutron stars. In a new experiment designed to study the symmetry energy, the multiplicities of negatively and positively charged pions have been measured with high accuracy for central $^{132}$Sn+$^{124}$Sn, $^{112}$Sn+$^{124}$Sn, and $^{108}$Sn+$^{112}$Sn collisions at $E/A=270~\mathrm{MeV}$ with the S$π$RIT Time Projection Chamber. While the uncertainties of individual pion multiplicities are measured to 4\%, those of the charged pion multiplicity ratios are measured to 2\%. We compare these data to predictions from seven major transport models. The calculations reproduce qualitatively the dependence of the multiplicities and their ratios on the total neutron to proton number in the colliding systems. However, the predictions of the transport models from different codes differ too much to allow extraction of reliable constraints on the symmetry energy from the data. This finding may explain previous contradictory conclusions on symmetry energy constraints obtained from pion data in Au+Au system. These new results call for better understanding of the differences among transport codes, and new observables that are more sensitive to the density dependence of the symmetry energy.

nucl-ex

The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform

The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector technologies. The Vertex Locator (VELO) surrounding the interaction region is used to reconstruct the collision points (primary vertices) and decay vertices of long-lived particles (secondary vertices). The upgraded VELO will be composed of 52 modules placed along the beam axis divided into two retractable halves. The modules will each be equipped with 4 silicon hybrid pixel tiles, each read out by 3 VeloPix ASICs. The total output data rate anticipated for the whole detector will be around 1.6 Tbit/s. The highest occupancy ASICs will have pixel hit rates of approximately 900 Mhit/s, with the corresponding output data rate of 15 Gbit/s. The LHCb upgrade detector will be the first detector to read out at the full LHC rate of 40 MHz. The VELO upgrade will utilize the latest detector technologies to read out at this rate while maintaining the required radiation-hard profile and minimizing the detector material.

physics.ins-det

KATANA - a charge-sensitive triggering system for the S$π$RIT experiment

KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has been built and used as a trigger and veto detector for the S$π$RIT TPC at RIKEN. Its construction allows operating in magnetic field and providing fast response for ionizing particles, giving the approximate forward multiplicity and charge information. Depending on this information, trigger and veto signals are generated. The article presents performance of the detector and details of its construction. A simple phenomenological parametrization of the number of emitted scintillation photons in plastic scintillator is proposed. The effect of the light output deterioration in the plastic scintillator due to the in-beam irradiation is discussed.

physics.ins-det