A prototype of a large tunable Fabry-Perot interferometer for solar spectroscopy

Large Fabry-Perot Interferometers are used in a variety of astronomical instrumentation, including spectro-polarimeters for 4-meter class solar telescopes. In this work we comprehensively characterize the cavity of a prototype 150 mm Fabry-Perot interferometer, sporting a novel, fully symmetric design. Of note, we define a new method to properly assess the gravity effects on the interferometer's cavity when the system is used in either the vertical or horizontal configuration, both typical of solar observations. We show that the symmetric design very effectively limits the combined effects of pre-load and gravity forces to only a few nm over a 120 mm diameter illuminated surface, with gravity contributing about 2 nm peak-to-valley (0.3 nm rms) in either configuration. We confirm a variation of the tilt between the plates of the interferometer during the spectral scan, which can be mitigated with appropriate corrections to the spacing commands. Finally, we show that the dynamical response of the new system fully satisfies typical operational scenarios. We conclude that large, fully symmetric Fabry-Perot interferometers can be safely used within solar instrumentation in both, horizontal and vertical position, with the latter better suited to limiting the overall volume occupied by such an instrument.

astro-ph.IM

New technique to measure the cavity defects of Fabry-Perot interferometers

(Abridged): We define and test a new technique to accurately measure the cavity defects of air-spaced FPIs, including distortions due to the spectral tuning process typical of astronomical observations. We further develop a correction technique to maintain the shape of the cavity as constant as possible during the spectral scan. These are necessary steps to optimize the spectral transmission profile of a two-dimensional spectrograph using one or more FPIs. We devise a generalization of the techniques developed for the so-called phase-shifting interferometry to the case of FPIs. The technique is applicable to any FPI that can be tuned via changing the cavity spacing ($z$-axis), and can be used for any etalon regardless of the coating' reflectivity. The major strength of our method is the ability to fully characterize the cavity during a spectral scan, allowing for the determination of scan-dependent modifications of the plates. As a test, we have applied this technique to three 50 mm diameter interferometers, with cavity gaps ranging between 600 micron and 3 mm, coated for use in the visible range. We obtain accurate and reliable measures of the cavity defects of air-spaced FPIs, and of their evolution during the entire spectral scan. Our main, and unexpected, result is that the relative tilt between the two FPI plates varies significantly during the spectral scan, and can dominate the cavity defects; in particular, we observe that the tilt component at the extremes of the scan is sensibly larger than at the center of the scan. Exploiting the capability of the electronic controllers to set the reference plane at any given spectral step, we develop a correction technique that allows the minimization of the tilt during a complete spectral scan. The correction remains highly stable over long periods, well beyond the typical duration of astronomical observations.

astro-ph.SR

Modification of the structure of diamond with MeV ion implantation

We present experimental results and numerical simulations to investigate the modification of structural-mechanical properties of ion-implanted single-crystal diamond. A phenomenological model is used to derive an analytical expression for the variation of mass density and elastic properties as a function of damage density in the crystal. These relations are applied together with SRIM Monte Carlo simulations to set up Finite Element simulations for the determination of internal strains and surface deformation of MeV-ion-implanted diamond samples. The results are validated through comparison with high resolution X-ray diffraction and white-light interferometric profilometry experiments. The former are carried out on 180 keV B implanted diamond samples, to determine the induced structural variation, in terms of lattice spacing and disorder, whilst the latter are performed on 1.8 MeV He implanted diamond samples to measure surface swelling. The effect of thermal processing on the evolution of the structural-mechanical properties of damaged diamond is also evaluated by performing the same profilometric measurements after annealing at 1000 °C, and modeling the obtained trends with a suitably modified analytical model. The results allow the development of a coherent model describing the effects of MeV-ion-induced damage on the structural-mechanical properties of single-crystal diamond. In particular, we suggest a more reliable method to determine the so-called diamond "graphitization threshold" for the considered implantation type.

cond-mat.mtrl-sci

Micro and nano-patterning of single-crystal diamond by swift heavy ion irradiation

This paper presents experimental data and analysis of the structural damage caused by swift-heavy ion irradiation of single-crystal diamond. The patterned buried structural damage is shown to generate, via swelling, a mirror-pattern on the sample surface, which remains largely damage-free. While extensive results are available for light ion implantations, this effect is reported here for the first time in the heavy ion regime, where a completely different range of input parameters (in terms of ion species, energy, stopping power, etc.) is available for customized irradiation. The chosen ion species are Au and Br, in the energy range 10-40 MeV. The observed patterns, as characterized by profilometry and atomic force microscopy, are reported in a series of model experiments, which show swelling patterns ranging from a few nm to above 200 nm. Moreover, a systematic phenomenological modelling is presented, in which surface swelling measurements are correlated to buried crystal damage. A comparison is made with data for light ion implantations, showing good compatibility with the proposed models. The modelling presented in this work can be useful for the design and realization of micropatterned surfaces in single crystal diamond, allowing to generate highly customized structures by combining appropriately chosen irradiation parameters and masks.

cond-mat.mtrl-sci

Micro-beam and pulsed laser beam techniques for the micro-fabrication of diamond surface and bulk structures

Micro-fabrication in diamond is involved in a wide set of emerging technologies, exploiting the exceptional characteristics of diamond for application in bio-physics, photonics, radiation detection. Micro ion-beam irradiation and pulsed laser irradiation are complementary techniques, which permit the implementation of complex geometries, by modification and functionalization of surface and/or bulk material, modifying the optical, electrical and mechanical characteristics of the material. In this article we summarize the work done in Florence (Italy) concerning ion beam and pulsed laser beam micro-fabrication in diamond.

cond-mat.mtrl-sci

Complex refractive index variation in proton-damaged diamond

An accurate control of the optical properties of single crystal diamond during microfabrication processes such as ion implantation plays a crucial role in the engineering of integrated photonic devices. In this work we present a systematic study of the variation of both real and imaginary parts of the refractive index of single crystal diamond, when damaged with 2 and 3 MeV protons at low-medium fluences (range: 10^15 - 10^17 cm^-2). After implanting in 125x125 um^2 areas with a scanning ion microbeam, the variation of optical pathlength of the implanted regions was measured with laser interferometric microscopy, while their optical transmission was studied using a spectrometric set-up with micrometric spatial resolution. On the basis of a model taking into account the strongly non-uniform damage profile in the bulk sample, the variation of the complex refractive index as a function of damage density was evaluated.

cond-mat.mtrl-sci