SearcharxivSearch

arXiv subjects

A. Soter

Publications and source records attributed to A. Soter.

15 recordsLinked to original sources

Energy, time, and position resolution measurements of an array of large tapered LYSO crystals

We report on the performance of six custom-made tapered LYSO crystals of unprecedented volume, which constitute a sector of the 19 radiation length electromagnetic calorimeter planned for the PIONEER experiment. The longitudinal response uniformity of each crystal was measured using radioactive sources before characterizing the energy and time resolution of the crystals in an array using a 20 to 80 MeV positron beam at the Paul Scherrer Institute. The array demonstrated an energy resolution better than 2 % for energies above 40 MeV and a time resolution better than 130 ps for energies above 30 MeV. The spatial resolution was measured in the central region of the array to be 4.9 mm at 70 MeV, and was extrapolated to 5.4 mm across a 30 mm radius region using Geant4 simulation. The measured properties satisfy the key design parameters of the PIONEER calorimeter for the measurement of rare pion decays.

physics.ins-det

European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment

PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/μ}$ to 1 part in $10^4$, improving the current experimental result $R_{e/μ}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/μ}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.

hep-ex

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each $2.5\times 2.5 \times 18$ cm$^3$ crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30 - 100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. As an example of the results, the energy resolution at 70 MeV of 1.52 $\pm$ 0.03% is more than two times better than reported results using previous generation LYSO crystals.

physics.ins-det

Orders of Magnitude Improved Cyclotron-Mode Cooling for Non-Destructive Spin Quantum Transition Spectroscopy with Single Trapped Antiprotons

We demonstrate efficient sub-thermal cooling of the modified cyclotron mode of a single trapped antiproton and reach particle temperatures $T_+=E_+/k_\text{B}$ below $200\,$mK in preparation times shorter than $500\,$s. This corresponds to the fastest resistive single-particle cyclotron cooling to sub-thermal temperatures ever demonstrated. By cooling trapped particles to such low energies, we demonstrate the detection of antiproton spin transitions with an error-rate $<0.000025$, more than three orders of magnitude better than in previous best experiments. This method will have enormous impact on multi-Penning-trap experiments that measure magnetic moments with single nuclear spins for tests of matter/antimatter symmetry, high-precision mass-spectrometry, and measurements of electron $g$-factors bound to highly-charged ions that test quantum electrodynamics.

physics.atom-ph

Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature

We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.

physics.atom-ph

Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $μ$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $μ$p atom diffusion in the hydrogen gas and the arrival time of the $μ$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $μ$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.

physics.atom-ph

BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies

Currently, the only worldwide source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of the fundamental interactions and their symmetries. However, the magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of CPT invariance with antiprotons, and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and the detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.

physics.ins-det

Testing CPT Invariance by High-Precision Comparisons of Fundamental Properties of Protons and Antiprotons at BASE

The BASE collaboration at the Antiproton Decelerator facility of CERN compares the fundamental properties of protons and antiprotons using advanced Penning-trap systems. In previous measurement campaigns, we measured the magnetic moments of the proton and the antiproton, reaching (sub-)parts-in-a-billion fractional uncertainty. In the latest campaign, we have compared the proton and antiproton charge-to-mass ratios with a fractional uncertainty of 16 parts in a trillion. In this contribution, we give an overview of the measurement campaign, and detail how its results are used to constrain nine spin-independent coefficients of the Standard-Model Extension in the proton and electron sector.

hep-ex

Room-temperature emission of muonium from aerogel and zeolite targets

A low-emittance, high-intensity atomic beam of muonium ($\mathrm{M}=μ^+ + \mathrm{e}^-$) using superfluid helium as muon-to-muonium converter is being developed at the Paul Scherrer Institute (PSI). This beam could advance laser spectroscopy of muonium and allow the first atomic interferometry experiments for the direct observation of the M gravitational interaction. In this paper, we describe the development of compact detection schemes which resulted in the background-suppressed observation of atomic muonium in vacuum, and can be adapted for cryogenic measurements. Using these setups, we compared the emission characteristics of various muonium production targets using low momentum ($p_μ = 11$-$13~$MeV/c) muons, and observed muonium emission from zeolite targets into vacuum for the first time. For a specific laser-ablated aerogel target, we determined a muon-to-vacuum-muonium conversion efficiency of $7.23 \pm 0.05 \text{(stat)} ^{+1.06}_{-0.76}\text{(sys)}\,\text{%}$, assuming thermal emission of muonium. Moreover, we investigated muonium-helium collisions and from it we determined an upper temperature limit of 0.3 K for the superfluid helium converter.

physics.atom-ph

Laser excitation of the 1s-hyperfine transition in muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($μ$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $μ$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine state, {then} is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after the collisional deexcitation is used as a signature of a successful laser transition between hyperfine states. In this paper, we calculate the combined probability that a $μ$p atom initially in the singlet hyperfine state undergoes a laser excitation to the triplet state followed by a collisional-induced deexcitation back to the singlet state. This combined probability has been computed using the optical Bloch equations including the inelastic and elastic collisions. Omitting the decoherence effects caused by {the laser bandwidth and }collisions would overestimate the transition probability by more than a factor of two in the experimental conditions. Moreover, we also account for Doppler effects and provide the matrix element, the saturation fluence, the elastic and inelastic collision rates for the singlet and triplet states, and the resonance linewidth. This calculation thus quantifies one of the key unknowns of the HFS experiment, leading to a precise definition of the requirements for the laser system and to an optimization of the hydrogen gas target where $μ$p is formed and the laser spectroscopy will occur.

physics.atom-ph

Scintillation detectors with silicon photomultiplier readout in a dilution refrigerator at temperatures down to 0.2 K

We are developing a novel high-brightness atomic beam, comprised of a two-body exotic atom called muonium (M $ = μ^+ + e^-$), for next-generation atomic physics and gravitational interaction measurements. This M source originates from a thin sheet of superfluid helium (SFHe), hence diagnostics and later measurements require a detection system which is operational in a dilution cryostat at temperatures below 1 K. In this paper, we describe the operation and characterization of silicon photomultipliers (SiPMs) at ultra-low temperatures in SFHe targets. We show the temperature dependence of the signal shape, breakdown voltage, and single photon detection efficiency, concluding that single photon detection with SiPMs below 0.85 K is feasible. Furthermore, we show the development of segmented scintillation detectors, where 16 channels at 1.7 K and one channel at 170 mK were commissioned using a muon beam.

physics.ins-det

Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment

The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/μ}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $π^+\to π^0 e^+ ν(γ)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.

hep-ex

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/μ}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/μ}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $π^+\to π^0 e^+ ν(γ)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$π$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

hep-ex

Science Case for the new High-Intensity Muon Beams HIMB at PSI

In April 2021, scientists active in muon physics met to discuss and work out the physics case for the new High-Intensity Muon Beams (HIMB) project at PSI that could deliver of order $10^{10}$\,s$^{-1}$ surface muons to experiments. Ideas and concrete proposals were further substantiated over the following months and assembled in the present document. The high intensities will allow for completely new experiments with considerable discovery potential and unique sensitivities. The physics case is outstanding and extremely rich, ranging from fundamental particle physics via chemistry to condensed matter research and applications in energy research and elemental analysis. In all these fields, HIMB will ensure that the facilities S$μ$S and CHRISP on PSI's High Intensity Proton Accelerator complex HIPA remain world-leading, despite the competition of muon facilities elsewhere.

hep-ex

Collision Induced Relaxations within the Antiprotonic Helium Hyperfine Structure

We report the first measurements of the inelastic spin exchange collision rate between the Hyperfine (HF) levels of antiprotonic helium. We measure the time dependent evolution of the (37, 35) substates to obtain an inelastic collision rate which qualitatively agrees with recent theoretical calculations. We evaluate these results by using the obtained rate as a parameter in a rigorous simulation which we then compare to to previously measured data. We find that our measurement slightly underestimates the collision rate and therefore conclude that the actual value most probably falls within the upper, rather than lower, limit of the error.

physics.atom-ph