SearcharxivSearch

arXiv subjects

A. Sugiyama

Publications and source records attributed to A. Sugiyama.

15 recordsLinked to original sources

Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures

Argon with an admixture of CF4 is expected to be a good candidate for the gas mixture to be used for a time projection chamber (TPC) in the future linear collider experiment because of its small transverse diffusion of drift electrons especially under a strong magnetic field. In order to confirm the superiority of this gas mixture over conventional TPC gases we carried out cosmic ray tests using a GEM-based TPC operated mostly in Ar-CF4-isobutane mixtures under 0 - 1 T axial magnetic fields. The measured gas properties such as gas gain and transverse diffusion constant as well as the observed spatial resolution are presented.

physics.ins-det

A novel technique for the measurement of the avalanche fluctuations of a GEM stack using a gating foil

We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment (ILD-TPC). In addition to the gating function, the gating foil is capable of controlling the average fraction of drift electrons detected after gas amplification. The signal charge width and shape (skewness) for electron-ion pairs created by a pulsed UV laser as a function of the transmission rate of the gating foil can be used to determine the relative variance of gas gain for single electrons. We present the measurement principle and the result obtained using a stack of gas electron multipliers (GEMs) operated in a gas mixture of Ar-CF$_4$(3%)-isobutane(2%) at atmospheric pressure. Also discussed is the influence of the avalanche fluctuations on the spatial resolution of the ILD-TPC.

physics.ins-det

Measurement of the electron transmission rate of the gating foil for the TPC of the ILC experiment

We have developed a gating foil for the time projection chamber envisaged as a central tracker for the international linear collider experiment. It has a structure similar to the Gas Electron Multiplier (GEM) with a higher optical aperture ratio and functions as an ion gate without gas amplification. The transmission rate for electrons was measured in a counting mode for a wide range of the voltages applied across the foil using an $^{55}$Fe source and a laser in the absence of a magnetic field. The blocking power of the foil against positive ions was estimated from the electron transmissions.

physics.ins-det

Readout technologies for directional WIMP Dark Matter detection

The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.

physics.ins-det

Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures: II

The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite projected angles with respect to the pad-row normal. The degradation of the resolution due to the angular pad effect was confirmed to be consistent with the prediction of a simple calculation taking into account the cluster-size distribution and the avalanche fluctuation.

physics.ins-det

Activity report of ILD-TPC Asia group

The purpose of ILD-TPC Asia group is realization of high precision Time Projection Chamber (TPC) with Gas Electron Multiplier (GEM) as a central tracker in International Linear Collider (ILC). We have been studying the many R&D items to build the real detector as a member of LCTPC collaboration. This paper describes the our efforts for realization of the ILD-TPC, the result of test beam using large prototype TPC, local field distortion, positive ion effects and gate devices, and cooling electronics which are key items to build ILD-TPC.

physics.ins-det

Study of the K0(L) --> pi0 pi0 nu nu-bar decay

The rare decay K0(L) --> pi0 pi0 nu nu-bar was studied with the E391a detector at the KEK 12-GeV proton synchrotron. Based on 9.4 x 10^9 K0L decays, an upper limit of 8.1 x 10^{-7} was obtained for the branching fraction at 90% confidence level. We also set a limit on the K0(L) --> pi0 pi0 X (X --> invisible particles) process; the limit on the branching fraction varied from 7.0 x 10^{-7} to 4.0 x 10^{-5} for the mass of X ranging from 50 MeV/c^2 to 200 MeV/c^2.

hep-ex

Search for the decay $K_L^0 \rightarrow 3γ$

We performed a search for the decay $K_L^0 \rightarrow 3γ$ with the E391a detector at KEK. In the data accumulated in 2005, no event was observed in the signal region. Based on the assumption of $K_L^0 \rightarrow 3γ$ proceeding via parity-violation, we obtained the single event sensitivity to be $(3.23\pm0.14)\times10^{-8}$, and set an upper limit on the branching ratio to be $7.4\times10^{-8}$ at the 90% confidence level. This is a factor of 3.2 improvement compared to the previous results. The results of $K_L^0 \rightarrow 3γ$ proceeding via parity-conservation were also presented in this paper.

hep-ex

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

astro-ph.CO

Cosmic Ray Tests of the Prototype TPC for the ILC Experiment

A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments under a magnetic field up to 4 T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC readout could not be a fall-back option of the ILC-TPC under a strong axial magnetic field of 4 T since its spatial resolution suffered severely from the so called E x B effect in the vicinity of the wire planes. The GEM readout, on the other hand, was found to be virtually free from the E x B effect as had been expected and gave the resolution determined by the transverse diffusion of the drift electrons (diffusion limited). Furthermore, GEMs allow a wider choice of gas mixtures than MWPCs. Among the gases we tried so far a mixture of Ar-CF4-isobutane, in which MWPCs could be prone to discharges, seems promising as the operating gas of the ILC-TPC because of its small diffusion constant especially under a strong magnetic field. We report the measured drift properties of this mixture including the diffusion constant as a function of the electric field and compare them with the predictions of Magboltz. Also presented is the spatial resolution of a GEM-based ILC-TPC estimated from the measurement with the prototype.

physics.ins-det

Search for a light pseudoscalar particle in the decay $K^0_L \to π^0 π^0 X$

We performed a search for a light pseudoscalar particle $X$ in the decay $K_L^0->pi0pi0X$, $X->γγ$ with the E391a detector at KEK. Such a particle with a mass of 214.3 MeV/$c^2$ was suggested by the HyperCP experiment. We found no evidence for $X$ and set an upper limit on the product branching ratio for $K_L^0->pi0pi0X$, $X->γγ$ of $2.4 \times 10^{-7}$ at the 90% confidence level. Upper limits on the branching ratios in the mass region of $X$ from 194.3 to 219.3 MeV/$c^2$ are also presented.

hep-ex

A GEM TPC End-Panel Pre-Prototype

A GEM TPC end panel pre-prototype was constructed for a large LC-TPC prototype to test its basic design philosophy and some of its engineering details. Its interim test results are presented.

physics.ins-det

Measurements of |Vub| at Belle

We have tried to measure $|V_{ub}|$ using inclusive semileptonic decay measurements with three different methods. The full reconstruction tag is the one of the most feasible method to measure inclusive process. Semileptonic $B\to D^{(*)}\ellν$ tag is another method to separate signal and tag $B$ mesons. New kinematic variable is used to enhance double semileptonic decays of both $B$ meson. We also improve the neutrino reconstruction technique solving a combination of decay products into signal and tag $B$ mesons using the simulated annealing method.

hep-ex

Examination of T/CP Invariance in the e+e- --> tau+ tau- Reaction

We propose a method to examine the T/CP invariance of the heaviest lepton, tau, by means of a triple-momentum correlation for the reaction e^+e^- -->tau^+tau^-, tau --> e/mu nu nubar during the course of the B-Factory experimental program. An unprecedented high sensitivity could be obtained without requiring a high integrated luminosity.

hep-ex