SearcharxivSearch

arXiv subjects

A. Sukhanov

Publications and source records attributed to A. Sukhanov.

At least 19 recordsLinked to original sources

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

physics.acc-ph

Cold Test Results of Pre-Production PIP-II SSR2 Cavities with High-Power Couplers in the Fermilab Spoke Test Cryostat

As part of the PIP-II project at Fermilab, a pre-production cryomodule featuring 325 MHz Single Spoke Resonator type 2 (SSR2) superconducting RF cavities is under construction. These SSR2 cavities are fabricated by industry partners and undergo initial cold testing at our collaborating institution, IJCLab in France, utilizing low-power coupler. Subsequently, the cavities are subjected to final qualification at Fermilab, complete with tuner and high-power coupler assemblies. This paper provides an overview of the ongoing efforts dedicated to high-power testing of jacketed SSR2 cavities in the Spoke Test Cryostat (STC) at Fermilab. Performance parameters obtained from these tests are presented, offering valuable insights into the cavities operational characteristics and readiness for integration into the PIP-II cryomodule.

physics.acc-ph

Performance of PIP-II High-beta 650 Cryomodule After Transatlantic Shipping

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

physics.acc-ph

Results of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and discuss the possible contribution of HOMs to heat loads and beam dynamics.

physics.acc-ph

Impact of Solenoid Induced Residual Magnetic Fields on The Prototype SSR1 CM Performance

A prototype cryomodule containing eight Single Spoke Resonators type-1 (SSR1) operating at 325 MHz and four superconducting focusing lenses was successfully assembled, cold tested, and accelerated beam in the framework of the PIP-II project at Fermilab. The impact of induced residual magnetic fields from the solenoids on performance of cavities is presented in this contribution. In addition, design optimizations for the production cryomodules as a result of this impact are highlighted.

physics.acc-ph

Optically Pumped Polarized $^3$He$^{++}$ Ion Source Development for RHIC/EIC

The proposed polarized $^3$He$^{++}$ acceleration in RHIC and the future Electron-Ion Collider will require about $2\times10^{11}$ ions in the source pulse. A new technique had been proposed for production of high intensity polarized $^3$He$^{++}$ ion beams. It is based on ionization and accumulation of the $^3$He gas (polarized by metastability-exchange optical pumping and in the 5 T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel $^3$He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized $^3$He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3--5 T field has been developed. The $^3$He polarization 80--85\% (and sufficiently long $\sim30$ min relaxation time) was obtained in the \lq\lq{open}\rq\rq\ cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and $^3$He $^4$He absolute nuclear polarimeter at 6 MeV $^3$He$^{++}$ beam energy is also presented.

physics.ins-det

Validation of the 650 MHZ SRF tuner on the low and high beta cavities for PIP-II at 2 K*

The PIP-II linac will include thirty-six beta=0.61 and twenty-four beta=0.92 650 MHz 5 cell elliptical SRF cavities. Each cavity will be equipped with a tuning system consisting of a double lever slow tuner for coarse frequency tuning and a piezoelectric actuator for fine frequency tuning. The same tuner will be used for both the beta=0.61 and beta=0.92 cavities. Results of testing the cavity-tuner system for the beta=0.61 will be presented for the first time.

physics.acc-ph

Design of a medium energy, high average power superconducting e-beam accelerator for environmental applications

We present the technical and engineering design of a medium energy (10 MeV) and high average power (1 MW) electron beam accelerator intended for irradiation treatment of high volume industrial and municipal wastewater. The accelerator uses superconducting radiofrequency (SRF) cavity technology for producing the high average beam power with $>$90% RF to beam efficiency. The design of the accelerator is simplified and tailored for industrial settings by adopting the cryocooler conduction-cooling technique for the SRF cavity instead of a conventional liquid helium bath cryo-system. The technical design is supplemented with a detailed analysis of capital and operating cost of the accelerator. The designed accelerator can treat up to 12 million gallons per day of wastewater, requires capital of $\sim\$$8M for construction, and has $\sim$13.5 cents/ton/kGy in material processing cost.

physics.acc-ph

Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes

The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.

physics.ins-det

Participant and spectator scaling of spectator fragments in Au+Au and Cu+Cu collisions at sqrt(sNN) = 19.6 and 22.4 GeV

Spectator fragments resulting from relativistic heavy ion collisions, consisting of single protons and neutrons along with groups of stable nuclear fragments up to Nitrogen (Z=7), are measured in PHOBOS. These fragments are observed in Au+Au (sqrt(sNN)=19.6 GeV) and Cu+Cu (22.4 GeV) collisions at high pseudorapidity ($η$). The dominant multiply-charged fragment is the tightly bound Helium ($α$), with Lithium, Beryllium, and Boron all clearly seen as a function of collision centrality and pseudorapidity. We observe that in Cu+Cu collisions, it becomes much more favorable for the $α$ fragments to be released than Lithium. The yields of fragments approximately scale with the number of spectator nucleons, independent of the colliding ion. The shapes of the pseudorapidity distributions of fragments indicate that the average deflection of the fragments away from the beam direction increases for more central collisions. A detailed comparison of the shapes for $α$ and Lithium fragments indicates that the centrality dependence of the deflections favors a scaling with the number of participants in the collision.

nucl-ex

Nucleon-Gold Collisions at 200 AGeV Using Tagged d+Au Interactions in PHOBOS

Forward calorimetry in the PHOBOS detector has been used to study charged hadron production in d+Au, p+Au and n+Au collisions at sqrt(s_nn) = 200 GeV. The forward proton calorimeter detectors are described and a procedure for determining collision centrality with these detectors is detailed. The deposition of energy by deuteron spectator nucleons in the forward calorimeters is used to identify p+Au and n+Au collisions in the data. A weighted combination of the yield of p+Au and n+Au is constructed to build a reference for Au+Au collisions that better matches the isospin composition of the gold nucleus. The p_T and centrality dependence of the yield of this improved reference system is found to match that of d+Au. The shape of the charged particle transverse momentum distribution is observed to extrapolate smoothly from pbar+p to central d+Au as a function of the charged particle pseudorapidity density. The asymmetry of positively- and negatively-charged hadron production in p+Au is compared to that of n+Au. No significant asymmetry is observed at mid-rapidity. These studies augment recent results from experiments at the LHC and RHIC facilities to give a more complete description of particle production in p+A and d+A collisions, essential for the understanding the medium produced in high energy nucleus-nucleus collisions.

nucl-ex

CDF Run II Silicon Vertex Detector Annealing Study

Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron collider delivered 12~fb$^{-1}$ of $p\bar{p}$ collisions at $\sqrt{s}=1.96$ TeV to the Collider Detector at Fermilab (CDF). During that time, the CDF silicon vertex detector was subject to radiation doses of up to 12 Mrad. After the end of operations, the silicon detector was annealed for 24 days at $18^{\circ}$C. In this paper, we present a measurement of the change in the bias currents for a subset of sensors during the annealing period. We also introduce a novel method for monitoring the depletion voltage throughout the annealing period. The observed bias current evolution can be characterized by a falling exponential term with time constant $τ_I=17.88\pm0.36$(stat.)$\pm0.25$(syst.) days. We observe an average decrease of $(27\pm3)\%$ in the depletion voltage, whose evolution can similarly be described by an exponential time constant of $τ_V=6.21\pm0.21$ days. These results are consistent with the Hamburg model within the measurement uncertainties.

physics.ins-det

Operational experience, improvements, and performance of the CDF Run II silicon vertex detector

The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated luminosity of p-pbar collisions at sqrt(s)=1.96 TeV. Many physics analyses undertaken by CDF require heavy flavor tagging with large charged particle tracking acceptance. To realize these goals, in 2001 CDF installed eight layers of silicon microstrip detectors around its interaction region. These detectors were designed for 2--5 years of operation, radiation doses up to 2 Mrad (0.02 Gy), and were expected to be replaced in 2004. The sensors were not replaced, and the Tevatron run was extended for several years beyond its design, exposing the sensors and electronics to much higher radiation doses than anticipated. In this paper we describe the operational challenges encountered over the past 10 years of running the CDF silicon detectors, the preventive measures undertaken, and the improvements made along the way to ensure their optimal performance for collecting high quality physics data. In addition, we describe the quantities and methods used to monitor radiation damage in the sensors for optimal performance and summarize the detector performance quantities important to CDF's physics program, including vertex resolution, heavy flavor tagging, and silicon vertex trigger performance.

physics.ins-det

High Gradient Tests of the Fermilab SSR1 Cavity

In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed very well during cold test in Vertical Test Station at FNAL. One dressed cavity was also tested successfully in Horizontal Test Station. Currently we are building 8 cavity cryomodule for PIXIE project. Additional 10 cavities were manufactured in the industry and on-going cold test results will be presented in this poster.

physics.acc-ph

A Proposal for the Muon Piston Calorimeter Extension (MPC-EX) to the PHENIX Experiment at RHIC

The PHENIX MPC-EX detector is a Si-W preshower extension to the existing PHENIX Muon Piston Calorimeters (MPC). The MPC-EX will consist of eight layers of alternating W absorber and Si mini-pad sensors and will be installed in time for RHIC Run-15. Covering a large pseudorapidity range, 3.1 < eta < 3.8, the MPC-EX and MPC access high-x partons in the projectile nucleon (and low-x partons in the target nucleon) in p+A and transversely polarized proton-proton collisions at 200 GeV. With the addition of the MPC-EX, the neutral pion reconstruction range extends to energies > 80 GeV, a factor of four improvement over current capabilities. Not only will the MPC-EX strengthen PHENIX's existing forward neutral pion and jet measurements, it also provides the necessary neutral pion rejection to make a prompt photon measurement feasible in both p+A and p+p collisions. With this neutral pion rejection, prompt (direct + fragmentation) photon yields at high p_T, p_T > 3 GeV, can be statistically extracted using a double ratio method. In p+A collisions direct photons at forward rapidities are optimally sensitive to the gluon distribution because, unlike pions, direct photons are only produced by processes that are directly sensitive to the gluon distribution at leading order. A measurement of the forward prompt photon R_pA will cleanly access and greatly expand our understanding of the gluon nuclear parton distribution functions and provide important information about the initial state in heavy ion collisions. In transversely polarized p+p collisions the MPC-EX will make possible a measurement of the prompt photon single spin asymmetry A_N, and will help elucidate the correlation of valence partons in the proton with the proton spin.

nucl-ex

Stability Regions Around the Components of the Triple System 2001 SN263

The NEAs (Near-Earth Asteroids) are good targets for spatial missions, since they periodically approach the orbit of the Earth. Recently, the NEA (153591) 2001 SN263 was chosen as the target of the ASTER MISSION- First Brazilian Deep Space Mission, planned to be launched in 2015. In February 2008, the radio astronomers from Arecibo-Puerto Rico concluded that (153591) 2001 SN263 is actually a triple system (Nolan et al., 2008). The announcement of the ASTER MISSION has motivated the development of the present work, whose goal is to characterize regions of stability and instability of the triple system (153591) 2001 SN263. The method adopted consisted in dividing the region around the system into four distinct regions. We have performed numerical integrations of systems composed by seven bodies: Sun, Earth, Mars, Jupiter and the three components of the system, and by thousands of particles randomly distributed within the demarcated regions, for the planar and inclined prograde cases. The results are diagrams of semi-major axis versus eccentricity, where it is shown the percentage of particles that survive for each set of initial conditions. The regions where 100% of the particles survive is defined as stable regions. We found that the stable regions are in the neighborhood of Alpha and Beta, and in the external region. It was identified resonant motion of the particles with Beta and Gamma in the internal regions, which lead to instability. For particles with I>45° in the internal region, where I is the inclination with respect to Alpha's equator, there is no stable region, except for the particles placed really close to Alpha. The stability in the external region is not affected by the variation of inclination. We also present a discussion on the long-term stability in the internal region, for the planar and circular cases, with comparisons with the short-term stability.

astro-ph.EP

Phobos results on charged particle multiplicity and pseudorapidity distributions in Au+Au, Cu+Cu, d+Au, and p+p collisions at ultra-relativistic energies

Pseudorapidity distributions of charged particles emitted in $Au+Au$, $Cu+Cu$, $d+Au$, and $p+p$ collisions over a wide energy range have been measured using the PHOBOS detector at RHIC. The centrality dependence of both the charged particle distributions and the multiplicity at midrapidity were measured. Pseudorapidity distributions of charged particles emitted with $|η|<5.4$, which account for between 95% and 99% of the total charged-particle emission associated with collision participants, are presented for different collision centralities. Both the midrapidity density, $dN_{ch}/dη$, and the total charged-particle multiplicity, $N_{ch}$, are found to factorize into a product of independent functions of collision energy, $\sqrt{s_{_{NN}}}$, and centrality given in terms of the number of nucleons participating in the collision, $N_{part}$. The total charged particle multiplicity, observed in these experiments and those at lower energies, assumes a linear dependence of $(\ln s_{_{NN}})^2$ over the full range of collision energy of $\sqrt{s_{_{NN}}}$=2.7-200 GeV.

nucl-ex

Scaling properties in bulk and p$_{\rm T}$-dependent particle production near midrapidity in relativistic heavy ion collisions

The centrality dependence of the midrapidity charged-particle multiplicity density ($|η|$$<$1) is presented for Au+Au and Cu+Cu collisions at RHIC over a broad range of collision energies. The multiplicity measured in the Cu+Cu system is found to be similar to that measured in the Au+Au system, for an equivalent N$_{\rm part}$, with the observed factorization in energy and centrality still persistent in the smaller Cu+Cu system. The extent of the similarities observed for bulk particle production is tested by a comparative analysis of the inclusive transverse momentum distributions for Au+Au and Cu+Cu collisions near midrapidity. It is found that, within the uncertainties of the data, the ratio of yields between the various energies for both Au+Au and Cu+Cu systems are similar and constant with centrality, both in the bulk yields as well as a function of p$_{\rm T}$, up to at least 4 GeV/$c$. The effects of multiple nucleon collisions that strongly increase with centrality and energy appear to only play a minor role in bulk and intermediate transverse momentum particle production.

nucl-ex