Searcharxiv⌕ Search

arXiv subjects

A. T. Fienberg

Publications and source records attributed to A. T. Fienberg.

59 records · Page 4Linked to original sources

The Status and Prospects of the Muon $g-2$ Experiment at Fermilab

The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_μ$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at Brookhaven National Lab. There stands a greater than 3 standard deviations discrepancy between the Brookhaven measurement of $a_μ$ and the theoretical value predicted using the Standard Model. The Fermilab experiment seeks to either resolve or confirm this discrepancy, which is suggestive of new physics interactions. To achieve the E989 target precision, the anomalous precession frequency of muons in a magnetic storage ring must be determined with a systematic uncertainty below 70\,ppb, and the average magnetic field experienced by these stored muons must be known equally well. The muon anomalous precession frequency is imprinted on the time-dependent energy distribution of decay positrons observed by 24 electromagnetic calorimeters. A suite of pulsed NMR probes continually monitors the magnetic field. This document presents the current status of the Fermilab experiment while emphasizing the ongoing analysis of the 2018 Run 1 dataset and the systematic effects that complicate it.

hep-ex↗

Design and performance of SiPM-based readout of PbF2 crystals for high-rate, precision timing applications

We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. The performance is documented in a series of bench and beam tests.

physics.ins-det↗

Electron beam test of key elements of the laser-based calibration system for the muon $g$ $-$ $2$ experiment

We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

physics.ins-det↗

Test of candidate light distributors for the muon (g$-$2) laser calibration system

The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.

physics.ins-det↗

Studies of an array of PbF2 Cherenkov crystals with large-area SiPM readout

The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 -- 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes versus energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 1e-4 per hour. After accounting for longitudinal fluctuation losses, those crystals wrapped in a white, diffusive wrapping exhibited an energy resolution sigma/E of (3.4 +- 0.1) % per sqrt(E/GeV), while those wrapped in a black, absorptive wrapping had (4.6 +- 0.3) % per sqrt(E/GeV). The white-wrapped crystals---having nearly twice the total light collection---display a generally wider and impact-position-dependent pulse shape owing to the dynamics of the light propagation, in comparison to the black-wrapped crystals, which have a narrower pulse shape that is insensitive to impact position.

physics.ins-det↗