SearcharxivSearch

arXiv subjects

A. Tan

Publications and source records attributed to A. Tan.

15 recordsLinked to original sources

Data reduction pipeline for the SuMAC millimeter-wave spectrometer at the LMT

We present the data reduction and analysis pipeline for the SuperSpec-MUSCAT Collaboration (SuMAC) along with several key science data products. In Summer 2025, SuperSpec on-chip spectrometers operating from $190-300$ GHz at $R\sim200$ were deployed in the MUSCAT cryostat at the Large Millimeter Telescope, obtaining several days of on-sky data. Analysis of these data has been used to characterize noise performance and study spectra of various astrophysical sources, establishing the viability of deploying SuperSpec detectors in future instruments. These proceedings discuss the modular data reduction pipeline which uses timestreams of the kinetic inductance detectors (KIDs) and auxiliary instrument data to generate a variety of data products. We present an on-sky calibration method for converting the KID fractional frequency shift to on-sky brightness temperature. The mapmaking module generates 3D data cubes of extended sources, while the spectrum module produces a millimeter-wave spectrum of an object. The observations all incorporate measurements of the atmosphere to model and correct for absorption. We also discuss data processing choices including detector weighting, despiking, and notch filtering. Finally, we present preliminary data products including detection of carbon monoxide in NGC 253 and spectral maps of the central region of the Orion KL nebula.

astro-ph.IM

Towards Low-Energy Electron High-Resolution Spectroscopy with Transition-Edge Sensors

We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a critical temperature of $\sim$ 80 mK. The electron source is based on vertically-aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the (92 - 99) eV kinetic energy range, we obtain a Gaussian energy resolution for fully-absorbed electrons of (0.479 $\pm$ 0.041 $\pm$ 0.055) eV. When considering the full-width at half-maximum of the peak, the corresponding resolution is of (1.44 $\pm$ 0.17 $\pm$ 0.27) eV. The former represents an improvement of (46 - 60)% with respect to previous results, and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 20, and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.

physics.ins-det

Ultra-high precision high voltage system for PTOLEMY

The PTOLEMY project is prototyping a novel electromagnetic filter for high-precision $\beta$ spectroscopy, with the ultimate and ambitious long-term goal of detecting the cosmic neutrino background through electron capture on tritium bound to graphene. Intermediate small-scale prototypes can achieve competitive sensitivity to the effective neutrino mass, even with reduced energy resolution. To reach an energy resolution better than \SI{500}{meV} at the tritium $\beta$-spectrum endpoint of \SI{18.6}{keV}, and accounting for all uncertainties in the filtering chain, the electrode voltage must be controlled at the level of a few parts per million and monitored in real time. In this work, we present the first results obtained in this effort, using a chain of commercial ultra-high-precision voltage references, read out by precision multimeters and a \emph{field mill} device. The currently available precision on high voltage is, in the conservative case, as low as \SI{0.2}{ppm} per \SI{1}{kV} single board and $\lesssim$ \SI{50}{mV} over the \SI{10}{kV} series, presently limited by field mill read-out noise. However, assuming uncorrelated Gaussian noise extrapolation, the real precision could in principle be as low as \SI{0.05}{ppm} over \SI{20}{kV}.

physics.ins-det

A Demonstration of Slowed Electron ${\bf E} \times {\bf B}$ Drift for PTOLEMY

To resolve the effective neutrino mass $m_\beta$ with an energy resolution of 50~meV, the PTOLEMY experiment has proposed a novel transverse electromagnetic filtering process. Substantially reducing the kinetic energy of tritium $\beta$-decay electrons by counteracting motion from ${\bf E}$ $\times$ ${\bf B}$ and $\nabla{\rm B}$ drift, the PTOLEMY filter requires an input of emitted electron kinematic information to generate a tailored, suitable electric field for each candidate. The collaboration proposes to extract these quantities by using antennae to observe the relativistic frequency shift of emitted cyclotron radiation as an electron transits by ${\bf E}$ $\times$ ${\bf B}$ drift through a uniform magnetic field region preceding the filter. Electrons must be contained within this region long enough such that an adequate integrated radiated power signal is received to accurately estimate these kinematics. This necessitates a controlled, slowed drift speed. This paper presents the experimental design to vary ${\bf E}$ $\times$ ${\bf B}$ drift speed of carbon-14 $\beta$-decay electrons using a custom electrode field cage situated between the pole faces of an electromagnet. Matching our results with high-fidelity simulation, we deduce a capacity to increase particle time of flight by a factor of 5 in the field cage's slow drift region. Limited only by the dimensions of our system, we assert drift speed can be arbitrarily slowed to meet the needs of PTOLEMY's future detector. Actualizing such a system is a crucial milestone in developing the detector, enabling future cyclotron radiation measurements, filter implementation, and source injection.

physics.ins-det

Energetic electron precipitation driven by electromagnetic ion cyclotron waves from ELFIN's low altitude perspective

We review comprehensive observations of electromagnetic ion cyclotron (EMIC) wave-driven energetic electron precipitation using data from the energetic electron detector on the Electron Losses and Fields InvestigatioN (ELFIN) mission, two polar-orbiting low-altitude spinning CubeSats, measuring 50-5000 keV electrons with good pitch-angle and energy resolution. EMIC wave-driven precipitation exhibits a distinct signature in energy-spectrograms of the precipitating-to-trapped flux ratio: peaks at 0.5 MeV which are abrupt (bursty) with significant substructure (occasionally down to sub-second timescale). Multiple ELFIN passes over the same MLT sector allow us to study the spatial and temporal evolution of the EMIC wave - electron interaction region. Using two years of ELFIN data, we assemble a statistical database of 50 events of strong EMIC wave-driven precipitation. Most reside at L=5-7 at dusk, while a smaller subset exists at L=8-12 at post-midnight. The energies of the peak-precipitation ratio and of the half-peak precipitation ratio (our proxy for the minimum resonance energy) exhibit an L-shell dependence in good agreement with theoretical estimates based on prior statistical observations of EMIC wave power spectra. The precipitation ratio's spectral shape for the most intense events has an exponential falloff away from the peak (i.e., on either side of 1.45 MeV). It too agrees well with quasi-linear diffusion theory based on prior statistics of wave spectra. Sub-MeV electron precipitation observed concurrently with strong EMIC wave-driven 1MeV precipitation has a spectral shape that is consistent with efficient pitch-angle scattering down to 200-300 keV by much less intense higher frequency EMIC waves. These results confirm the critical role of EMIC waves in driving relativistic electron losses. Nonlinear effects may abound and require further investigation.

physics.space-ph

Microscopic theory of thermalization in 1D with nonlinear bath coupling

Using a non-perturbative classical model, we numerically investigate the dynamics of mobile particles interacting with an infinite chain of harmonic oscillators, an abstraction of ionic conduction through solid-state materials. We show that coupling between the mobile particles and a single mass of the chain is sufficient to induce dissipation of the mobile particles' energy over a wide range of system parameters. When we introduce thermal fluctuations in the position of the chain mass, the mobile particles exhibit thermalization, eventually reaching the same temperature scale as the chain. This model demonstrates how a minimal set of ingredients can exhibit a link between microscopic motion and macroscopic observables, with computationally efficient simulations. Finally, we suggest some experimental platforms that could realize such a model.

cond-mat.mes-hall

Heisenberg's uncertainty principle in the PTOLEMY project: a theory update

We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $\beta$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.

hep-ph

Implementation and Optimization of the PTOLEMY Transverse Drift Electromagnetic Filter

The PTOLEMY transverse drift filter is a new concept to enable precision analysis of the energy spectrum of electrons near the tritium beta-decay endpoint. This paper details the implementation and optimization methods for successful operation of the filter. We present the first demonstrator that produces the required magnetic field properties with an iron return-flux magnet. Two methods for the setting of filter electrode voltages are detailed. The challenges of low-energy electron transport in cases of low field are discussed, such as the growth of the cyclotron radius with decreasing magnetic field, which puts a ceiling on filter performance relative to fixed filter dimensions. Additionally, low pitch angle trajectories are dominated by motion parallel to the magnetic field lines and introduce non-adiabatic conditions and curvature drift. To minimize these effects and maximize electron acceptance into the filter, we present a three-potential-well design to simultaneously drain the parallel and transverse kinetic energies throughout the length of the filter. These optimizations are shown, in simulation, to achieve low-energy electron transport from a 1 T iron core (or 3 T superconducting) starting field with initial kinetic energy of 18.6 keV drained to <10 eV (<1 eV) in about 80 cm. This result for low field operation paves the way for the first demonstrator of the PTOLEMY spectrometer for measurement of electrons near the tritium endpoint to be constructed at the Gran Sasso National Laboratary (LNGS) in Italy.

physics.ins-det

Correlation Driven Transient Hole Dynamics Resolved in Space and Time in the Isopropanol Molecule

The possibility of suddenly ionized molecules undergoing extremely fast electron hole dynamics prior to significant structural change was first recognized more than 20 years ago and termed charge migration. The accurate probing of ultrafast electron hole dynamics requires measurements that have both sufficient temporal resolution and can detect the localization of a specific hole within the molecule. We report an investigation of the dynamics of inner valence hole states in isopropanol where we use an x-ray pump/x-ray probe experiment, with site and state-specific probing of a transient hole state localized near the oxygen atom in the molecule, together with an ab initio theoretical treatment. We record the signature of transient hole dynamics and make the first observation of dynamics driven by frustrated Auger-Meitner transitions. We verify that the hole lifetime is consistent with our theoretical prediction. This state-specific measurement paves the way to widespread application for observations of transient hole dynamics localized in space and time in molecules and thus to charge transfer phenomena that are fundamental in chemical and material physics.

physics.chem-ph

The ELFIN Mission

The Electron Loss and Fields Investigation with a Spatio-Temporal Ambiguity-Resolving option (ELFIN-STAR, or simply: ELFIN) mission comprises two identical 3-Unit (3U) CubeSats on a polar (~93deg inclination), nearly circular, low-Earth (~450 km altitude) orbit. Launched on September 15, 2018, ELFIN is expected to have a >2.5 year lifetime. Its primary science objective is to resolve the mechanism of storm-time relativistic electron precipitation, for which electromagnetic ion cyclotron (EMIC) waves are a prime candidate. From its ionospheric vantage point, ELFIN uses its unique pitch-angle-resolving capability to determine whether measured relativistic electron pitch-angle and energy spectra within the loss cone bear the characteristic signatures of scattering by EMIC waves or whether such scattering may be due to other processes. Pairing identical ELFIN satellites with slowly-variable along-track separation allows disambiguation of spatial and temporal evolution of the precipitation over minutes-to-tens-of-minutes timescales, faster than the orbit period of a single low-altitude satellite (~90min). Each satellite carries an energetic particle detector for electrons (EPDE) that measures 50keV to 5MeV electrons with deltaE/E<40% and a fluxgate magnetometer (FGM) on a ~72cm boom that measures magnetic field waves (e.g., EMIC waves) in the range from DC to 5Hz Nyquist (nominally) with <0.3nT/sqrt(Hz) noise at 1Hz. The spinning satellites (T_spin~3s) are equipped with magnetorquers that permit spin-up/down and reorientation maneuvers. The spin axis is placed normal to the orbit plane, allowing full pitch-angle resolution twice per spin. An energetic particle detector for ions (EPDI) measures 250keV-5MeV ions, addressing secondary science. Funded initially by CalSpace and the University Nanosat Program, ELFIN was selected for flight with joint support from NSF and NASA between 2014 and 2018.

physics.space-ph

Accessible Melanoma Detection using Smartphones and Mobile Image Analysis

We investigate the design of an entire mobile imaging system for early detection of melanoma. Different from previous work, we focus on smartphone-captured visible light images. Our design addresses two major challenges. First, images acquired using a smartphone under loosely-controlled environmental conditions may be subject to various distortions, and this makes melanoma detection more difficult. Second, processing performed on a smartphone is subject to stringent computation and memory constraints. In our work, we propose a detection system that is optimized to run entirely on the resource-constrained smartphone. Our system intends to localize the skin lesion by combining a lightweight method for skin detection with a hierarchical segmentation approach using two fast segmentation methods. Moreover, we study an extensive set of image features and propose new numerical features to characterize a skin lesion. Furthermore, we propose an improved feature selection algorithm to determine a small set of discriminative features used by the final lightweight system. In addition, we study the human-computer interface (HCI) design to understand the usability and acceptance issues of the proposed system.

cs.CV

Direct detection of pure spin-current by x-ray pump-probe measurements

By synchronizing a microwave waveform with the synchrotron x-ray pulses, we use the ferromagnetic resonance (FMR) of the Py (Ni81Fe19) layer in a Py/Cu/Cu75Mn25/Cu/Co multilayer to pump a pure spin current into the Cu75Mn25 spacer layer, and then directly probe the spin current in the Cu75Mn25 layer by a time-resolved x-ray magnetic circular dichroism (XMCD). This element-specific pump-probe measurement unambiguously identifies the AC spin current in the Cu75Mn25 layer. In addition, phase resolved x-ray measurements reveal a characteristic bipolar phase behavior of the Co spins that is a fingerprint of spin-current driven spin precession.

cond-mat.mtrl-sci

The Gaussian CL$_s$ Method for Searches of New Physics

We describe a method based on the CL$_s$ approach to present results in searches of new physics, under the condition that the relevant parameter space is continuous. Our method relies on a class of test statistics developed for non-nested hypotheses testing problems, denoted by $\Delta T$, which has a Gaussian approximation to its parent distribution when the sample size is large. This leads to a simple procedure of forming exclusion sets for the parameters of interest, which we call the Gaussian CL$_s$ method. Our work provides a self-contained mathematical proof for the Gaussian CL$_s$ method, that explicitly outlines the required conditions. These conditions are milder than that required by the Wilks' theorem to set confidence intervals (CIs). We illustrate the Gaussian CL$_s$ method in an example of searching for a sterile neutrino, where the CL$_s$ approach was rarely used before. We also compare data analysis results produced by the Gaussian CL$_s$ method and various CI methods to showcase their differences.

hep-ex

Development of the Liquid Level Meters for the PandaX Dark Matter Detector

The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.

physics.ins-det

Statistical Evaluation of Experimental Determinations of Neutrino Mass Hierarchy

Statistical methods of presenting experimental results in constraining the neutrino mass hierarchy (MH) are discussed. Two problems are considered and are related to each other: how to report the findings for observed experimental data, and how to evaluate the ability of a future experiment to determine the neutrino mass hierarchy, namely, sensitivity of the experiment. For the first problem where experimental data have already been observed, the classical statistical analysis involves constructing confidence intervals for the parameter Δm^2_{32}. These intervals are deduced from the parent distribution of the estimation of Δm^2_{32} based on experimental data. Due to existing experimental constraints on |Δm^2_{32}|, the estimation of Δm^2_{32} is better approximated by a Bernoulli distribution (a Binomial distribution with 1 trial) rather than a Gaussian distribution. Therefore, the Feldman-Cousins approach needs to be used instead of the Gaussian approximation in constructing confidence intervals. Furthermore, as a result of the definition of confidence intervals, even if it is correctly constructed, its confidence level does not directly reflect how much one hypothesis of the MH is supported by the data rather than the other hypothesis. We thus describe a Bayesian approach that quantifies the evidence provided by the observed experimental data through the (posterior) probability that either one hypothesis of MH is true. This Bayesian presentation of observed experimental results is then used to develop several metrics to assess the sensitivity of future experiments. Illustrations are made using a simple example with a confined parameter space, which approximates the MH determination problem with experimental constraints on the |Δm^2_{32}|.

hep-ph