Searcharxiv⌕ Search

arXiv subjects

A. Tarifeño-Saldivia

Publications and source records attributed to A. Tarifeño-Saldivia.

15 recordsLinked to original sources

Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons

Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an experimental investigation of a hybrid Prompt-Gamma Imaging (PGI)--Positron-Emission Tomography (PET) concept at the isochronous cyclotron of the West German Proton Therapy Centre under clinically representative pencil-beam-scanning conditions. Because this accelerator delivers a quasi-continuous beam, a pulsed shoot-and-step structure was imposed to mimic the interruptions associated with clinical energy-layer switching. This enabled PGI during irradiation and PET and delayed Compton imaging during beam-off intervals within the same sequence. Four two-plane Compton cameras were arranged in a co-planar cross-shaped geometry around the beam isocenter. Polyethylene phantoms were irradiated with 100~MeV protons at known positions along the beam axis. Their positions were estimated from reconstructed one-dimensional profiles using supervised machine-learning models trained exclusively on Monte Carlo simulations. PET achieved the best performance, with a root-mean-square deviation of 0.8~mm, followed by PGI with 1.6~mm. Delayed Compton imaging based on e$^{+}$ annihilation photons and $^{10}$C$^{*}$ decays yielded 2.4~mm and 3.8~mm, respectively. PET retained good performance down to 1% of the original event statistics, whereas PGI became increasingly statistics-limited. These results demonstrate the complementary strengths of hybrid PGI--PET and support its development towards millimetre-scale proton-range verification under clinically relevant irradiation conditions.

physics.med-ph↗

Measurement of the ambient neutron flux and spectral distribution at the Canfranc Underground Laboratory

We report on the measurement of the ambient neutron flux and its energy distribution over a broad range of neutron energies, conducted in Hall A of the Canfranc Underground Laboratory using the High Efficiency Neutron Spectrometry Array (HENSA), with a total livetime of 248 days. In particular, we obtained a thermal neutron flux of $3.4(2) \times 10^{-6}$ cm$^{-2}$ s$^{-1}$ and a total energy-integrated flux of $14.8(2) \times 10^{-6}$ cm$^{-2}$ s$^{-1}$. This work represents the first long-term measurement of the ambient neutron flux that includes a full spectral characterization across a wide energy interval (from $10^{-4}$ eV to 20 MeV), performed in an underground laboratory to date. The results are relevant for rare-event search experiments located underground, ranging from nuclear astrophysics to astroparticle physics.

nucl-ex↗

Status of the HENSA collaboration at the Canfranc Underground Laboratory: results from two years of measurement of the neutron flux in hall B

Thiswork deals with the characterization of the neutron flux in hall B of the CanfrancUnderground Laboratory (LSC) employing the High Efficiency Neutron Spectrometry Array (HENSA). The ultimate goal of this measurement is to set a limit on the corresponding effects of the neutron flux in the background of the ANAIS-112 experiment. The preliminary neutron counting rates of two years of measurement are reported. Various data analysis techniques, including pulse shape discrimination, are discussed. The first results on the spectral reconstruction of the neutron flux are also presented.

physics.ins-det↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $γ$-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps toward such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n\_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C$_{6}$D$_{6}$ detectors, and one LaCl$_{3}$(Ce) detector. The performance of these detection systems is compared using $^{93}$Nb($n$,$γ$) data. We also developed a detailed \textsc{Geant4} Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a $γ$ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigaged experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

physics.ins-det↗

Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments

One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.

physics.ins-det↗

Recent highlights and prospects on (n,$γ$) measurements at the CERN n_TOF facility

Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$γ$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.

nucl-ex↗

New detection systems for an enhanced sensitivity in key stellar (n,$γ$) measurements

Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$γ$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$γ$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$γ$).

nucl-ex↗

First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility

One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.

nucl-ex↗

Long-term evolution of the neutron rate at the Canfranc Underground Laboratory

We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-term measurement of the neutron rate with sensitivity over a wide range of neutron energies (from thermal up to 0.1 GeV and beyond) performed in any underground laboratory so far. Data on the environmental variables inside the experimental hall (radon concentration, air temperature, air pressure and humidity) were also acquired during all the measurement campaign. We have investigated for the first time the evolution of the neutron rate for different energies of the neutrons and its correlation with the ambient variables.

nucl-ex↗

Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.

nucl-ex↗

Measurement of the neutron flux at the Canfranc Underground Laboratory with HENSA

We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In Phase 1 (113 live days) a total neutron flux of 1.66(2) $\times$10$^{-5}$ cm$^{-2}$ s$^{-1}$ is obtained. Our results are in good agreement with those from our previous shorter measurement where a reduced experimental setup was employed.

nucl-ex↗

Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques

i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,γ$) and $^{56}$Fe($n, γ$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.

physics.ins-det↗

First determination of $β$-delayed multiple neutron emission beyond A = 100 through direct neutron measurement: The P$_{2n}$ value of $^{136}$Sb

Background: $β$-delayed multiple neutron emission has been observed for some nuclei with A$\leq$100, with $^{100}$Rb being the heaviest $β$2n emitter measured to date. So far, only 25 P$_{2n}$ values have been determined for the $\sim$300 nuclei that may decay in this way. Accordingly, it is of interest to measure P$_{2n}$ values for the other possible multiple neutron emitters throughout the chart of the nuclides. It is of particular interest to make such measurement for nuclei with A$>$100 to test the predictions of theoretical models and simulation tools for the decays of heavy nuclei in the region of very neutron-rich nuclei. In addition, the decay properties of these nuclei are fundamental for the understanding of astrophysical nucleosynthesis processes such as the $r$-process, and safety inputs for nuclear reactors. Purpose: To determine for the first time the two neutron branching ratio, P$_{2n}$ value, for $^{136}$Sb through a direct neutron measurement, and to provide precise P$_{1n}$ values for $^{136}$Sb and $^{136}$Te. Method: Pure beams were provided by the JYFLTRAP at the IGISOL facility of the University of Jyväskylä, Finland. The purified ions were implanted into a moving tape at the end of the beam line. The detection setup consisted of a plastic scintillator placed right behind the implantation point, and the BELEN detector, based on neutron counters embedded in a polyethylene matrix. The analysis was based on the study of the $β$- and neutron- growth-and-decay curves and the $β$-one-neutron and $β$-two-neutron time correlations. Results: The P$_{2n}$ value of $^{136}$Sb was found to be 0.14(3)\% and the measured P$_{1n}$ values for $^{136}$Sb and $^{136}$Te were found to be 32.2(15)\% and 1.47(6)\%, respectively. The measured P$_{2n}$ value is a factor 44 smaller than predicted by the FRDM+QRPA model used for $r$-process calculations.

nucl-ex↗

Conceptual design of the BRIKEN detector: A hybrid neutron-gamma detection system for nuclear physics at the RIB facility of RIKEN

BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, $β$-particles, $γ$-rays and $β$-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-tubes array, aiming at the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected parameters of merit, namely, average neutron detection efficiency and efficiency flatness, as a function of a reduced number of geometric variables. The response of the detection system itself, for each configuration, is obtained from a systematic MC-simulation implemented realistically in Geant4. This approach has been found to be particularly useful. On the one hand, due to the different types and large number of 3He-tubes involved and, on the other hand, due to the additional constraints introduced by the ancillary detectors for charged particles and gamma-rays. Empowered by the robustness of the algorithm, we have been able to design a versatile detection system, which can be easily re-arranged into a compact mode in order to maximize the neutron detection performance, at the cost of the gamma-ray sensitivity. In summary, we have designed a system which shows, for neutron energies up to 1(5) MeV, a rather flat and high average efficiency of 68.6%(64%) and 75.7%(71%) for the hybrid and compact modes, respectively. The performance of the BRIKEN system has been also quantified realistically by means of MC-simulations made with different neutron energy distributions.

physics.ins-det↗

First tests of the applicability of $γ$-ray imaging for background discrimination in time-of-flight neutron capture measurements

In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample.

physics.ins-det↗