SearcharxivSearch

arXiv subjects

A. Tata

Publications and source records attributed to A. Tata.

5 recordsLinked to original sources

A multi-scale approach to the computer-aided detection of microcalcification clusters in digital mammograms

A computer-aided detection (CADe) system for the identification of microcalcification clusters in digital mammograms has been developed. It is mainly based on the application of wavelet transforms for image filtering and neural networks for both the feature extraction and the classification procedures. This CADe system is easily adaptable to different databases. We report and compare the FROC curves obtained on the private database we used for developing the CADe system and on the publicly available MIAS database. The results achieved on the two databases show the same trend, thus demonstrating the good generalization capability of the system.

physics.med-ph

Lung nodule detection in low-dose and high-resolution CT scans

We are developing a computer-aided detection (CAD) system for the identification of small pulmonary nodules in screening CT scans. The main modules of our system, i.e. a dot-enhancement filter for nodule candidate selection and a neural classifier for false positive finding reduction, are described. The preliminary results obtained on the so-far collected database of lung CT are discussed.

physics.med-ph

A scalable system for microcalcification cluster automated detection in a distributed mammographic database

A computer-aided detection (CADe) system for microcalcification cluster identification in mammograms has been developed in the framework of the EU-founded MammoGrid project. The CADe software is mainly based on wavelet transforms and artificial neural networks. It is able to identify microcalcifications in different datasets of mammograms (i.e. acquired with different machines and settings, digitized with different pitch and bit depth or direct digital ones). The CADe can be remotely run from GRID-connected acquisition and annotation stations, supporting clinicians from geographically distant locations in the interpretation of mammographic data. We report and discuss the system performances on different datasets of mammograms and the status of the GRID-enabled CADe analysis.

physics.med-ph

A scalable Computer-Aided Detection system for microcalcification cluster identification in a pan-European distributed database of mammograms

A computer-aided detection (CADe) system for microcalcification cluster identification in mammograms has been developed in the framework of the EU-founded MammoGrid project. The CADe software is mainly based on wavelet transforms and artificial neural networks. It is able to identify microcalcifications in different kinds of mammograms (i.e. acquired with different machines and settings, digitized with different pitch and bit depth or direct digital ones). The CADe can be remotely run from GRID-connected acquisition and annotation stations, supporting clinicians from geographically distant locations in the interpretation of mammographic data. We report the FROC analyses of the CADe system performances on three different dataset of mammograms, i.e. images of the CALMA INFN-founded database collected in the Italian National screening program, the MIAS database and the so-far collected MammoGrid images. The sensitivity values of 88% at a rate of 2.15 false positive findings per image (FP/im), 88% with 2.18 FP/im and 87% with 5.7 FP/im have been obtained on the CALMA, MIAS and MammoGrid database respectively.

physics.med-ph

Pre-processing methods for nodule detection in lung CT

The use of automatic systems in the analysis of medical images has proven to be very useful to radiologists, especially in the framework of screening programs, in which radiologists make their first diagnosis on the basis of images only, most of those corresponding to healthy patients, and have to distinguish pathological findings from non-pathological ones at an early stage. In particular, we are developing preprocessing methods to be applied for pulmonary nodule Computer Aided Detection in low-dose lung Multi Slice CT (Computed Tomography) images.

physics.med-ph