SearcharxivSearch

arXiv subjects

A. Velyhan

Publications and source records attributed to A. Velyhan.

4 recordsLinked to original sources

Relative and absolute dosimetric commissioning of the ELIMAIA--ELIMED laser-driven proton beamline at 23.4 MeV

The development of laser-driven proton beamlines for biomedical and radiobiological applications requires traceable dosimetry and reliable online monitoring at the irradiation point. In this work, we report the relative and absolute dosimetric commissioning of the ELIMAIA--ELIMED laser-driven proton beamline at ELI Beamlines using an energy-selected proton beam with an average energy of about 24~MeV. Radiochromic-film measurements were used to characterize the transverse dose distribution, the depth--dose profile, and the proton energy spectrum at the irradiation point. The reconstructed spectrum was centred at $23.45~\mathrm{MeV}$ with a FWHM of $2.60~\mathrm{MeV}$, while the transverse dose distribution showed an approximately $5.5~\mathrm{mm}$ field size with a millimetre-scale homogeneous region. The Faraday Cup was used as the absolute reference detector for dose to water determination and for cross-calibrating the Dual-Gap Ionization Chamber, which was operated as the primary online dose monitor. The Integrating Current Transformer and Secondary Electron Monitor were evaluated as upstream relative beam monitors. An independent RCF--FC dose comparison performed over fifty consecutive shots yielded $30.45 \pm 3.5~\mathrm{cGy}$ from the FC and $36.46 \pm 1.8~\mathrm{cGy}$ from the EBT3 film. Dedicated G4ELIMED Monte Carlo simulations showed that the RCF positioned upstream of the FC perturbs the FC measurement through proton losses outside the FC acceptance and through an increase in the effective beam area at the FC entrance. Applying the resulting correction factor, $C_{\mathrm{MC}}=1.109$, reduced the residual difference between the FC- and RCF-derived doses to about $7\%$. These results establish the dosimetric chain of the ELIMAIA--ELIMED beamline under the present low-fluence commissioning conditions and identify the operational limits of the online monitoring system.

physics.acc-ph

Demonstration of The Brightest Nano-size Gamma Source

Gamma rays selectively interact with nuclei, induce and mediate nuclear reactions and elementary particle interactions, and exceed x-rays in penetrating power and thus are indispensable for analysis and modification of dense objects. Yet, the available gamma sources lack sufficient power and brightness. The predicted and highly desirable laser-driven gamma flash, from here on termed "Gamma Flash", based on inverse Compton scattering from solid targets at extreme irradiances (>$10^{23}W/cm^2$), would be the highest-power and the brightest terrestrial gamma source with a 30-40% laser-to-gamma energy conversion. However, Gamma Flash remains inaccessible experimentally due to the Bremsstrahlung background. Here we experimentally demonstrate a new interaction regime at the highest effective irradiance where Gamma Flash scaled quickly with the laser power and produced several times the number of Bremsstrahlung photons. Simulations revealed an attosecond, Terawatt Gamma Flash with a nanometre source size achieving a record brightness exceeding $~10^{23}photons/mm^2mrad^2s$ per 0.1% bandwidth at tens of MeV photon energies, surpassing astrophysical Gamma Ray Bursts. These findings could revolutionize inertial fusion energy by enabling unprecedented sub-micrometre/femtosecond resolution radiography of fuel mixing instabilities in extremely-compressed targets. The new gamma source could facilitate significant advances in time-resolved nuclear physics, homeland security, nuclear waste management and non-proliferation, while opening possibilities for spatially-coherent gamma rays.

physics.plasm-ph

Irradiation of luminescence dosimeters in pulsed mixed radiation fields

UHDpulse - Metrology for Advanced Radiotherapy using beams with Ultra-High Pulse Dose Rates is a European project aimed at developing novel dosimetry standards, as well as improving existing ones, for FLASH radiotherapy, very high energy electrons radiotherapy, and laser-driven medical accelerators. Within the scope of this project, Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) detectors are used to measure stray radiation fields. Experiments performed with conventional pulsed particle-beams allow to characterize the dosimeters in known and controllable radiation fields. In turn, this allows to develop models and predict their behavior in complex radiation fields, such as those at laser-driven and FLASH facilities. TL and OSL detectors were irradiated at the Microtron MT25 electron accelerator in Prague, Czech Republic. GAFChromicTM films and plastic nuclear track detectors were used to study the beam profile and the neutron background respectively. The responses of the different detector to the pulsed mixed radiation fields of the Microtron MT25 are compared among each other and presented in this paper.

physics.ins-det

Evidence of resonant surface wave excitation in the relativistic regime through measurements of proton acceleration from grating targets

The interaction of laser pulses with thin grating targets, having a periodic groove at the irradiated surface, has been experimentally investigated. Ultrahigh contrast ($\sim 10^{12}$) pulses allowed to demonstrate an enhanced laser-target coupling for the first time in the relativistic regime of ultra-high intensity $>10^{19} \mbox{W/cm}^{2}$. A maximum increase by a factor of 2.5 of the cut-off energy of protons produced by Target Normal Sheath Acceleration has been observed with respect to plane targets, around the incidence angle expected for resonant excitation of surface waves. A significant enhancement is also observed for small angles of incidence, out of resonance.

physics.plasm-ph