SearcharxivSearch

arXiv subjects

A. Venturini

Publications and source records attributed to A. Venturini.

9 recordsLinked to original sources

The Use of O2 in Gas Mixtures for Drift Chambers

The use of Oxygen in gas mixtures for drift chambers is highly discouraged because Oxygen, being strongly electronegative, is generally believed to lead, even in very small quantities, to extremely reduced drift electron survival probability, thus preventing the detector's operation.The drift chamber of the MEG II experiment at PSI has been operating for several years with a gas mixture that mainly contains He:Isobutane in relative proportions of 90:10% by molar concentration, in addition to 1.5% Isopropanol and 0.5% Oxygen. Oxygen and Isopropanol are essential for the proper functioning of the chamber. The electron attachment in the mixture used has proven negligible for the proper operation of the chamber and agrees well with the Garfield++ simulation after correctly accounting for the three-body attachment simulation.

physics.ins-det

New limit on the μ+->e+γdecay with the MEG II experiment

This letter reports the result of the search for the decay μ+->e+γundertaken at the Paul Scherrer Institut in Switzerland with the MEG II experiment using the data collected in the 2021- 2022 physics runs. The sensitivity of this search is 2.2x10-13, a factor of 2.4 better than that of the full MEG dataset and obtained in a data taking period of about one fourth that of MEG, thanks to the superior performances of the new detector. The result is consistent with the expected background, yielding an upper limit on the branching ratio of B(μ+->e+γ)<1.5 x 10-13 (90 % C.L.). Additional improvements are expected with the data collected during the years 2023-2024. The data-taking will continue in the coming years.

hep-ex

A compact frozen-spin trap for the search for the electric dipole moment of the muon

The electric dipole moments~(EDM) of fundamental particles inherently violate parity~(P) and time-reversal~(T) symmetries. By virtue of the CPT theorem in quantum field theory, the latter also implies the violation of the combined charge-conjugation and parity~(CP) symmetry. We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, \$E \approx 165\$ MV/m, experienced in the rest frame of the muon with a momentum of about 23 MeV/c when it passes through a solenoidal magnetic field of \$|\vec{B}|=2.5\$ T. In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase~I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is 4E-21 ecm. In a subsequent phase, Phase~II, we propose to improve the sensitivity to 6E-23 ecm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 MeV/c}.

hep-ex

Search for the X17 particle in $^{7}\mathrm{Li}(\mathrm{p},\mathrm{e}^+ \mathrm{e}^{-}) ^{8}\mathrm{Be}$ processes with the MEG II detector

The observation of a resonance structure in the opening angle of the electron-positron pairs in the $^{7}$Li(p,\ee) $^{8}$Be reaction was claimed and interpreted as the production and subsequent decay of a hypothetical particle (X17). Similar excesses, consistent with this particle, were later observed in processes involving $^{4}$He and $^{12}$C nuclei with the same experimental technique. The MEG II apparatus at PSI, designed to search for the $μ^+ \rightarrow \mathrm{e}^+ γ$ decay, can be exploited to investigate the existence of this particle and study its nature. Protons from a Cockroft-Walton accelerator, with an energy up to 1.1 MeV, were delivered on a dedicated Li-based target. The $γ$ and the e$^{+}$e$^{-}$ pair emerging from the $^8\mathrm{Be}^*$ transitions were studied with calorimeters and a spectrometer, featuring a broader angular acceptance than previous experiments. We present in this paper the analysis of a four-week data-taking in 2023 with a beam energy of 1080 keV, resulting in the excitation of two different resonances with Q-value \SI{17.6}{\mega\electronvolt} and \SI{18.1}{\mega\electronvolt}. No significant signal was found, and limits at \SI{90}{\percent} C.L. on the branching ratios (relative to the $γ$ emission) of the two resonances to X17 were set, $R_{17.6} < 1.8 \times 10^{-6} $ and $R_{18.1} < 1.2 \times 10^{-5} $.

nucl-ex

Performances of a new generation tracking detector: the MEG II cylindrical drfit chamber

The cylindrical drift chamber is the most innovative part of the MEG~II detector, the upgraded version of the MEG experiment. The MEG~II chamber differs from the MEG one because it is a single volume cylindrical structure, instead of a segmented one, chosen to improve its resolutions and efficiency in detecting low energy positrons from muon decays at rest. In this paper, we show the characteristics and performances of this fundamental part of the MEG~II apparatus and we discuss the impact of its higher resolution and efficiency on the sensitivity of the MEG~II experiment. Because of its innovative structure and high quality resolution and efficiency the MEG~II cylindrical drift chamber will be a cornerstone in the development of an ideal tracking detector for future positron-electron collider machines.

physics.ins-det

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

physics.ins-det

A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

hep-ex

The measuring systems of the wire tension for the MEG II Drift Chamber by means of the resonant frequency technique

The ultra-low mass cylindrical drift chamber designed for the MEG II experiment is a challenging apparatus made of 1728 phi = 20 micron gold plated tungsten sense wires, 7680 phi = 40 micron and 2496 phi = 50 micron silver plated aluminum field wires. Because of electrostatic stability requirements all the wires have to be stretched at mechanical tensions of about 25, 19 and 29 g respectively which must be controlled at a level better than 0.5 g. This chamber is presently in acquisition, but during its construction about 100 field wires broke, because of chemical corrosion induced by the atmospheric humidity. On the basis of the experience gained with this chamber we decided to build a new one, equipped with a different type of wires less sensitive to corrosion. The choice of the new wire required a deep inspection of its characteristics and one of the main tools for doing this is a system for measuring the wire tension by means of the resonant frequency technique, which is described in this paper. The system forces the wires to oscillate by applying a sinusoidal signal at a known frequency, and then measures the variation of the capacitance between a wire and a common ground plane as a function of the external signal frequency. We present the details of the measuring system and the results obtained by scanning the mechanical tensions of two samples of MEG II cylindrical drift chamber wires and discuss the possible improvements of the experimental apparatus and of the measuring technique.

physics.ins-det