SearcharxivSearch

arXiv subjects

A. Waczynski

Publications and source records attributed to A. Waczynski.

4 recordsLinked to original sources

Euclid preparation. Overview of Euclid infrared detector performance from ground tests

The paper describes the objectives, design and findings of the pre-launch ground characterisation campaigns of the Euclid infrared detectors. The pixel properties, including baseline, bad pixels, quantum efficiency, inter pixel capacitance, quantum efficiency, dark current, readout noise, conversion gain, response nonlinearity, and image persistence were measured and characterised for each pixel. We describe in detail the test flow definition that allows us to derive the pixel properties and we present the data acquisition and data quality check software implemented for this purpose. We also outline the measurement protocols of all the pixel properties presented and we provide a comprehensive overview of the performance of the Euclid infrared detectors as derived after tuning the operating parameters of the detectors. The main conclusion of this work is that the performance of the infrared detectors Euclid meets the requirements. Pixels classified as non-functioning accounted for less than 0.2% of all science pixels. IPC coupling is minimal and crosstalk between adjacent pixels is less than 1% between adjacent pixels. 95% of the pixels show a QE greater than 80% across the entire spectral range of the Euclid mission. The conversion gain is approximately 0.52 ADU/e-, with a variation less than 1% between channels of the same detector. The reset noise is approximately equal to 23 ADU after reference pixels correction. The readout noise of a single frame is approximately 13 $e^-$ while the signal estimator noise is measured at 7 $e^-$ in photometric mode and 9 $e^-$ in spectroscopic acquisition mode. The deviation from linear response at signal levels up to 80 k$e^-$ is less than 5% for 95% of the pixels. Median persistence amplitudes are less than 0.3% of the signal, though persistence exhibits significant spatial variation and differences between detectors.

astro-ph.IM

Euclid's Near-Infrared Spectrometer and Photometer ready for flight -- review of final performance

ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $\mu$m range. In this paper, after introducing the survey strategy, we focus our attention on the NISP Data Processing Unit's Application Software, highlighting the experimental process to obtain the final parametrization of the on-board processing of data produced by the array of 16 Teledyne HAWAII-2RG (HgCdTe) detectors. We report results from the latest ground test campaigns with the flight configuration hardware - complete optical system (Korsh anastigmat telescope), detectors array (0.56 deg$^2$ field of view), and readout systems (16 Digital Control Units and Sidecar ASICs). The performance of the on-board processing is then presented. We also describe a major issue found during the final test phase. We show how the problem was identified and solved thanks to an intensive coordinated effort of an independent review `Tiger' team, lead by ESA, and a team of NISP experts from the Euclid Consortium. An extended PLM level campaign at ambient temperature in Li\`ege and a dedicated test campaign conducted in Marseille on the NISP EQM model eventually confirmed the resolution of the problem. Finally, we report examples of the outstanding spectrometric (using a Blue and two Red Grisms) and photometric performance of the NISP instrument, as derived from the end-to-end payload module test campaign at FOCAL 5 -- CSL; these results include the photometric Point Spread Function (PSF) determination and the spectroscopic dispersion verification.

astro-ph.IM

Euclid Near Infrared Spectrometer and Photometer instrument flight model presentation, performance and ground calibration results summary

The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal control system, a detection system based on a mosaic of 16 H2RG with their front-end readout electronic, and a warm electronic system (290 K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data. This paper presents: the final architecture of the flight model instrument and subsystems, and the performance and the ground calibration measurement done at NISP level and at Euclid Payload Module level at operational cold temperature.

astro-ph.IM

Inter-Pixel Crosstalk in Teledyne Imaging Sensors (TIS) H4RG-10 Detectors

CMOS-hybrid arrays have recently surfaced as competitive optical detectors for use in ground- and space-based astronomy. One source of error in these detectors that does not appear in more traditional CCD arrays is the inter-pixel capacitance component of crosstalk. In this paper we use a single pixel reset method to model inter-pixel capacitance (IPC). We combine this IPC model with a model for charge diffusion to estimate the total crosstalk on H4RG arrays. Finally, we compare our model results to Fe55 data obtained using an astrometric camera built to test the H4RG-B0 generation detectors.

astro-ph.IM