Searcharxiv⌕ Search

arXiv subjects

Abdulaziz Qwbaiban

Publications and source records attributed to Abdulaziz Qwbaiban.

5 recordsLinked to original sources

The Price of a Cycle: A Phasor -vs- Sampled-Value Comparison for Streaming Fault Classification on the IEEE 9-Bus System

Transmission-line fault classification is a time-critical protection function, and recent machine-learning methods classify fault type directly from voltage and current measurements. The input to such a classifier can be supplied as sampled-value windows of raw measurements, which preserve sub-cycle structure, or as phasor-domain sequence components, which are physically interpretable but require a causal one-cycle observation window before a phasor estimate is available. This paper measures the cost of that observation window, the price of a cycle, through a controlled comparison of the two representations for streaming fault-family classification on the standard synchronous WSCC/IEEE 9-bus system. The comparison holds the simulated system, the measured channels, the eleven-class event-family taxonomy, the training procedure, and the streaming decision layer constant, and uses six configurations: 40- and 80-sample sampled-value inputs and one-cycle phasor inputs, each evaluated with a multilayer perceptron (MLP) and a one-dimensional convolutional neural network (CNN). All six configurations classify every event successfully, yet the sampled-value representation reaches the correct class earlier in every model pair. The 40-sample sampled-value MLP attains the strongest result, with 99.34% fault-window accuracy, 99.79% normal accuracy, a 0.21% false-fault rate, a 0.65% false-normal rate, and a 2.81 ms mean first-correct delay, and it Pareto-dominates the other five configurations. A matched-window comparison at eighty samples confirms that the timing advantage follows from the representation rather than from the window length. On this clean synchronous benchmark, the one-cycle phasor representation does not return an accuracy or stability benefit sufficient to offset its delay.

eess.SY↗

One-Cycle Fault Classification and Faulted-Line Identification on the PROTECT-90 Dataset: An Initial Application Benchmark

Open electromagnetic-transient datasets are beginning to make reproducible learning-based protection studies possible, but the practical use of these datasets still requires application-level benchmarks that define timing, sensing, and validation assumptions. This paper presents an initial application benchmark on the recently released PROTECT-90 dataset for two protection-oriented tasks: fault-type classification and discrete faulted-line identification. A compact one-dimensional convolutional neural network (CNN) is evaluated using post-inception windows of 0.25, 0.5, 1, and 2 cycles under strict episode-wise splitting. A non-convolutional multilayer perceptron (MLP) is also trained as an architecture-control baseline. The results show that both tasks are nearly saturated under full observability, with one-cycle test accuracies of 99.84% for fault type and 100.00% for line identification. The main performance variation appears under reduced observability: current-only inputs preserve line identification accuracy at 100.00%, whereas voltage-only inputs reduce line identification accuracy to 53.09% with the CNN and 50.57% with the MLP. This indicates that the limiting factor is measurement information rather than neural architecture. Additional stratified checks show stable performance across topology states and fault-resistance bins, while CPU inference contributes only 0.528 ms to the one-cycle total decision time of 20.53 ms.

eess.SY↗

Voltage and Frequency Stability Analysis of Transmission Power Grids with EV Charging Stations

The large-scale Electric Vehicle (EV) integration into the electricity grid has initiated significant challenges to grid stability issues due to dynamic loadability events. Although electric vehicle impacts on distribution systems are well studied, transmission-level investigations remain limited. In this research paper, case scenarios of EV load models as charging stations have been considered for stability analysis (Voltage and Frequency Stability) to address EV operation on the transmission grid. It is also noted that the operation of EV stations due to their high loadability causes more stability complexities to the grid compared to other loads in a power network. Simulations have been conducted on two different power networks of the IEEE-9 and IEEE-39 bus test systems, respectively.

eess.SY↗

The Wisdom of the Crowd: High-Fidelity Classification of Cyber-Attacks and Faults in Power Systems Using Ensemble and Machine Learning

This paper presents a high-fidelity evaluation framework for machine learning (ML)-based classification of cyber-attacks and physical faults using electromagnetic transient simulations with digital substation emulation at 4.8 kHz. Twelve ML models, including ensemble algorithms and a multi-layer perceptron (MLP), were trained on labeled time-domain measurements and evaluated in a real-time streaming environment designed for sub-cycle responsiveness. The architecture incorporates a cycle-length smoothing filter and confidence threshold to stabilize decisions. Results show that while several models achieved near-perfect offline accuracies (up to 99.9%), only the MLP sustained robust coverage (98-99%) under streaming, whereas ensembles preserved perfect anomaly precision but abstained frequently (10-49% coverage). These findings demonstrate that offline accuracy alone is an unreliable indicator of field readiness and underscore the need for realistic testing and inference pipelines to ensure dependable classification in inverter-based resources (IBR)-rich networks.

eess.SY↗

Centralized Dynamic State Estimation Algorithm for Detecting and Distinguishing Faults and Cyber Attacks in Power Systems

As power systems evolve with increased integration of renewable energy sources, they become more complex and vulnerable to both cyber and physical threats. This study validates a centralized Dynamic State Estimation (DSE) algorithm designed to enhance the protection of power systems, particularly focusing on microgrids with substantial renewable energy integration. The algorithm utilizing a structured hypothesis testing framework, systematically identifies and differentiates anomalies caused by cyberattacks from those resulting from physical faults. This algorithm was evaluated through four case studies: a False Data Injection Attack (FDIA) via manipulation of Current Transformer (CT) ratios, a single line-to-ground (SLG) fault, and two combined scenarios involving both anomalies. Results from real-time simulations demonstrate that the algorithm effectively distinguishes between cyber-induced anomalies and physical faults, thereby significantly enhancing the reliability and security of energy systems. This research underscores the critical role of advanced diagnostic tools in protecting power systems against the growing prevalence of cyber-physical threats, enhancing the resilience of the grid and preventing potential blackouts by avoiding the mis-operation of protection relays.

eess.SY↗