SearcharxivSearch

arXiv subjects

Abishek Karki

Publications and source records attributed to Abishek Karki.

3 recordsLinked to original sources

The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab

We report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting (quasi-) elastically scattered electrons in the 1-4 GeV energy range with an energy resolution of approximately 6.2%, position resolution of 1.2 cm, and timing resolution of 0.5 ns.

physics.ins-det

New Measurements of the Deuteron to Proton F2 Structure Function Ratio

Nucleon structure functions, as measured in lepton-nucleon scattering, have historically provided a critical observable in the study of partonic dynamics within the nucleon. However, at very large parton momenta it is both experimentally and theoretically challenging to extract parton distributions due to the probable onset of non-perturbative contributions and the unavailability of high precision data at critical kinematics. Extraction of the neutron structure and the d-quark distribution have been further challenging due to the necessity of applying nuclear corrections when utilizing scattering data from a deuteron target to extract free neutron structure. However, a program of experiments has been carried out recently at the energy-upgraded Jefferson Lab electron accelerator aimed at significantly reducing the nuclear correction uncertainties on the d-quark distribution function at large partonic momentum. This allows leveraging the vast body of deuterium data covering a large kinematic range to be utilized for d-quark parton distribution function extraction. We present new data from experiment E12-10-002 carried out in Jefferson Lab Hall C on the deuteron to proton cross-section ratio at large BJorken-x. These results significantly improve the precision of existing data, and provide a first look at the expected impact on quark distributions extracted from global parton distribution function fits.

hep-ex

Divergent Clinical Equivalence Findings from DVH and NTCP Metrics for Alternative OAR Delineations with Increasing Setup Variability in Head-and-Neck Radiotherapy

Purpose: This study quantifies the variation in dose-volume histogram (DVH) and normal tissue complication probability (NTCP) metrics for head-and-neck (HN) cancer patients when alternative organ-at-risk (OAR) delineations are used for treatment planning and for treatment plan evaluation. We particularly focus on the effects of daily patient positioning/setup variations (SV) in relation to treatment technique and delineation variability. Materials and Methods: We generated two-arc VMAT, 5-beam IMRT, and 9-beam IMRT treatment plans for a cohort of 209 HN patients. These plans incorporated five different OAR delineation sets, including manual and four automated algorithms. Each treatment plan was assessed under various simulated per-fraction patient setup uncertainties, evaluating the potential clinical impacts through DVH and NTCP metrics. Results: The study demonstrates that increasing setup variability generally reduces differences in DVH metrics between alternative delineations. However, in contrast, differences in NTCP metrics tend to increase with higher setup variability. This pattern is observed consistently across different treatment plans and delineator combinations, illustrating the intricate relationship between SV and delineation accuracy. Additionally, the need for delineation accuracy in treatment planning is shown to be case-specific and dependent on factors beyond geometric variations. Conclusions: The findings highlight the necessity for comprehensive quality assurance programs in radiotherapy, incorporating both dosimetric impact analysis and geometric variation assessment to ensure optimal delineation quality. The study emphasizes the complex dynamics of treatment planning in radiotherapy, advocating for personalized, case-specific strategies in clinical practice to enhance patient care quality and efficacy in the face of varying SV and delineation accuracies.

physics.med-ph