Searcharxiv⌕ Search

arXiv subjects

Adrienne M. Juett

Publications and source records attributed to Adrienne M. Juett.

21 records · Page 2Linked to original sources

Chandra High-Resolution Spectrum of the Anomalous X-ray Pulsar 4U 0142+61

We report on a 25 ks observation of the 8.7 s anomalous X-ray pulsar 4U~0142+61 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory. The continuum spectrum is consistent with previous measurements and is well fit by an absorbed power-law + blackbody with photon index Gamma=3.3+/-0.4 and kT=0.418+/-0.013 keV. No evidence was found for emission or absorption lines, with an upper limit of ~50 eV on the equivalent width of broad features in the 2.5-13 A (0.95-5.0 keV) range and an upper limit of ~10 eV on the equivalent width of narrow features in the 4.1-17.7 A (0.7-3.0 keV) range. If the source is a magnetar, then the absence of a proton cyclotron line strongly constrains magnetar atmosphere models and hence the magnetic field strength of the neutron star. We find no strong features that are indicative of cyclotron absorption for magnetic field strengths of (1.9-9.8)x10^{14} G. This is still consistent with the dipole field strength of B=1.3x10^{14} G (at the polar cap) estimated from the pulsar's spindown.

astro-ph↗

Chandra/HETGS Spectroscopy of the Anomalous X-ray Pulsar 4U 0142+61

We report on a 25 ks observation of the anomalous X-ray pulsar 4U 0142+61 with the High Energy Transmission Grating Spectrometer (HETGS) on the Chandra X-ray Observatory. The continuum spectrum is consistent with previous measurements and is well fit by an absorbed power-law + blackbody model with photon index Gamma=3.3+/-0.4 and blackbody temperature kT=0.418+/-0.013 keV. The pulsar frequency was 0.1150966+/-0.0000017 Hz and the pulse fractions were between 8.7% and 21%, which are also consistent with past measurements. No evidence was found for emission or absorption lines with an upper limit of ~50 eV on the equivalent width of a broad feature in the 2.5-13 A (0.95-4.96 keV) range. The absence of a proton cyclotron line strongly constrains magnetar atmosphere models and hence the magnetic field strength of the neutron star. For the energy range given above, the allowed magnetic field strengths of 4U 0142+61 are B<1.9x 10^14 G and B>9.8x 10^14 G.

astro-ph↗

Ultracompact X-Ray Binaries with Neon-Rich Degenerate Donors

There are three low-mass X-ray binaries (4U 0614+091, 2S 0918-549, and 4U 1543-624) for which broad line emission near 0.7 keV was previously reported. A recent high-resolution observation of 4U 0614+091 with the Chandra/LETGS found evidence for an unusually high Ne/O abundance ratio along the line of sight but failed to detect the previously reported 0.7 keV feature. We have made a search of archival ASCA spectra and identified a fourth source with the 0.7 keV feature, the 20-min ultracompact binary 4U 1850-087. In all four of these sources, the 0.7 keV residual is eliminated from the ASCA spectra by allowing excess photoelectric absorption due to a non-solar relative abundance of neon, just as in the LETGS spectrum of 4U 0614+091. The optical properties of these systems suggest that all four are ultracompact (P_orb<80 min) binaries. We propose that there is excess neon local to each of these sources, as also found in the ultracompact binary pulsar 4U 1626-67. We suggest that the mass donor in these systems is a low-mass, neon-rich degenerate dwarf and that the binaries are all ultracompact.

astro-ph↗