SearcharxivSearch

arXiv subjects

Aharon Blank

Publications and source records attributed to Aharon Blank.

13 recordsLinked to original sources

Solid-State Maser with Microwatt Output Power at Moderate Cryogenic Temperatures

Solid-state masers are uniquely positioned to serve as ultra-low phase noise microwave sources due to their exceptionally low noise temperatures. However, their practical application has been historically limited by low output power and the need for deep cryogenic cooling. In this work, we present a novel design for a continuous-wave diamond-based maser oscillator operating at about 14.5 GHz and moderate cryogenic temperatures (about 180 K), achieving output power levels exceeding -30 dBm (1 microW). This performance represents a two-orders-of-magnitude improvement over previous diamond or ruby-based maser oscillators.Our system integrates a high-Q (about 2460) compact metallic microwave cavity with optically pumped (111)-oriented NV-rich diamond crystals. The cavity supports efficient light coupling and thermal dissipation, enabling sustained high-power optical excitation (>1 W) using cost-effective green LEDs. We demonstrate stable maser operation with good spectral quality and validate its output through both frequency- and time-domain analysis with phase noise data when operated in "free running" mode. Additionally, we provide phase noise estimations based on Leeson's model and show that, when coupled to a high-Q external resonator, such masers could approach thermally limited phase noise levels. These predictions suggest strong potential for diamond masers to outperform traditional ruby-based or similar maser systems, especially given their ability to operate at higher temperatures using rugged, He-free Stirling coolers. Despite current limitations related to frequency stability and jitter, this work establishes diamond-based masers as promising candidates for next-generation ultra-low phase noise microwave oscillators. Further engineering optimization - particularly in field stability, thermal regulation, and feedback locking - will be key to unlocking their full potential.

cond-mat.other

Nonlinear Broadband THz Generation from NV Centers in Bulk Diamond Crystals

Diamond single crystals are promising nonlinear THz sources due to their high damage threshold, transparency, and small dispersion linear dispersion over THz-NIR which enables relaxing the need for additional phase-matching engineering . However, the centrosymmetry of a diamond's lattice prohibits even-order nonlinear effects, including second harmonic generation and optical rectification. We demonstrate broadband THz emission via optical rectification in an NV-doped diamond, where NV centers break inversion symmetry and induce a nonlinear susceptibility in the lattice. THz time-domain spectroscopy reveals single-cycle emission spanning over 4 THz bandwidth, enabled by a high NV density (~200 ppm) and lattice strain. Density functional theory (DFT) confirms the emergence of finite second-order nonlinear susceptibility, directly linking symmetry breaking to THz generation. The wide bandgap and defect-induced strain support efficient THz emission without crystal damage, establishing NV-diamond as a robust platform for high-field ultrabroadband THz generation.

physics.optics

Cryogenic W-band Electron Spin Resonance Probehead with an Integral Cryogenic Low Noise Amplifier

The quest to enhance the sensitivity of electron spin resonance (ESR) is an ongoing challenge. One potential strategy involves increasing the frequency, for instance, moving from Q-band (approximately 35 GHz) to W-band (approximately 94 GHz). However, this shift typically results in higher transmission and switching losses, as well as increased noise in signal amplifiers. In this work, we address these shortcomings by employing a W-band probehead integrated with a cryogenic low-noise amplifier (LNA) and a microresonator. This configuration allows us to position the LNA close to the resonator, thereby amplifying the acquired ESR signal with minimal losses. Furthermore, when operated at cryogenic temperatures, the LNA exhibits unparalleled noise levels that are significantly lower than those of conventional room temperature LNAs. We detail the novel probehead design and provide some experimental results at room temperature as well as cryogenic temperatures for representative paramagnetic samples. We find, for example, that spin sensitivity of ~3*10^5 spins/sqrt(Hz) is achieved for a sample of phosphorus doped 28Si, even for sub-optimal sample geometry with potential improvement to <10^3 spins/sqrt(Hz) in more optimal scenarios.

physics.chem-ph

Extending Radiowave Frequency Detection Range with Dressed States of Solid-State Spin Ensembles

Quantum sensors using solid-state spin defects excel in the detection of radiofrequency (RF) fields, serving various purposes in communication, ranging, and sensing. For this purpose, pulsed dynamical decoupling (PDD) protocols are typically applied, which enhance sensitivity to RF signals. However, these methods are limited to frequencies of a few megahertz, which poses a challenge for sensing higher frequencies. We introduce an alternative approach based on a continuous dynamical decoupling (CDD) scheme involving dressed states of nitrogen vacancy (NV) ensemble spins driven within a microwave resonator. We compare the CDD methods to established PDD protocols and demonstrate the detection of RF signals up to $\sim$ 85 MHz, about ten times the current limit imposed by the PDD approach under identical conditions. Implementing the CDD method in a heterodyne synchronized protocol combines the high frequency detection with high spectral resolution. This advancement extends to various domains requiring detection in the high frequency (HF) and very high frequency (VHF) ranges of the RF spectrum, including spin sensor-based magnetic resonance spectroscopy at high magnetic fields.

physics.app-ph

An anti-maser for quantum-limited cooling of a microwave cavity

The maser, a microwave (MW) analog of the laser, is a well-established method for generating and amplifying coherent MW irradiation with ultra-low noise. This is accomplished by creating a state of population inversion between two energy levels separated by MW frequency. Thermodynamically, such a state corresponds to a small but negative temperature. The reverse condition, where only the lower energy level is highly populated, corresponds to a very low positive temperature. In this work, we experimentally demonstrate how to generate such a state in condensed matter at moderate cryogenic temperatures. This state is then used to efficiently remove microwave photons from a cavity, continuously cooling it to the quantum limit, well below its ambient temperature. Such an "anti-maser" device could be extremely beneficial for applications that would normally require cooling to millikelvin temperatures to eliminate any MW photons. For instance, superconducting MW quantum circuits (such as qubits and amplifiers) could, with the use of this device, operate efficiently at liquid helium temperatures.

quant-ph

Superconducting microresonators for electron spin resonance, the good, the bad, and the future

The field of electron spin resonance is in constant need to improve its capabilities. Among other things, this means having better resonators which would provide improved spin sensitivity, as well as enable larger microwave magnetic field power conversion factors. Surface micro resonators, made of small metallic patches on a dielectric substrate, provide very good absolute spin sensitivity and high conversion factors due to their very small mode volume. However, such resonators suffer from having a relatively low quality factor, which offsets some of their significant potential advantages. The use of superconducting patches to replace the metallic layer seems like a reasonable and straightforward solution to the quality factor issue, at least for measurements carried out at cryogenic temperatures. Nevertheless, superconducting materials are not easily incorporated into setups requiring high magnetic fields, due to electric current vortices generated in the latter's surface. This makes the transition from normal conducing materials to superconductors highly nontrivial. Here we present the design, fabrication, and testing results of surface micro resonators made of yttrium barium copper oxide (YBCO) superconducting material. We show that with a unique experimental setup, these resonators can be made to operate well even at high fields of about 1.2 T. Furthermore, we analyze the effect of current vortices on the ESR signal and the spins' coherence times. Finally, we provide a head to head comparison of YBCO vs copper resonators of the same dimensions, which clearly shows their pros and cons and directs us to future potential developments and improvements in this field.

physics.chem-ph

Selective Noise Resistant Gate

Realizing individual control on single qubits in a spin-based quantum register is an ever-increasing challenge due to the close proximity of the qubits resonance frequencies. Current schemes typically suffer from an inherent trade-off between fidelity and qubits selectivity. Here, we report on a new scheme which combines noise protection by dynamical decoupling and magnetic gradient based selectivity, to enhance both the fidelity and the selectivity. With a single nitrogen-vacancy center in diamond, we experimentally demonstrate quantum gates with fidelity = 0.9 $\pm$ 0.02 and a 50 kHz spectral bandwidth, which is almost an order of magnitude narrower than the unprotected bandwidth. Our scheme will enable selective control of an individual nitrogen-vacancy qubit in an interacting qubits array using relatively moderate gradients of about 1 mG/nm.

quant-ph

Optically Detected Magnetic Resonance Imaging

Optically detected magnetic resonance (ODMR) provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in this field, it has never been combined with the power of pulsed magnetic resonance imaging (MRI) techniques. Here, we demonstrate for the first time how these two methodologies can be integrated using short pulsed magnetic field gradients to spatially-encode the sample. This results in what we denote as an "optically detected magnetic resonance imaging" (ODMRI) technique. It offers the advantage that the image is acquired in parallel from all parts of the sample, with well-defined three-dimensional point-spread function, and without any loss of spectroscopic information. In addition, this approach may be used in the future for parallel but yet spatially-selective efficient addressing and manipulation of the spins in the sample. Such capabilities are of fundamental importance in the field of quantum spin-based devices and sensors.

cond-mat.mes-hall

High Resolution Microimaging with Pulsed Electrically-Detected Magnetic Resonance

The investigation of paramagnetic species (such as point defects, dopants, and impurities) in solid-state electronic devices is significant because of their effect on device performance. Conventionally, these species are detected and imaged using the electron spin resonance (ESR) technique. In many instances, ESR is not sensitive enough to deal with miniature devices having small numbers of paramagnetic species and high spatial heterogeneity. This limitation can in principle be overcome by employing a more sensitive method called electrically-detected magnetic resonance, which is based on measuring the effect of paramagnetic species on the electric current of the device while inducing electron spin-flip transitions. However, up until now, measurement of the current of the device could not reveal the spatial heterogeneity of its paramagnetic species. We provide here, for the first time, high resolution microimages of paramagnetic species in operating solar cells obtained through electrically-detected magnetic resonance. The method is based on unique microwave pulse sequences for excitation and detection of the electrical signal under a static magnetic field and powerful pulsed magnetic field gradients that spatially encode the electrical current of the sample. The approach developed here can be widely used in the nondestructive three-dimensional inspection and characterization of paramagnetic species in a variety of electronic devices.

cond-mat.mtrl-sci

Induction-Detection Electron Spin Resonance with Sensitivity of 1000 Spins: En Route to Scalable Quantum Computations

Spin-based quantum computation (QC) in the solid state is considered to be one of the most promising approaches to scalable quantum computers. However, it faces problems such as initializing the spins, selectively addressing and manipulating single spins, and reading out the state of the individual spins. We have recently sketched a scheme that potentially solves all of these problems5. This is achieved by making use of a unique phosphorus-doped 28Si sample (28Si:P), and applying powerful new electron spin resonance (ESR) techniques for parallel excitation, detection, and imaging in order to implement QCs and efficiently obtain their results. The beauty of our proposed scheme is that, contrary to other approaches, single-spin detection sensitivity is not required and a capability to measure signals of ~100-1000 spins is sufficient to implement it. Here we take the first experimental step towards the actual implementation of such scheme. We show that, by making use of the smallest ESR resonator constructed to date (~5 microns), together with a unique cryogenic amplification scheme and sub-micron imaging capabilities, a sensitivity of less than 1000 electron spin is obtained with spatial resolution of ~500 nm. This is the most sensitive induction-detection experiment carried out to date, and such capabilities put this approach on the fast track to the demonstration of a scalable QC capability.

physics.ins-det

Scheme for a spin-based quantum computer employing induction detection and imaging

A theoretical spin-based scheme for performing a variety of quantum computations is presented. It makes use of an array of multiple identical computer vectors of phosphorus-doped silicon where the nuclei serve as logical qubits and the electrons as working qubits. The spins are addressed by a combination of electron spin resonance and nuclear magnetic resonance techniques operating at a field of ~3.3 T and cryogenic temperatures with an ultra-sensitive surface microresonator. Spin initialization is invoked by a combination of strong pre-polarization fields and laser pulses, which shortens the electrons' T1. The set of universal quantum gates for this system includes an arbitrary rotation of single qubits and c-NOT operation in two qubits. The efficient parallel readout of all the spins in the system is performed by high sensitivity induction detection of the electron spin resonance signals with one-dimensional imaging. Details of the suggested scheme are provided, which show that it is scalable to a few hundreds of qubits.

quant-ph

Nonlinear Induction Detection of Electron Spin Resonance

We present a new approach to the induction detection of electron spin resonance (ESR) signals exploiting the nonlinear properties of a superconducting resonator. Our experiments employ a yttrium barium copper oxide (YBCO) superconducting stripline microwave (MW) resonator integrated with a microbridge. A strong nonlinear response of the resonator is thermally activated in the microbridge when exceeding a threshold in the injected MW power. The responsivity factor characterizing the ESR-induced change in the system's output signal is about 100 times larger when operating the resonator near the instability threshold, compared to the value obtained in the linear regime of operation. Preliminary experimental results, together with a theoretical model of this phenomenon are presented. Under appropriate conditions nonlinear induction detection of ESR can potentially improve upon the current capabilities of conventional linear induction detection ESR.

cond-mat.mes-hall

Power Laws and Cities Population

We study a few dynamical systems composed of many components whose sizes evolve according to multiplicative stochastic rules. We compare them with respect to the emergence of power laws in the size distribution of their components. We show that the details specifying and enforcing the smallest size of the components are crucial as well as the rules for creating new components. In the systems where the power law holds, one obtains for the exponent alpha the experimentally measured value 1 for a wide range of parameters.

cond-mat.stat-mech