SearcharxivSearch

arXiv subjects

Ahmad Zaraket

Publications and source records attributed to Ahmad Zaraket.

3 recordsLinked to original sources

Readout electronics for SUBMET

A dedicated data acquisition (DAQ) system has been developed for the SUB-Millicharge ExperimenT (SUBMET) at the Japan Proton Accelerator Research Complex (J-PARC), a search for particles carrying a fractional electric charge $Q = \epsilon e$ with $\epsilon$ below $\mathcal{O}(10^{-3})$, hereafter referred to as millicharged particles (mCPs). Because such particles are expected to produce at most a few scintillation photons, the system is optimized for single-photoelectron detection from the photomultiplier tubes (PMTs), combining high-speed waveform digitization with precise timing. To capture eight consecutive proton bunches of the 30 GeV J-PARC beam within a single trigger, the eight channels of the Domino Ring Sampler 4 (DRS4) chip are cascaded in groups of four to form two readout inputs, each sampling 4096 points continuously at 820.5 MHz over an effective time window of 5 us. After calibration, timing differences between channels are within 1 ns on the same DRS4 chip, 2 ns on the same board, and 8 ns across different boards, well within the 30 ns coincidence window of the experiment. The front-end electronics achieve an RMS noise below 0.4 mV. The baseline is deliberately offset upward such that the negative-going pulses span a larger fraction of the digitizer range, improving voltage resolution and dynamic range. A trigger control board aggregates data from multiple readout boards and sustains the data-transfer rate required for beam operation. The measured performance confirms that the DAQ system meets the timing, noise, and throughput requirements of the experiment.

hep-ex

Afterpulse prediction for SUBMET experiment

The SUB-Millicharge ExperimenT (SUBMET) investigates an unexplored parameter space of millicharged particles with mass $m_\chi < $ 1.6 GeV/c$^2$ and charge $Q_\chi < 10^{-3}e$. The detector consists of an Eljen-200 plastic scintillator coupled to a Hamamatsu Photonics R7725 photomultiplier tube (PMT). PMT afterpulses, delayed pulses produced after an energetic pulse, have been observed in the SUBMET readout system, especially following primary pulses with a large area. We present a prediction method for afterpulse rates based on measurable parameters, which reproduces the observed rate with approximately 20\% precision. This approach enables a better understanding of afterpulse contributions and, consequently, improves the reliability of background predictions.

physics.ins-det

Design and Mechanical Integration of Scintillation Modules for SUB-Millicharge ExperimenT (SUBMET)

We present a detailed description of the detector design for the SUB-Millicharge ExperimenT (SUBMET), developed to search for millicharged particles. The experiment probes a largely unexplored region of the charge-mass parameter space, focusing on particles with mass $m_\chi < 1.6~\textrm{GeV}/c^2$ and electric charge $Q < 10^{-3}e$. The detector has been optimized to achieve high sensitivity to interactions of such particles while maintaining effective discrimination against background events. We provide a comprehensive overview of the key detector components, including scintillation modules, photomultiplier tubes, and the mechanical support structure.

physics.ins-det