SearcharxivSearch

arXiv subjects

Aki Kallonen

Publications and source records attributed to Aki Kallonen.

3 recordsLinked to original sources

Shape recovery from sparse tomographic X-ray data

A two-dimensional tomographic problem is studied. The target is assumed to be a homogeneous object bounded by a smooth curve. A Non Uniform Rational Basis Splines (NURBS) curve is used as computational representation of the boundary. This approach conveniently provides the result in a format readily compatible with computer-aided design (CAD) software. However, the linear tomography task becomes a nonlinear inverse problem due to the NURBS-based parameterization. Therefore, Bayesian inversion with Markov chain Monte Carlo (MCMC) sampling is used for calculating an estimate of the NURBS control points. The reconstruction method is tested with both simulated data and measured X-ray projection data. The proposed method recovers the shape and the attenuation coefficient significantly better than the baseline algorithm (optimally thresholded total variation regularization), but at the cost of heavier computation.

math.NA

Tomographic X-ray data of a walnut

This is the documentation of the tomographic X-ray data of a walnut made available at http://www.fips.fi/dataset.php . The data can be freely used for scientific purposes with appropriate references to the data and to this document in arXiv. The data set consists of (1) the X-ray sinogram of a single 2D slice of the walnut with three different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 120-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution. In addition, a larger set of 1200 projections of the same walnut was measured and a high-resolution filtered back-projection reconstruction was computed from this data; both the sinogram and the FBP reconstruction are included in the data set, the latter serving as a ground truth reconstruction.

physics.data-an

Multi-resolution parameter choice method for total variation regularized tomography

A computational method is introduced for choosing the regularization parameter for total variation (TV) regularization. The approach is based on computing reconstructions at a few different resolutions and various values of regularization parameter. The chosen parameter is the smallest one resulting in approximately discretization-invariant TV norms of the reconstructions. The method is tested with X-ray tomography data measured from a walnut and compared to the S-curve method. The proposed method seems to automatically adapt to the desired resolution and noise level, and it yields useful results in the tests. The results are comparable to those of the S-curve method; however, the S-curve method needs a priori information about the sparsity of the unknown, while the proposed method does not need any a priori information (apart from the choice of a desired resolution). Mathematical analysis is presented for (partial) understanding of the properties of the proposed parameter choice method. It is rigorously proven that the TV norms of the reconstructions converge with any choice of regularization parameter.

math.NA