SearcharxivSearch

arXiv subjects

Albert Young

Publications and source records attributed to Albert Young.

8 recordsLinked to original sources

Pendellösung Interferometry Probes the Neutron Charge Radius, Lattice Dynamics, and Fifth Forces

Structure factors describe how incident radiation is scattered from materials such as silicon and germanium and characterize the physical interaction between the material and scattered particles. We use neutron pendellösung interferometry to make precision measurements of the (220) and (400) neutron-silicon structure factors, and achieve a factor of four improvement in the (111) structure factor uncertainty. These data provide measurements of the silicon Debye-Waller factor at room temperature and the mean square neutron charge radius $\langle r_n^2 \rangle = -0.1101 \pm 0.0089 \, \mathrm{fm}^2$. Combined with existing measurements of the Debye-Waller factor and charge radius, the measured structure factors also improve constraints on the strength of a Yukawa-modification to gravity by an order of magnitude over the 20 pm to 10 nm length scale range.

nucl-ex

Incoherent approximation for neutron up-scattering cross sections and its corrections for slow neutrons and low crystal temperatures

The incoherent approximation (IA) is often used for calculating the one-phonon inelastic neutron scattering cross section for arbitrary solids. It is valid for thermal neutrons but for slow neutrons it requires a correction, which is significant for isotopes that are strong coherent scatterers. In this article, we present the extension of the Placzek--Van Hove corrections for slow neutrons in the limit of low temperatures using the example of solid \emph{ortho}-deuterium (sD$_2$). Our approach yields realistic one-phonon up-scattering cross sections for sD$_2$ and shows the IA to be a factor of 2 to 5 too high for ultracold neutron (UCN) up-scattering in sD$_2$. Our calculations are compared with previously published Monte Carlo calculations of the one-phonon cross section based on the dynamic structure function $S(q,ω)$ of polycrystalline \emph{ortho}-deuterium and are found to be consistent with them. Furthermore, we provide the means for easily replicable calculations of the one-phonon up-scattering cross sections of solid \emph{ortho}-deuterium for slow neutrons. These should from now on be used in calculations and simulations of UCN scattering in sD$_2$.

nucl-th

A look into mirrors: A measurement of the $β$-asymmetry in $^{19}$Ne decay and searches for new physics

High precision measurements of isospin $T=1/2$ decays in the neutron and nuclei provide strong model-independent constraints on extensions to the standard model of particle physics. A measurement of the $β$-asymmetry in $^{19}$Ne decay between the initial nuclear spin and the direction of the emitted positron is presented which establishes this decay as the most precisely characterized nuclear mirror and fixes the Fermi-to-Gamow-Teller mixing ratio to $ρ= 1.6014(+21/-28)_{sys}(8)_{stat}$. This is consistent with the previous, most precise measurement, produces a value of the CKM unitarity parameter $V_{ud}$ in agreement with the nuclear mirror, neutron and superallowed $β$-decay data sets, shows no evidence for second class currents, and can be effectively used with neutron decay data to place a limits on exotic tensor couplings.

nucl-ex

$|Δ\mathcal{B}| =2$: A State of the Field, and Looking Forward--A brief status report of theoretical and experimental physics opportunities

The origin of the matter-antimatter asymmetry apparently obligates the laws of physics to include some mechanism of baryon number ($\mathcal{B}$) violation. Searches for interactions violating $\mathcal{B}$ and baryon-minus-lepton number $\mathcal{(B-L)}$ represent a rich and underutilized opportunity. These are complementary to the existing, broad program of searches for $\mathcal{L}$-violating modes such as neutrinoless double $β$-decay which could provide deeper understandings of the plausibility of leptogenesis, or $\mathcal{B}$-violating, $\mathcal{(B-L)}$-conserving processes such as proton decay. In particular, a low-scale, post-sphaleron violation mechanism of $\mathcal{(B-L)}$ could provide a \textit{testable} form of baryogenesis. Though theoretically compelling, searches for such $\mathcal{(B-L)}$-violating processes like $Δ\mathcal{B}=2$ dinucleon decay and $n\rightarrow\bar{n}$ remain relatively underexplored experimentally compared to other rare processes. By taking advantage of upcoming facilities such as the Deep Underground Neutrino Experiment and the European Spallation Source, this gap can be addressed with new intranuclear and free searches for neutron transformations with very high sensitivity, perhaps greater than three orders of magnitude higher than previous experimental searches. This proceedings reports on recent theoretical and experimental advances and sensitivities of next-generation searches for neutron transformations were detailed as part of the Amherst Center for Fundamental Interactions Workshop, "Theoretical Innovations for Future Experiments Regarding Baryon Number Violation," directly coordinated with the Rare Processes and Precision Measurements Frontier.

hep-ph

Precision Beta Decay as a Probe of New Physics

The document presents a summary of discussions at recent workshops at the Amherst Center for Fundamental Interactions at Amherst, MA, and at the European Centre for Theoretical Studies in Nuclear Physics and Related Areas at Trento, Italy, on the potential sensitivity of precision beta-decay experiments towards new physics.

nucl-ex

Increased interference fringe visibility from the post fabrication heat treatment of a perfect crystal silicon neutron interferometer

Construction of silicon neutron interferometers requires a perfect crystal silicon ingot (5 cm to 30 cm long) be machined such that Bragg diffracting "blades" protrude from a common base. Leaving the interferometer blades connected to the same base preserves Bragg plane alignment, but if the interferometer contains crystallographic misalignments of greater than about 10 nrad between the blades, interference fringe visibility begins to suffer. Additionally, the parallelism, thickness, and distance between the blades must be machined to micron tolerances. Traditionally, interferometers do not exhibit usable interference fringe visibility until 30 $μ$m to 60 $μ$m of machining surface damage is chemically etched away. However, if too much material is removed, the uneven etch rates across the interferometer cause the shape of the crystal blades to be outside of the required tolerances. As a result, the ultimate interference fringe visibility varies widely among neutron interferometers that are created under similar conditions. We find that annealing a previously etched interferometer at $800^\circ \mathrm{C}$ dramatically increased interference fringe visibility from 23 % to 90 %. The Bragg plane misalignments were also measured before and after annealing using neutron rocking curve interference peaks, showing that Bragg plane alignment was improved across the interferometer after annealing. This suggests that current interferometers with low fringe visibility may be salvageable and that annealing may become an important step in the fabrication process of future neutron interferometers, leading to less need for chemical etching and larger, more exotic neutron interferometers.

physics.ins-det

Decoupling of a Neutron Interferometer from Temperature Gradients

Neutron interferometry enables precision measurements that are typically operated within elaborate, multi-layered facilities which provide substantial shielding from environmental noise. These facilities are necessary to maintain the coherence requirements in a perfect crystal neutron interferometer which is extremely sensitive to local environmental conditions such as temperature gradients across the interferometer, external vibrations, and acoustic waves. The ease of operation and breadth of applications of perfect crystal neutron interferometry would greatly benefit from a mode of operation which relaxes these stringent isolation requirements. Here, the INDEX Collaboration and National Institute of Standards and Technology demonstrates the functionality of a neutron interferometer in vacuum and characterize the use of a compact vacuum chamber enclosure as a means to isolate the interferometer from spatial temperature gradients and time-dependent temperature fluctuations. The vacuum chamber is found to have no depreciable effect on the performance of the interferometer (contrast) while improving system stability, thereby showing that it is feasible to replace large temperature isolation and control systems with a compact vacuum enclosure for perfect crystal neutron interferometry.

physics.ins-det

V_ud and V_us: CKM 2010 working group I summary

The present status of universality tests of the weak couplings for quarks and leptons is reviewed, with updated information for the muon lifetime and for first-row inputs in the CKM matrix. We discuss the impact of this high-precision SM test in constraining new physics models. We also discuss a precise lepton flavor-violation test from leptonic K decays and recent progress in K-Kbar mixing.

hep-ex