SearcharxivSearch

arXiv subjects

Alberto De Luca

Publications and source records attributed to Alberto De Luca.

6 recordsLinked to original sources

Millennium Pathways for Tractography: 40 grand challenges to shape the future of tractography

In the spirit of the historic Millennium Prize Problems that heralded a new era for mathematics, the newly formed International Society for Tractography (IST) has launched the Millennium Pathways for Tractography, a community-driven roadmap designed to shape the future of the field. Conceived during the inaugural Tract-Anat Retreat, this initiative reflects a collective vision for advancing tractography over the coming decade and beyond. The roadmap consists of 40 grand challenges, developed by international experts and organized into seven categories spanning three overarching themes: neuroanatomy, tractography methods, and clinical applications. By defining shared short-, medium-, and long-term goals, these pathways provide a structured framework to confront fundamental limitations, promote rigorous validation, and accelerate the translation of tractography into a robust tool for neuroscience and medicine. Ultimately, the Millennium Pathways aim to guide and inspire future research and collaboration, ensuring the continued scientific and clinical relevance of tractography well into the future.

physics.med-ph

Federated Learning for Financial Forecasting

This paper studies Federated Learning (FL) for binary classification of volatile financial market trends. Using a shared Long Short-Term Memory (LSTM) classifier, we compare three scenarios: (i) a centralized model trained on the union of all data, (ii) a single-agent model trained on an individual data subset, and (iii) a privacy-preserving FL collaboration in which agents exchange only model updates, never raw data. We then extend the study with additional market features, deliberately introducing not independent and identically distributed data (non-IID) across agents, personalized FL and employing differential privacy. Our numerical experiments show that FL achieves accuracy and generalization on par with the centralized baseline, while significantly outperforming the single-agent model. The results show that collaborative, privacy-preserving learning provides collective tangible value in finance, even under realistic data heterogeneity and personalization requirements.

cs.LG

Generalized Richardson-Lucy (GRL) for analyzing multi-shell diffusion MRI data

Spherical deconvolution is a widely used approach to quantify fiber orientation distribution from diffusion MRI data. The damped Richardson-Lucy (dRL) is developed to perform robust spherical deconvolution on single shell diffusion MRI data. While the dRL algorithm could in theory be directly applied to multi-shell data, it is not optimised to model the signal from multiple tissue types. In this work, we introduce a new framework based on dRL - dubbed Generalized Richardson Lucy (GRL) - that uses multi-shell data in combination with user-chosen tissue models to disentangle partial volume effects and increase the accuracy in FOD estimation. The optimal weighting of multi-shell data in the fit and the robustness to noise and partial volume effects of GRL was studied with synthetic data. Subsequently, we investigated the performances of GRL in comparison to dRL on a high-resolution diffusion MRI dataset from the Human Connectome Project and on an MRI dataset acquired at 3T on a clinical scanner. The feasibility of including intra-voxel incoherent motion (IVIM) effects in the modelling was studied on a third dataset. Results of simulations show that GRL can robustly disentangle different tissue types at SNR above 20 and improves the angular accuracy of the FOD estimation. On real data, GRL provides signal fraction maps that are physiologically plausible and consistent between datasets. When considering IVIM effects, high blood pseudo-diffusion fraction is observed in the medial temporal lobe and in the sagittal sinus. In comparison to dRL, GRL provides sharper FODs and less spurious peaks in presence of partial volume effects and results in a better tract termination at the grey/white matter interface or at the outer cortical surface. In conclusion, GRL offers a new modular and flexible framework to perform spherical deconvolution of multi-shell data.

physics.med-ph

Automated characterization of noise distributions in diffusion MRI data

Knowledge of the noise distribution in diffusion MRI is the centerpiece to quantify uncertainties arising from the acquisition process. Accurate estimation beyond textbook distributions often requires information about the acquisition process, which is usually not available. We introduce two new automated methods using the moments and maximum likelihood equations of the Gamma distribution to estimate all unknown parameters using only the magnitude data. A rejection step is used to make the framework automatic and robust to artifacts. Simulations were created for two diffusion weightings with parallel imaging. Furthermore, MRI data of a water phantom with different combinations of parallel imaging were acquired. Finally, experiments on freely available datasets are used to assess reproducibility when limited information about the acquisition protocol is available. Additionally, we demonstrated the applicability of the proposed methods for a bias correction and denoising task on an in vivo dataset. A generalized version of the bias correction framework for non integer degrees of freedom is also introduced. The proposed framework is compared with three other algorithms with datasets from three vendors, employing different reconstruction methods. Simulations showed that assuming a Rician distribution can lead to misestimation of the noise distribution in parallel imaging. Results showed that signal leakage in multiband can also lead to a misestimation of the noise distribution. Repeated acquisitions of in vivo datasets show that the estimated parameters are stable and have lower variability than compared methods. Results show that the proposed methods reduce the appearance of noise at high b-value. The proposed algorithms herein can estimate both parameters of the noise distribution automatically, are robust to signal leakage artifacts and perform best when used on acquired noise maps.

eess.IV

On the sensitivity of the diffusion MRI signal to brain activity in response to a motor cortex paradigm

Diffusion functional MRI (dfMRI) is a promising technique to map functional activations by acquiring diffusion-weighed spin-echo images. In previous studies, dfMRI showed higher spatial accuracy at activation mapping compared to classic functional MRI approaches. However, it remains unclear whether dfMRI measures result from changes in the intra-/extracellular environment, perfusion and/or T2 values. We designed an acquisition/quantification scheme to disentangle such effects in the motor cortex during a finger tapping paradigm. dfMRI was acquired at specific diffusion weightings to selectively suppress perfusion and free-water diffusion, then times series of the apparent diffusion coefficient (ADC-fMRI) and of the perfusion signal fraction (IVIM-fMRI) were derived. ADC-fMRI provided ADC estimates sensitive to changes in perfusion and free-water volume, but not to T2/T2* values. With IVIM-fMRI we isolated the perfusion contribution to ADC, while suppressing T2 effects. Compared to conventional gradient-echo BOLD fMRI, activation maps obtained with dfMRI and ADC-fMRI had smaller clusters, and the spatial overlap between the three techniques was below 50%. Increases of perfusion fractions were observed during task in both dfMRI and ADC-fMRI activations. Perfusion effects were more prominent with ADC-fMRI than with dfMRI but were significant in less than 25% of activation ROIs. Taken together, our results suggest that the sensitivity to task of dfMRI derives from a decrease of hindered diffusion and an increase of the pseudo-diffusion signal fraction, leading to different, more confined spatial activation patterns compared to classic functional MRI.

physics.med-ph

Automatic, fast and robust characterization of noise distributions for diffusion MRI

Knowledge of the noise distribution in magnitude diffusion MRI images is the centerpiece to quantify uncertainties arising from the acquisition process. The use of parallel imaging methods, the number of receiver coils and imaging filters applied by the scanner, amongst other factors, dictate the resulting signal distribution. Accurate estimation beyond textbook Rician or noncentral chi distributions often requires information about the acquisition process (e.g. coils sensitivity maps or reconstruction coefficients), which is not usually available. We introduce a new method where a change of variable naturally gives rise to a particular form of the gamma distribution for background signals. The first moments and maximum likelihood estimators of this gamma distribution explicitly depend on the number of coils, making it possible to estimate all unknown parameters using only the magnitude data. A rejection step is used to make the method automatic and robust to artifacts. Experiments on synthetic datasets show that the proposed method can reliably estimate both the degrees of freedom and the standard deviation. The worst case errors range from below 2% (spatially uniform noise) to approximately 10% (spatially variable noise). Repeated acquisitions of in vivo datasets show that the estimated parameters are stable and have lower variances than compared methods.

cs.CV