SearcharxivSearch

arXiv subjects

Alberto Mittone

Publications and source records attributed to Alberto Mittone.

2 recordsLinked to original sources

Tomo-center: an AI-based rotation-axis center finder for synchrotron micro- and nano-tomography

Accurate determination of the rotation-axis position is a prerequisite for artifact-free reconstruction in parallel-beam synchrotron micro-tomography. Traditional approaches such as Vo's method rely on sinogram features that can fail for low-contrast or weakly absorbing specimens. We present a learning-based method that treats center selection as a binary classification problem, using a DINOv2-pretrained vision transformer aggregated with attention-based multiple-instance learning, fine-tuned end-to-end on tomographic images. At inference time, the proposed algorithm was applied to a stack of tomograms reconstructed at a sweep of candidate centers to select the optimal center for reconstruction. We tested the estimation accuracy of the proposed method on two independent data sources and consistently achieved a mean absolute error of below 1 pixel. We also tested the method robustness to sparse or noisy acquisitions with the same datasets and demonstrated consistent performance when the number of projections was reduced by a factor of up to 10 or the blank scan factor of the underlying Poisson's noise was increased to 10. We also illustrated the interpretability of the proposed method by mapping out the relative contributions of continuous spatial features to the overall classification task. This method, delivered as tomo-center, an open-source command-line tool, has been integrated into several tomography software packages to assist experiments during the routine beamline operations.

eess.IV

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as the whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared to the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, we present a laminography pipeline for imaging large samples (> 1 cm) at micrometer resolution. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source (APS). Additionally, we present sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets. The applicability of the whole laminography pipeline was demonstrated with imaging 4 sequential slabs throughout the entire mouse brain sample stained with osmium, in total generating approximately 12TB of raw data for reconstruction.

physics.comp-ph