Searcharxiv⌕ Search

arXiv subjects

Alessandro Di Marco

Publications and source records attributed to Alessandro Di Marco.

At least 127 records · Page 7Linked to original sources

Observations of 4U 1626-67 with the Imaging X-ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the 2-8 keV band from the pulsar in the ultracompact low mass X-ray binary 4U1626-67 using data from the Imaging X-ray Polarimetry Explorer (IXPE). The 7.66 s pulsations were clearly detected throughout the IXPE observations as well as in the NICER soft X-ray observations, which we use as the basis for our timing analysis and to constrain the spectral shape over 0.4-10 keV energy band. Chandra HETGS high-resolution X-ray spectra were also obtained near the times of the IXPE observations for firm spectral modeling. We find an upper limit on the pulse-averaged linear polarization of <4% (at 95% confidence). Similarly, there was no significant detection of polarized flux in pulse phase intervals when subdividing the bandpass by energy. However, spectropolarimetric modeling over the full bandpass in pulse phase intervals provide a marginal detection of polarization of the power-law spectral component at the 4.8 +/- 2.3% level (90% confidence). We discuss the implications concerning the accretion geometry onto the pulsar, favoring two-component models of the pulsed emission.

astro-ph.HE↗

The X-ray Polarization View of Mrk~421 in an Average Flux State as Observed by the Imaging X-ray Polarimetry Explorer

Particle acceleration mechanisms in supermassive black hole jets, such as shock acceleration, magnetic reconnection, and turbulence, are expected to have observable signatures in the multi-wavelength polarization properties of blazars. The recent launch of the Imaging X-ray Polarimetry Explorer (IXPE) enables us, for the first time, to use polarization in the X-ray band (2-8 keV) to probe the properties of the jet synchrotron emission in high-frequency-peaked BL Lac objects (HSPs). We report the discovery of X-ray linear polarization (degree $Π_{\rm x}=15\pm$2\% and electric-vector position angle $Ψ_{\rm x}=35^\circ\pm4^\circ$) from the jet of the HSP Mrk~421 in an average X-ray flux state. At the same time, the degree of polarization at optical, infrared, and millimeter wavelengths was found to be lower by at least a factor of 3. During the IXPE pointing, the X-ray flux of the source increased by a factor of 2.2, while the polarization behavior was consistent with no variability. The higher level of $Π_{\rm x}$ compared to longer wavelengths, and the absence of significant polarization variability, suggest a shock as the most likely X-ray emission site in the jet of Mrk 421 during the observation. The multiwavelength polarization properties are consistent with an energy-stratified electron population, where the particles emitting at longer wavelengths are located farther from the acceleration site, where they experience a more disordered magnetic field.

astro-ph.HE↗

The X-ray polarimetry view of the accreting pulsar Cen X-3

Cen X-3 is the first X-ray pulsar discovered 50 years ago. Radiation from such objects is expected to be highly polarized due to birefringence of plasma and vacuum associated with propagation of photons in presence of the strong magnetic field. Here we present results of the observations of Cen X-3 performed with the Imaging X-ray Polarimetry Explorer. The source exhibited significant flux variability and was observed in two states different by a factor of ~20 in flux. In the low-luminosity state no significant polarization was found either in pulse phase-averaged (with the 3$σ$ upper limit of 12%) or phase-resolved data (the 3$σ$ upper limits are 20-30%). In the bright state the polarization degree of 5.8$\pm$0.3% and polarization angle of $49.6°\pm1.5°$ with significance of about 20$σ$ was measured from the spectro-polarimetric analysis of the phase-averaged data. The phase-resolved analysis showed a significant anti-correlation between the flux and the polarization degree as well as strong variations of the polarization angle. The fit with the rotating vector model indicates a position angle of the pulsar spin axis of about 49$°$ and a magnetic obliquity of 17$°$. The detected relatively low polarization can be explained if the upper layers of the neutron star surface are overheated by the accreted matter and the conversion of the polarization modes occurs within the transition region between the upper hot layer and a cooler underlying atmosphere. A fraction of polarization signal can also be produced by reflection of radiation from the neutron star surface and the accretion curtain.

astro-ph.HE↗

X-ray polarization detection of Cassiopeia A with IXPE

We report on a $\sim 5σ$ detection of polarized 3-6 keV X-ray emission from the supernova remnant Cassiopeia A with the Imaging X-ray Polarimetry Explorer (IXPE). The overall polarization degree of $1.8 \pm 0.3$% is detected by summing over a large region, assuming circular symmetry for the polarization vectors. The measurements imply an average polarization degree for the synchrotron component of $\sim 2.5$%, and close to 5% for the X-ray synchrotron-domimated forward-shock region. These numbers are based on an assessment of the thermal and non-thermal radiation contributions, for which we used a detailed spatial-spectral model based on Chandra X-ray data. A pixel-by-pixel search for polarization provides a few tentative detections from discrete regions at the $\sim 3σ$ confidence level. Given the number of pixels, the significance is {insufficient} to claim a detection for individual pixels, but implies considerable turbulence on scales smaller than the angular resolution. Cas A's X-ray continuum emission is dominated by synchrotron radiation from regions within $\lesssim 10^{17}$ cm of the forward- and reverse shocks. We find that i) the measured polarization angle corresponds to a radially-oriented magnetic field, similar to what has been inferred from radio observations; ii) the X-ray polarization degree is lower than in the radio band ($\sim 5$%). Since shock compression should impose a tangential magnetic field structure, the IXPE results imply that magnetic-fields are reoriented within $\sim 10^{17}$cm of the shock. If the magnetic-field alignment is due to locally enhanced acceleration near quasi-parallel shocks, the preferred X-ray polarization angle suggests a size of $3\times 10^{16}$ cm for cells with radial magnetic fields.

astro-ph.HE↗

CUSP: a two cubesats constellation for Space Weather and solar flares X-ray polarimetry

The CUbesat Solar Polarimeter (CUSP) project aims to develop a constellation of two CubeSats orbiting the Earth to measure the linear polarisation of solar flares in the hard X-ray band by means of a Compton scattering polarimeter on board of each satellite. CUSP will allow to study the magnetic reconnection and particle acceleration in the flaring magnetic structures. CUSP is a project approved for a Phase A study by the Italian Space Agency in the framework of the Alcor program aimed to develop CubeSat technologies and missions.

astro-ph.SR↗

Simultaneous space and phase resolved X-ray polarimetry of the Crab Pulsar and Nebula

The Crab pulsar and its nebula are among the most studied astrophysical systems, and constitute one of the most promising environments where high energy processes and particle acceleration can be investigated. They are the only objects for which previous X-ray polarisation has been reported. We present here the first Imaging X-ray Polarimetry Explorer (IXPE) observation of the Crab pulsar and nebula. The total pulsar pulsed emission in the [2-8] keV energy range is unpolarised. Significant polarisation up to 15% is detected only in the core of the main peak. The nebula has a total space integrated polarised degree of 20% and polarisation angle of 145deg. The polarised maps show a large variation in the local polarisation, and regions with polarised degree up to 45-50%. The polarisation pattern suggests a predominantly toroidal magnetic field.

astro-ph.HE↗

Limits on X-ray Polarization at the Core of Centaurus A as Observed with the Imaging X-ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the $2-8 \thinspace \mathrm{keV}$ band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at $99 \%$ percent confidence (MDP$_{99}$) of $6.5 \%$ using a weighted, spectral model-independent calculation in the $2-8 \thinspace \mathrm{keV}$ band. The polarization angle $ψ$ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy ($0.3-400 \thinspace \mathrm{keV}$) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption ($N_H \sim 10^{23} \thinspace \mathrm{cm}^{-2}$) and a Fe K$α$ emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below $2 \thinspace \mathrm{keV}$. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe K$α$ emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

astro-ph.HE↗

Calibration of the IXPE focal plane X-ray polarimeters to polarized radiation

IXPE (Imaging X-ray Polarimetry Explorer) is a NASA Small Explorer mission -- in partnership with the Italian Space Agency (ASI) -- dedicated to X-ray polarimetry in the 2--8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector (GPD), a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units (DUs) at INAF-IAPS, in Italy, where a dedicated facility was set-up at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

astro-ph.IM↗

Polarized x-rays from a magnetar

We report on the first detection of linearly polarized x-ray emission from an ultra-magnetized neutron star with the Imaging X-ray Polarimetry Explorer (IXPE). The IXPE 35 observations of the anomalous x-ray pulsar 4U 0142+61 reveal a linear polarization degree of $(12\pm 1)\%$ throughout the IXPE 2--8 keV band. We detect a substantial variation of the polarization with energy: the degree is $(14\pm 1)\%$ at 2--4 keV and $(41\pm 7)\%$ at 5.5--8 keV, while it drops below the instrumental sensitivity around 4--5 keV, where the polarization angle swings by $\sim 90^\circ$. The IXPE observations give us completely new information about the properties of the neutron star surface and magnetosphere and lend further support to the presence of the quantum mechanical effect of vacuum birefringence.

astro-ph.HE↗

A weighted analysis to improve the X-ray polarization sensitivity of IXPE

IXPE is a Small Explorer mission that was launched at the end of 2021 to measure the polarization of X-ray emission from tens of astronomical sources. Its focal plane detectors are based on the Gas Pixel Detector, which measures the polarization by imaging photoelectron tracks in a gas mixture and reconstructing their initial directions. The quality of the single track, and then the capability of correctly determining the original direction of the photoelectron, depends on many factors, e.g., whether the photoelectron is emitted at low or high inclination with respect to the collection plane or the occurrence of a large Coulomb scattering close to the generation point. The reconstruction algorithm used by IXPE to obtain the photoelectron emission direction, also calculates several properties of the shape of the tracks which characterize the process. In this paper we compare several such properties and identify the best one to weight each track on the basis of the reconstruction accuracy. We demonstrate that significant improvement in sensitivity can be achieved with this approach and for this reason it will be the baseline for IXPE data analysis.

astro-ph.IM↗

The Imaging X-Ray Polarimetry Explorer (IXPE): Pre-Launch

Scheduled to launch in late 2021, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation - imaging X-ray polarimetry. The observatory features 3 identical telescopes each consisting of a mirror module assembly with a polarization-sensitive imaging X-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a 3-axis-stabilized spacecraft which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of X-ray sources, with follow-on observations of selected targets.

astro-ph.IM↗

An algorithm to calibrate and correct the response to unpolarized radiation of the X-ray polarimeter on board IXPE

The Gas Pixel Detector is an X-ray polarimeter to fly on-board IXPE and other missions. To correctly measure the source polarization, the response of IXPE's GPDs to unpolarized radiation has to be calibrated and corrected. In this paper we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and non-monochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

astro-ph.IM↗

The IXPE Instrument Calibration Equipment

The Imaging X-ray Polarimetry Explorer is a mission dedicated to the measurement of X-ray polarization from tens of astrophysical sources belonging to different classes. Expected to be launched at the end of 2021, the payload comprises three mirrors and three focal plane imaging polarimeters, the latter being designed and built in Italy. While calibration is always an essential phase in the development of high-energy space missions, for IXPE it has been particularly extensive both to calibrate the response to polarization, which is peculiar to IXPE, and to achieve a statistical uncertainty below the expected sensitivity. In this paper we present the calibration equipment that was designed and built at INAF-IAPS in Rome, Italy, for the calibration of the polarization-sensitive focal plane detectors on-board IXPE. Equipment includes calibration sources, both polarized and unpolarized, stages to align and move the beam, test detectors and their mechanical assembly. While all these equipments were designed to fit the specific needs of the IXPE Instrument calibration, their versatility could also be used in the future for other projects.

astro-ph.IM↗

Exploring the accretion-ejection geometry of GRS 1915+105 in the obscured state with future X-ray spectro-polarimetry

GRS 1915+105 has been in a bright flux state for more than 2 decades, but in 2018 a significant drop in flux was observed, partly due to changes in the central engine along with increased X-ray absorption. The aim of this work is to explore how X-ray spectro-polarimetry can be used to derive the basic geometrical properties of the absorbing and reflecting matter. In particular, the expected polarisation of the radiation reflected off the disc and the putative outflow is calculated. We use \textit{NuSTAR} data collected after the flux drop to derive the parameters of the system from hard X-ray spectroscopy. The spectroscopic parameters are then used to derive the expected polarimetric signal, using results from a MonteCarlo radiative transfer code both in the case of neutral and fully ionised matter. From the spectral analysis, we find that the continuum emission becomes softer with increasing flux, and that in all flux levels the obscuring matter is highly ionised. This analysis, on the other hand, confirms that spectroscopy alone is unable to put constraints on the geometry of the reflectors. Simulations show that X-ray polarimetric observations, like those that will be provided soon by the Imaging X-ray Polarimetry Explorer (IXPE), will help to determine the geometrical parameters which are left unconstrained by the spectroscopic analysis.

astro-ph.HE↗

The Instrument of the Imaging X-ray Polarimetry Explorer

While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s. The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument. IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

astro-ph.IM↗

Variable Inflaton Equation of State and Reheating

We explore the consequences of a time-dependent inflaton Equation-of-State (EoS) parameter in the context of the post-inflationary perturbative Boltzmann reheating. In particular, we numerically solve the perturbative coupled system of Boltzmann equations involving the inflaton energy density, the radiation energy density and the related entropy density and temperature of the produced particle thermal bath. We exploit reasonable Ansätze for the EoS and discuss the robustness of the Boltzmann system. We also comment on the possible microscopic origin related to a time dependent inflaton potential, discussing the consequences on a preheating stage and the related (primordial) gravitational waves.

gr-qc↗

A Study of background for IXPE

Focal plane X-ray polarimetry is intended for relatively bright sources with a negligible impact of background. However this might not be always possible for IXPE (Imaging X-ray Polarimetry Explorer) when observing faint extended sources like supernova remnants. We present for the first time the expected background of IXPE by Monte Carlo simulation and its impact on real observations of point and extended X-ray sources. The simulation of background has been performed by Monte Carlo based on GEANT4 framework. The spacecraft and the detector units have been modeled, and the expected background components in IXPE orbital environment have been evaluated. We studied different background rejection techniques based on the analysis of the tracks collected by the Gas Pixel Detectors on board IXPE. The estimated background is about 2.9 times larger than the requirement, yet it is still negligible when observing point like sources. Albeit small, the impact on supernova remnants indicates the need for a background subtraction for the observation of the extended sources.

astro-ph.IM↗

In-flight calibration system of Imaging X-ray Polarimetry Explorer

The NASA/ASI Imaging X-ray Polarimetry Explorer, which will be launched in 2021, will be the first instrument to perform spatially resolved X-ray polarimetry on several astronomical sources in the 2-8 keV energy band. These measurements are made possible owing to the use of a gas pixel detector (GPD) at the focus of three X-ray telescopes. The GPD allows simultaneous measurements of the interaction point, energy, arrival time, and polarization angle of detected X-ray photons. The increase in sensitivity, achieved 40 years ago, for imaging and spectroscopy with the Einstein satellite will thus be extended to X-ray polarimetry for the first time. The characteristics of gas multiplication detectors are subject to changes over time. Because the GPD is a novel instrument, it is particularly important to verify its performance and stability during its mission lifetime. For this purpose, the spacecraft hosts a filter and calibration set (FCS), which includes both polarized and unpolarized calibration sources for performing in-flight calibration of the instruments. In this study, we present the design of the flight models of the FCS and the first measurements obtained using silicon drift detectors and CCD cameras, as well as those obtained in thermal vacuum with the flight units of the GPD. We show that the calibration sources successfully assess and verify the functionality of the GPD and validate its scientific results in orbit; this improves our knowledge of the behavior of these detectors in X-ray polarimetry.

astro-ph.IM↗