SearcharxivSearch

arXiv subjects

Alessandro Razeto

Publications and source records attributed to Alessandro Razeto.

8 recordsLinked to original sources

Can $\pi$ generate itself? A Monte Carlo analysis of 314 trillion digits

At the end of 2025, a record computation of $\pi$ reached 314 trillion decimal digits, providing the largest numerical dataset ever generated for this constant. We exploit this unprecedented dataset to investigate whether the digits of $\pi$ themselves can serve as a source of pseudorandom numbers for estimating $\pi$ through the simplest Monte Carlo method. Our results go beyond the normality hypothesis by providing empirical evidence of a high degree of statistical randomness in the available digits, although not of digit independence, which cannot hold for a deterministic sequence. By optimizing the mapping of the digit sequence into Monte Carlo samples, we obtain the highest precision allowed by the dataset. As predicted, the method successfully reproduces the first sequence of decimal digits, demonstrating that the largest available dataset of $\pi$ digits can be used to recover $ \pi \approx 3.141593 $ through Monte Carlo simulation.

math.GM

Analytical model for the photomultiplier single photoelectron response including the electron back-scattering contribution

Many models exist to describe the single photoelectron response of single photon counting photomultipliers. Generally to describe the spectral region between the fully amplified primary photoelectron peak and the electronics pedestal an ad hoc function is used (often an exponentially modified gaussian) attributing this region to `noise'. In this paper, following the physical description of back-scattered primary photoelectrons at the first dynode described in the "The Photomultiplier Handbook" by A. G. Wright published by Oxford University Press, we derive an analytical function describing these partially amplified primary photoelectron at the first dynode. This function depends only on intrinsic parameters of the photomultiplier such as the gain at the first dynode and the intrinsic resolution of the dynode chain following the first. Furthermore, analytical descriptions of the fully amplified peak and very low charge signals are derived. The model has been successfully validated with data from two different photomultipliers acquired with a low-noise amplifier.

physics.ins-det

Challenges for dark matter direct search with SiPMs

Liquid xenon and liquid argon detectors are leading the direct dark matter search and are expected to be the candidate technology for the forthcoming generation of ultra-sensitive large-mass detectors. At present, the scintillation light detection in those experiments is based on ultra-pure low-noise photo-multipliers. To overcome the issues in terms of the extreme radio-purity, costs, and technological feasibility of the future dark matter experiments, the novel SiPM-based photo-detector modules look promising candidates, capable of replacing the present light detection technology. However, the intrinsic features of SiPMs may limit the present expectations. In particular, interfering phenomena, especially related to the optical correlated noise, can degrade the energy and pulse shape resolutions. As a consequence, the projected sensitivity of the future detectors has to be reconsidered accordingly.

hep-ex

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of $14.7^{+1.1}_{-2.4}$% and $17.2^{+1.6}_{-3.0}$% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

physics.ins-det

Development of a novel single-channel, 24~cm$^2$, SiPM-based, cryogenic photodetector

We report on the realization of a novel SiPM-based, cryogenic photosensor with an active area of 24 cm$^2$ that operates as a single-channel analog detector. The device is capable of single photon counting with a signal to noise ratio better than 13, a dark rate lower than $10^{-2}$ cps/mm$^2$ and an overall photon detection efficiency significantly larger than traditional photomultiplier tubes. This development makes SiPM-based photosensors strong candidates for the next generation of dark matter and neutrino detectors, which will require multiple square meters of photosensitive area, low levels of intrinsic radioactivity and a limited number of detector channels.

physics.ins-det

Development of a very low-noise cryogenic pre-amplifier for large-area SiPM devices

Silicon Photomultipliers (SiPMs) are an excellent candidate for the development of large-area light sensors. Large SiPM-based detectors require low-noise pre-amplifiers to maximize the signal coupling between the sensor and the readout electronics. This article reports on the development of a low-noise transimpedance amplifier sensitive to single-photon signals at cryogenic temperature. The amplifier is used to readout a 1 cm$^{2}$ SiPM with a signal to noise ratio in excess of 40.

physics.ins-det

Cryogenic Characterization of FBK HD Near-UV Sensitive SiPMs

We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and correlated noise of the \SiPMs\ between 40 and 300~K. Moreover, an analysis program and data acquisition system were developed to allow the precise characterization of these parameters, some of which can vary up to 7 orders of magnitude between room temperature and 40~K. We demonstrate that it is possible to operate the \FBK\ near-ultraviolet high density \SiPMs\ at temperatures lower than 100~K with a dark rate below 0.01 cps/mm$^2$ and total correlated noise probability below 35\% at an over-voltage of 6~V. These results are relevant for the development of future cryogenic particle detectors using \SiPMs\ as photosensors.

physics.ins-det

Feasibility study of SiGHT: a novel ultra low background photosensor for low temperature operation

Rare event search experiments, such as those searching for dark matter and observations of neutrinoless double beta decay, require ultra low levels of radioactive background for unmistakable identification. In order to reduce the radioactive backgrounds of detectors used in these types of event searches, low background photosensors are required, as the physical size of these detectors become increasing larger, and hence the number of such photosensors used also increases rapidly. Considering that most dark matter and neutrinoless double beta decay experiments are turning towards using noble liquids as the target choice, liquid xenon and liquid argon for instance, photosensors that can work well at cryogenic temperatures are required, 165 K and 87 K for liquid xenon and liquid argon, respectively. The Silicon Geiger Hybrid Tube (SiGHT) is a novel photosensor designed specifically for use in ultra low background experiments operating at cryogenic temperatures. It is based on the proven photocathode plus silicon photomultiplier (SiPM) hybrid technology and consists of very few other, but also ultra radio-pure, materials like fused silica and silicon for the SiPM. The introduction of the SiGHT concept, as well as a feasibility study for its production, is reported in this paper.

physics.ins-det