Towards reliable electrical measurements of superconducting devices inside a transmission electron microscope

Correlating structure with electronic functionality is central to the engineering of quantum materials and devices whose properties depend sensitively on disorder. Transmission electron microscopy (TEM) offers high spatial resolution together with access to structural, electronic, and magnetic degrees of freedom. However, operando electrical transport measurements on functional quantum devices remain rare, particularly at liquid helium temperature. Here, we demonstrate electrical transport measurements of niobium nitride (NbN) devices inside a TEM using a continuous-flow liquid-helium-cooled sample holder. By optimizing a thermal radiation shield to limit radiation from the nearby pole pieces of the objective lens, we achieve an estimated base sample temperature of 8-9 K, as inferred from the superconducting transition temperatures of our devices. We find that both electron beam illumination and objective lens excitation perturb the superconducting state. In addition, we evaluate the imaging capabilities and stability of the sample holder at low temperature by imaging the magnetic domain structure of the van der Waals ferromagnet CrBr$_3$. Finally, we perform calculations that underscore the importance of cryo-shielding for minimizing thermal radiation onto the device. This capability enables correlative low-temperature TEM studies, in which structural, spectroscopic, and electrical transport data can be obtained from the same device, thereby providing a platform for probing the microscopic origins of quantum phenomena.

cond-mat.supr-con

Calibrating coordinate system alignment in a scanning transmission electron microscope using a digital twin

In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured that the scan coordinate system of the beam is correctly calibrated relative to the detector coordinate system. Various simplified and approximate models are used implicitly and explicitly for understanding and analyzing the recorded data, requiring translation between the physical reality of the instrument and the abstractions used in data interpretation. Here, we introduce a calibration method where interactive live data processing in combination with a digital twin is used to match a set of models and their parameters with the action of a real-world instrument.

physics.ins-det

Live Iterative Ptychography

We demonstrate live-updating ptychographic reconstruction with ePIE, an iterative ptychography method, during ongoing data acquisition. The reconstruction starts with a small subset of the total data, and as the acquisition proceeds the data used for reconstruction is extended. This creates a live-updating view of object and illumination that allows monitoring the ongoing experiment and adjusting parameters with quick turn-around. This is particularly advantageous for long-running acquisitions. We show that such a gradual reconstruction yields interpretable results already with a small subset of the data. We show simulated live processing with various scan patterns, parallelized reconstruction, and real-world live processing at the hard X-ray ptychographic nanoanalytical microscope PtyNAMi at the PETRA III beamline.

physics.optics

Wigner Distribution Deconvolution Adaptation for Live Ptychography Reconstruction

We propose a modification of Wigner Distribution Deconvolution (WDD) to support live processing ptychography. Live processing allows to reconstruct and display the specimen transfer function gradually while diffraction patterns are acquired. For this purpose we reformulate WDD and apply a dimensionality reduction technique that reduces memory consumption and increases processing speed. We show numerically that this approach maintains the reconstruction quality of specimen transfer functions as well as reduces computational complexity during acquisition processes. Although we only present the reconstruction for Scanning Transmission Electron Microscopy (STEM) datasets, in general, the live processing algorithm we present in this paper can be applied to real-time ptychographic reconstruction for different fields of application.

cs.IT

Inverse Multislice Ptychography by Layer-wise Optimisation and Sparse Matrix Decomposition

We propose algorithms based on an optimisation method for inverse multislice ptychography in, e.g. electron microscopy. The multislice method is widely used to model the interaction between relativistic electrons and thick specimens. Since only the intensity of diffraction patterns can be recorded, the challenge in applying inverse multislice ptychography is to uniquely reconstruct the electrostatic potential in each slice up to some ambiguities. In this conceptual study, we show that a unique separation of atomic layers for simulated data is possible when considering a low acceleration voltage. We also introduce an adaptation for estimating the illuminating probe. For the sake of practical application, we finally present slice reconstructions using experimental 4D scanning transmission electron microscopy (STEM) data.

cs.IT

Live processing of momentum-resolved STEM data for first moment imaging and ptychography

A reformulated implementation of single-sideband ptychography enables analysis and display of live detector data streams in 4D scanning transmission electron microscopy (STEM) using the LiberTEM open-source platform. This is combined with live first moment and further virtual STEM detector analysis. Processing of both real experimental and simulated data shows the characteristics of this method when data is processed progressively, as opposed to the usual offline processing of a complete dataset. In particular, the single side band method is compared to other techniques such as the enhanced ptychographic engine in order to ascertain its capability for structural imaging at increased specimen thickness. Qualitatively interpretable live results are obtained also if the sample is moved, or magnification is changed during the analysis. This allows live optimization of instrument as well as specimen parameters during the analysis. The methodology is especially expected to improve contrast- and dose-efficient in-situ imaging of weakly scattering specimens, where fast live feedback during the experiment is required.

physics.data-an

Next-Generation Information Technology Systems for Fast Detectors in Electron Microscop

The Gatan K2 IS direct electron detector (Gatan Inc., 2018), which was introduced in 2014, marked a watershed moment in the development of cameras for transmission electron microscopy (TEM) (Pan & Czarnik, 2016). Its pixel frequency, i.e. the number of data points (pixels) recorded per second, was two orders of magnitude higher than the fastest cameras available only five years before. Starting from 2009, the data rate of TEM cameras has outpaced the development of network, mass storage and memory bandwidth by almost two orders of magnitude. Consequently, solutions based on personal computers (PCs) that were adequate until then are no longer able to handle the resulting data rates. Instead, tailored high-performance setups are necessary. Similar developments have occurred for advanced X-ray sources such as the European XFEL, requiring special information technology (IT) systems for data handling (Sauter, Hattne, Grosse-Kunstleve, & Echols, 2013) (Fangohr, et al., 2018). Information and detector technology are currently under rapid development and involve disruptive technological innovations. This chapter briefly reviews the technological developments of the past 20 years, presents a snapshot of the current situation at the beginning of 2019 with many practical considerations, and looks forward to future developments.

cs.DC