Development of a Proton Therapy Research Beamline with FLASH and Minibeam Capabilities at the 18 MeV Bern Medical Cyclotron

Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain. Progress requires accessible proton research platforms with flexible temporal and spatial dose delivery. We report on the adaptation of the Beam Transfer Line (BTL) of the Bern Medical Cyclotron (BMC) for radiobiology research with FLASH and proton minibeam capabilities. The BMC is optimized for the production of radionuclides for medical imaging, and is able to extract currents up to 150 $ \mathrm{\mu A}$. The 18 MeV proton beam was passively shaped using collimators, scattering foils, and extended drift space to generate irradiation fields. A dosimetric framework was implemented using an in-beam ionization chamber and radiochromic film with LET-dependent corrections. Beam uniformity and SFRT profiles with various grid spacings were evaluated at realistic target distances. The developed beamline enables stable delivery under controlled conditions in both conventional and FLASH regimes, spanning dose rates from 0.01 to 100 Gy/s. Dose uniformity within a 20 mm radius was below 8\%. Film measurements confirmed the need for LET-dependent corrections and indicated that quantitative dosimetry in in-vitro setups is achievable with appropriate LET corrections. The low proton energy (15.54(12) MeV extracted into air, 8.14(28) MeV delivered to cells in flask) facilitates compact SFRT implementation with well-resolved minibeams. The adapted BMC provides a flexible and accessible platform for systematic pre-clinical proton radiobiology studies under varied dose-rate and spatial delivery conditions. This supports optimization of emerging modalities such as proton FLASH and SFRT and helps bridge accelerator technology and radiobiology.

physics.med-ph

Non-Destructive Beam Monitoring via Secondary Radiation Detection with Ce-Doped Silica Fibers

Non-destructive beam diagnostics are essential for low-energy medical cyclotrons, where even thin interceptive devices can severely degrade beam quality. We investigate an external fiber monitor (EFM) based on Ce-doped silica scintillating fibers that detects secondary radiation generated at existing beamline components of the 18 MeV Bern Medical Cyclotron beam transfer line (BTL). Three use cases were studied: (i) beam intensity monitoring around an electrically isolated, water-cooled beam dump; (ii) beam-loss monitoring around a 10 mm collimator under varying the beam focusing; and (iii) by steering a 6.5 mm $\times$ 6.5 mm beam spot on a beam dump. For case (i), the summed EFM signal exhibits a linear dependence on the current on target over nearly three orders of magnitude. In case (ii), a normalized EFM-based beam-loss proxy scales monotonically with an electrical loss proxy across several focusing settings. Furthermore, opposing-fiber signal ratios provide decoupled, monotonic sensitivity to horizontal and vertical beam displacements.

physics.ins-det

Beam Energy Measurement using a Bayesian Approach with the Stacked Foil Method

We present a practical method to measure the energy of proton beams at a medical cyclotron using the stacked foil technique in combination with a Bayesian inference method. By measuring the $^{48}$V activity induced in a stack of irradiated titanium foils, the proton energy can be inferred without relying on direct current or charge measurements, making the method suitable even for low-vacuum environments or air-exposed setups. This technique is further extended to configurations where the beam energy is degraded to levels around 8 MeV. A Bayesian fit of the measured activity profile allows not only for a robust energy estimation but also for a consistent treatment of uncertainties and nuisance parameters. Monte Carlo simulations are employed to validate the underlying assumptions, including the impact of energy dispersion or cross-section uncertainties. Our results demonstrate that this method provides accurate beam energy measurements across several typical experimental setups used at the Bern Medical Cyclotron. Additionally, we evaluate the sensitivity of the method to the choice of nuclear cross-section data and assess how the number of foils in the stack affects the uncertainty in the inferred beam energy.

physics.acc-ph

Amorphous silicon detectors for proton beam monitoring in FLASH radiotherapy

Ultra-high dose rate radiation therapy (FLASH) based on proton irradiation is of major interest for cancer treatments but creates new challenges for dose monitoring. Amorphous hydrogenated silicon is known to be one of the most radiation-hard semiconductors. In this study, detectors based on this material are investigated at proton dose rates similar to or exceeding those required for FLASH therapy. Tested detectors comprise two different types of contacts, two different thicknesses deposited either on glass or on polyimide substrates. All detectors exhibit excellent linear behaviour as a function of dose rate up to a value of 20 kGy/s. Linearity is achieved independently of the depletion condition of the device and remarkably in passive (unbiased) conditions. The degradation of the performance as a function of the dose rate and its recovery are also discussed.

hep-ex

New Limit on Axion-Like Dark Matter using Cold Neutrons

We report on a search for dark matter axion-like particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon-coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from 23 $\mu$Hz to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows to constrain the coupling of ALPs to gluons in the mass range from $10^{-19}$ to $4 \times 10^{-12}$ eV. The best limit of $C_G$/$f_a m_a = 2.7 \times 10^{13}$ GeV$^{-2}$ (95\% C.L.) is reached in the mass range from $2 \times 10^{-17}$ to $2 \times 10^{-14}$ eV.

hep-ex