Searcharxiv⌕ Search

arXiv subjects

Alexander Huck

Publications and source records attributed to Alexander Huck.

At least 37 records · Page 2Linked to original sources

High speed microcircuit and synthetic biosignal widefield imaging using nitrogen vacancies in diamond

The ability to measure the passage of electrical current with high spatial and temporal resolution is vital for applications ranging from inspection of microscopic electronic circuits to biosensing. Being able to image such signals passively and remotely at the same time is of high importance, to measure without invasive disruption of the system under study or the signal itself. A new approach to achieve this utilises point defects in solid state materials, in particular nitrogen vacancy (NV) centres in diamond. Acting as a high density array of independent sensors, addressable opto-electronically and highly sensitive to factors including temperature and magnetic field, these are ideally suited to microscopic widefield imaging. In this work we demonstrate such imaging of signals from a microscopic lithographically patterned circuit at the micrometer scale. Using a new type of lock-in amplifier camera, we demonstrate sub-millisecond (up to 3500 frames-per-second) spatially resolved recovery of AC and pulsed electrical current signals, without aliasing or undersampling. Finally, we demonstrate as a proof of principle the recovery of synthetic signals replicating the exact form of signals in a biological neural network: the hippocampus of a mouse.

quant-ph↗

Optimal control of a nitrogen-vacancy spin ensemble in diamond for sensing in the pulsed domain

Defects in solid state materials provide an ideal, robust platform for quantum sensing. To deliver maximum sensitivity, a large ensemble of non-interacting defects hosting coherent quantum states are required. Control of such an ensemble is challenging due to the spatial variation in both the defect energy levels and in any control field across a macroscopic sample. In this work we experimentally demonstrate that we can overcome these challenges using Floquet theory and optimal control optimization methods to efficiently and coherently control a large defect ensemble, suitable for sensing. We apply our methods experimentally to a spin ensemble of up to 4 $\times$ 10$^9$ nitrogen vacancy (NV) centers in diamond. By considering the physics of the system and explicitly including the hyperfine interaction in the optimization, we design shaped microwave control pulses that can outperform conventional ($π$-) pulses when applied to sensing of temperature or magnetic field, with a potential sensitivity improvement between 11 and 78\%. Through dynamical modelling of the behaviour of the ensemble, we shed light on the physical behaviour of the ensemble system and propose new routes for further improvement.

quant-ph↗

Laser threshold magnetometry using green light absorption by diamond nitrogen vacancies in an external cavity laser

Nitrogen vacancy (NV) centers in diamond have attracted considerable recent interest for use in quantum sensing, promising increased sensitivity for applications ranging from geophysics to biomedicine. Conventional sensing schemes involve monitoring the change in red fluorescence from the NV center under green laser and microwave illumination. Due to the strong fluorescence background from emission in the NV triplet state and low relative contrast of any change in output, sensitivity is severely restricted by a high optical shot noise level. Here, we propose a means to avoid this issue, by using the change in green pump absorption through the diamond as part of a semiconductor external cavity laser run close to lasing threshold. We show theoretical sensitivity to magnetic field on the pT/sqrt(Hz) level is possible using a diamond with an optimal density of NV centers. We discuss the physical requirements and limitations of the method, particularly the role of amplified spontaneous emission near threshold and explore realistic implementations using current technology.

quant-ph↗

Optimisation of a diamond nitrogen vacancy centre magnetometer for sensing of biological signals

Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrical signal, giving the equivalent readout without direct electrical contact. Such measurements are performed today using bulky and expensive superconducting sensors with poor spatial resolution. An alternative is to use nitrogen vacancy (NV) centres in diamond that promise biocompatibilty and high sensitivity without cryogenic cooling. In this work we present advances in biomagnetometry using NV centres, demonstrating magnetic field sensitivity of approximately 100 pT/$\sqrt{Hz}$ in the DC/low frequency range using a setup designed for biological measurements. Biocompatibility of the setup with a living sample (mouse brain slice) is studied and optimized, and we show work toward sensitivity improvements using a pulsed magnetometry scheme. In addition to the bulk magnetometry study, systematic artifacts in NV-ensemble widefield fluorescence imaging are investigated.

quant-ph↗

Monolithic integration of InP on Si by molten alloy driven selective area epitaxial growth

We report a new approach for monolithic integration of III-V materials into silicon, based on selective area growth and driven by a molten alloy in metal-organic vapor epitaxy. Our method includes elements of both selective area and droplet-mediated growths and combines the advantages of the two techniques. Using this approach, we obtain organized arrays of high crystalline quality InP insertions into (100) oriented Si substrates. Our detailed structural, morphological and optical studies reveal the conditions leading to defect formation. These conditions are then eliminated to optimize the process for obtaining dislocation-free InP nanostructures grown directly on Si and buried below the top surface. The PL signal from these structures exhibits a narrow peak at the InP bandgap energy. The fundamental aspects of the growth are studied by modeling the InP nucleation process. The model is fitted by our x-ray diffraction measurements and correlates well with the results of our transmission electron microscopy and optical investigations. Our method constitutes a new approach for the monolithic integration of active III-V material into Si platform and opens up new opportunities in active Si photonics.

physics.app-ph↗

Detection of biological signals from a live mammalian muscle using a diamond quantum sensor

The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50pT/$\sqrt{Hz}$ sensitivity, we show the first measurements of sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.

physics.bio-ph↗

Cavity-Enhanced Photon Emission from a Single Germanium-Vacancy Center in a Diamond Membrane

The nitrogen-vacancy center in diamond has been explored extensively as a light-matter interface for quantum information applications, however it is limited by low coherent photon emission and spectral instability. Here, we present a promising interface based on an alternate defect with superior optical properties (the germanium-vacancy) coupled to a finesse $\approx11{,}000$ fiber cavity, resulting in a $31^{+11}_{-15}$-fold increase in the spectral density of emission. This work sets the stage for cryogenic experiments, where we predict a measurable increase in the spontaneous emission rate.

quant-ph↗

Nitrogen-vacancy defect emission spectra in the vicinity of an adjustable silver mirror

Optical emitters of quantum radiation in the solid state are important building blocks for emerging technologies making use of the laws of quantum mechanics. The efficiency of photon extraction from the host material is low for many solid-state systems due to their relatively high index of refraction. In this article we experimentally study the emission spectrum of an ensemble of nitrogen-vacancy defects implanted around 8nm below the planar diamond surface and in the vicinity of a planar silver mirror. Scanning the distance between diamond and the mirror, we observe an enhancement of the spectral emission power by up to a factor of 3. We construct a model based on classical dipoles and elucidate the observations as being caused by interference in the far field of the emitters.

quant-ph↗

Observation of the Magneto-Optic Voigt Effect in a Paramagnetic Diamond Membrane

The magneto-optic Voigt effect is observed in a synthetic diamond membrane with a substitutional nitrogen defect concentration in the order of 200 ppm and a nitrogen-vacancy defect sub-ensemble generated through neutron irradiation and annealing. The measured polarisation rotation in the reflected light is observed to be quadratically proportional to the applied magnetic field and to the incident reflection angle. Additionally, it is observed to be modifiable by illuminating the diamond with a 532 nm laser. Spectral analysis of the reflected light under 532 nm illumination shows a slow narrowing of the spectral distribution, indicating a small increase in the overall magnetisation, as opposed to magnetisation degradation caused by heating. Further analysis of the optical power dependence suggest this may be related to a shift in the spin ensembles charge state equilibrium and, by extension, the resulting ensemble magnetisation.

cond-mat.mes-hall↗

Coupling colloidal quantum dots to gap waveguides

The coupling between single photon emitters and integrated photonic circuits is an emerging topic relevant for quantum information science and other nanophotonic applications. We investigate the coupling between a hybrid system of colloidal quantum dots and propagating gap modes of a silicon nitride waveguide system. We furthermore explore the density of optical states of the system by using a scanning probe technique and find that the quantum dots couple significantly to the photonic circuit. Our results indicate that a scalable slot-waveguide might serve as a promising platform in future developments of integrated quantum circuitry.

cond-mat.mes-hall↗

Continuous microwave hole burning and population oscillations in a diamond spin ensemble

Continuous spectral hole burning and spin-level population oscillations are studied in an inhomogeneously broadened diamond-based spin ensemble composed of substitutional nitrogen and nitrogen-vacancy centres created through neutron irradiation and annealing. The burnt spectral features highlight a detuning-dependent homogeneous hole linewidth that is up to three orders of magnitude narrower than the total inhomogeneous ensemble linewidth. Continuous population oscillations are observed to quickly decay beyond a pump and probe detuning of 5 Hz, and are numerically modelled using a five-level system of coupled rate equations. Fourier analysis of these oscillations highlight discrete $^{13}$C hyperfine interactions, with energies within the inhomogeneous ensemble linewidth, as well as suspected nuclear $3/2$-spin coupled signatures likely related to the $^7$Li byproduct of neutron irradiation.

cond-mat.mes-hall↗

Clock transition by continuous dynamical decoupling of a three-level system

We present a novel continuous dynamical decoupling scheme for the construction of a robust qubit in a three-level system. By means of a clock transition adjustment, we first show how robustness to environmental noise is achieved, while eliminating drive-noise, to first-order. We demonstrate this scheme with the spin sub-levels of the NV-centre's electronic ground state. By applying drive fields with moderate Rabi frequencies, the drive noise is eliminated and an improvement of 2 orders of magnitude in the coherence time is obtained compared to the pure dephasing time. We then show how the clock transition adjustment can be tuned to eliminate also the second-order effect of the environmental noise with moderate drive fields. A further improvement of more than 1 order of magnitude in the coherence time is expected and confirmed by simulations. Hence, our scheme prolongs the coherence time towards the lifetime-limit using a relatively simple experimental setup.

quant-ph↗

Precision temperature sensing in the presence of magnetic field noise and vice-versa using nitrogen-vacancy centers in diamond

We demonstrate a technique for precision sensing of temperature or the magnetic field by simultaneously driving two hyperfine transitions involving distinct electronic states of the nitrogen-vacancy center in diamond. Frequency modulation of both driving fields is used with either the same or opposite phase, resulting in the immunity to fluctuations in either the magnetic field or the temperature, respectively. In this way, a sensitivity of 1.4 nT Hz$^{-1/2}$ or 430 $μ$K Hz$^{-1/2}$ is demonstrated. The presented technique only requires a single frequency demodulator and enables the use of phase-sensitive camera imaging sensors. A simple extension of the method utilizing two demodulators allows for simultaneous, independent, and high-bandwidth monitoring of both the magnetic field and temperature.

cond-mat.mes-hall↗

Nitrogen-Vacancy Ensemble Magnetometry Based on Pump Absorption

We demonstrate magnetic field sensing using an ensemble of nitrogen-vacancy centers by recording the variation in the pump-light absorption due to the spin-polarization dependence of the total ground state population. Using a 532 nm pump laser, we measure the absorption of native nitrogen-vacancy centers in a chemical vapor deposited diamond placed in a resonant optical cavity. For a laser pump power of 0.4 W and a cavity finesse of 45, we obtain a noise floor of $\sim$ 100 nT/$\sqrt{\textrm{Hz}}$ spanning a bandwidth up to 125 Hz. We project a photon shot-noise-limited sensitivity of $\sim$ 1 pT/$\sqrt{\textrm{Hz}}$ by optimizing the nitrogen-vacancy concentration and the detection method.

quant-ph↗

Pump-Enhanced Continuous-Wave Magnetometry using Nitrogen-Vacancy Ensembles

Ensembles of nitrogen-vacancy centers in diamond are a highly promising platform for high-sensitivity magnetometry, whose efficacy is often based on efficiently generating and monitoring magnetic-field dependent infrared fluorescence. Here we report on an increased sensing efficiency with the use of a 532-nm resonant confocal cavity and a microwave resonator antenna for measuring the local magnetic noise density using the intrinsic nitrogen-vacancy concentration of a chemical-vapor deposited single-crystal diamond. We measure a near-shot-noise-limited magnetic noise floor of 200 pT/$\sqrt{\text{Hz}}$ spanning a bandwidth up to 159 Hz, and an extracted sensitivity of approximately 3 nT/$\sqrt{\text{Hz}}$, with further enhancement limited by the noise floor of the lock-in amplifier and the laser damage threshold of the optical components. Exploration of the microwave and optical pump-rate parameter space demonstrates a linewidth-narrowing regime reached by virtue of using the optical cavity, allowing an enhanced sensitivity to be achieved, despite an unoptimized collection efficiency of <2 %, and a low nitrogen-vacancy concentration of about 0.2 ppb.

quant-ph↗

Opto-magnetic imaging of neural network activity in brain slices at high resolution using color centers in diamond

We suggest a novel approach for wide-field imaging of the neural network dynamics of brain slices that uses highly sensitivity magnetometry based on nitrogen-vacancy (NV) centers in diamond. In-vitro recordings in brain slices is a proven method for the characterization of electrical neural activity and has strongly contributed to our understanding of the mechanisms that govern neural information processing. However, traditional recordings can only acquire signals from a few positions simultaneously, which severely limits their ability to characterize the dynamics of the underlying neural networks. We suggest to radically extend the scope of this method using the wide-field imaging of the neural magnetic fields across the slice by means of NV magnetometry. Employing comprehensive computational simulations and theoretical analyses, we characterize the spatiotemporal characteristics of the neural magnetic fields and derive the required key performance parameters of an imaging setup based on NV magnetometry. In particular, we determine how the technical parameters determine the achievable spatial resolution for an optimal reconstruction of the neural currents from the measured field distributions. Finally, we compare the imaging of neural slice activity with that of a single planar pyramidal cell. Our results suggest that imaging of neural slice activity will be possible with the upcoming generation of NV magnetic field sensors, while imaging of the activity of a single planar cell remains more challenging.

q-bio.NC↗

Camera-limits for wide-field magnetic resonance imaging of a nitrogen-vacancy spin sensor

Sensitive, real-time optical magnetometry with nitrogen-vacancy centers in diamond relies on accurate imaging of small ($\ll 10^{-2}$) fractional fluorescence changes across the diamond sample. We discuss the limitations on magnetic-field sensitivity resulting from the limited number of photoelectrons that a camera can record in a given time. Several types of camera sensors are analyzed and the smallest measurable magnetic-field change is estimated for each type. We show that most common sensors are of a limited use in such applications, while certain highly specific cameras allow to achieve nanotesla-level sensitivity in $1$~s of a combined exposure. Finally, we demonstrate the results obtained with a lock-in camera that pave the way for real-time, wide-field magnetometry at the nanotesla level and with micrometer resolution.

physics.ins-det↗

Optimised frequency modulation for continuous-wave optical magnetic resonance sensing using nitrogen-vacancy ensembles

Magnetometers based on ensembles of nitrogen-vacancy centres are a promising platform for continuously sensing static and low-frequency magnetic fields. Their combination with phase-sensitive (lock-in) detection creates a highly versatile sensor with a sensitivity that is proportional to the derivative of the optical magnetic resonance lock-in spectrum, which is in turn dependant on the lock-in modulation parameters. Here we study the dependence of the lock-in spectral slope on the modulation of the spin-driving microwave field. Given the presence of the intrinsic nitrogen hyperfine spin transitions, we experimentally show that when the ratio between the hyperfine linewidth and their separation is $\gtrsim 1/4$, square-wave based frequency modulation generates the steepest slope at modulation depths exceeding the separation of the hyperfine lines, compared to sine-wave based modulation. We formulate a model for calculating lock-in spectra which shows excellent agreement with our experiments, and which shows that an optimum slope is achieved when the linewidth/separation ratio is $\lesssim 1/4$ and the modulation depth is less then the resonance linewidth, irrespective of the modulation function used.

physics.ins-det↗