SearcharxivSearch

arXiv subjects

Alexander Knetsch

Publications and source records attributed to Alexander Knetsch.

16 recordsLinked to original sources

Multi-GeV Electron Combs from a Plasma Wakefield Accelerator

Plasma accelerators now produce GeV-class electron beams with brightness and stability sufficient to drive free-electron lasers. Beyond this, they possess a unique yet largely unexplored capability: shaping the phase space of the beam in situ during injection, on femtosecond or shorter timescales. Here we demonstrate this capability by generating a multi-GeV electron comb comprising more than ten microbunches simultaneously separated in both energy and time. Periodic pinching of the drive beam inside its self-excited plasma wake sequentially injects microbunches via ionization of embedded helium atoms at successive betatron oscillations, while the gently varying plasma density maps each bunchlet to a distinct wake phase, compressing electrons trapped over a ~17 cm region into a comb only micrometers long. Individual microbunches exhibit percent-level energy spreads, energy spacing up to ten percent, and contain several picocoulomb charge. The percent-level spreads and parabolic energy-spacing trend provide experimental evidence for sub-femtosecond microbunch durations and few-femtosecond separations as revealed by beam-loading analysis and confirmed by particle-in-cell simulations. This work demonstrates femtosecond, in-situ phase-space shaping in plasma accelerators, paving the way for electron beams with tailored energy-time structure.

physics.acc-ph

Initial Performance of the E320 Tracker

Our recent study discussed the prospects for measuring single positrons produced in electron-laser collisions via the nonlinear Breit-Wheeler deep-tunneling process in the SLAC Experiment 320 at the FACET-II RF LINAC. In this work, we demonstrate how a tracking detector, that is a scaled-down version of the one discussed in the prospective simulation study, enables the measurement. This prototype detector, installed in Aug 2024, is built out of five layers of single ALPIDE chips. The data are taken from several standalone runs completed in Nov 2024 and Feb 2025. We use positrons generated through conversion of Bremsstrahlung photons as a proxy to the nonlinear Breit-Wheeler process. These positrons are produced by the beam electrons in a thin Beryllium foil close to the experiment's interaction point. The tracking approach used in this initial work is based on a Hough-Transform seeding algorithm followed by a straight line fit confined to the detector volume. Even with this relatively simple approach, we are able to measure a signal rate of $(1.20\pm0.06_{stat.}\pm0.56_{syst.})\times10^{-1}$ positrons per shot. This signal rate is comparable to the nonlinear Breit-Wheeler rate expected in the main experiment. Notably, the measurement is achieved under an extreme, unprecedented background hit density of ~1.7/mm$^2$, unlike the main experiment, where at least a twice lower density is expected. This large background is mostly due to secondary particles produced when the large flux of Bremsstrahlung photons interacts with the material of the beamline elements. When the foil is retracted, the false-positive signal rate is shown to be four orders of magnitude smaller than the signal rate. We further show that the high spatial tracking resolution of ~5 micron allows to characterize the positrons' spectra. The results are compared to simulations, which are found to be compatible with the data.

hep-ex

Strong-field focusing of high-energy particles in beam-multifoil collisions

Extreme beams of charged particles and photons, reaching ultrahigh densities or producing intense gamma-ray bursts, are central to accelerator physics, laboratory astrophysics, and strong-field quantum electrodynamics research. Yet their generation is hindered by conventional focusing methods at multi-GeV energies that rely on massive magnetic assemblies, limiting compactness and attainable density. Here we report the first experimental observation of a fundamentally new focusing mechanism, in which a high-energy charged-particle beam is focused by its own magnetic field reflected from a stack of thin metallic foils via near-field coherent-transition-radiation. The experiment, performed at SLAC's FACET-II facility, reveals strong, cumulative focusing across a broad range of beam configurations, enabled by the delivered 10 GeV, 1 nC, 10 Hz electron beam. The measurements closely agree with predictions from an analytical model and particle-in-cell simulations. These results demonstrate that multifoil focusing is a remarkably straightforward, self-aligned approach to the generation of ultrahigh density beams, opening a path to explore unprecedented regimes of beam-matter interaction and high-energy radiation.

physics.acc-ph

Effect of Synchrotron Radiation on Staged Plasma Wakefield Accelerators

In a staged, beam-driven, plasma wakefield accelerator, electrons are accelerated in a sequence of plasma stages, each powered by a driver electron bunch. Between each stage, a magnetic chicane is used to dispose of the spent driver and to inject the new fresh one, while transporting the witness bunch. We discuss the effect of synchrotron radiation in the interstage section on the accelerating gradient and on the final energy reach of such a machine.

physics.acc-ph

Precision alignment and tolerance of a plasma wakefield accelerator in a laser-ionized plasma source

We present a novel method for aligning a laser ionized plasma source to a pair of ultra-relativistic electron beams that comprise a plasma wakefield accelerator (PWFA). We achieve alignment by analyzing the plasma afterglow light observed at two longitudinal locations as the plasma column is scanned across the electron beam. By analyzing the relative plasma light intensity at the two locations, we aligned an 85-cm plasma source to a 10 GeV, 1.6 nC electron beam to within 10 um offset, 10 urad tilt. The alignment is verified by analyzing the drive beam energy loss, energy transfer efficiency, and the witness beam energy gain as a function of the misalignment between the beams and the plasma. From this measurement, we extract the alignment tolerance required between the laser-ionized plasma source and electron beams, an important metric necessary for collider design studies or light source applications based on a laser-ionized plasma source.

physics.acc-ph

A High-Flux Electron Detector System to Measure Non-linear Compton Scattering at LUXE

Recently, advancements in high-intensity laser technology have enabled the exploration of non-perturbative Quantum Electrodynamics (QED) in strong-field regimes. Notable aspects include non-linear Compton scattering and Breit-Wheeler pair production, observable when colliding high-intensity laser pulses and relativistic electron beams. The LUXE experiment at DESY and the E-320 experiment at SLAC aim to study these phenomena by measuring the created high-flux Compton electrons and photons. We propose a novel detector system featuring a segmented gas-filled Cherenkov detector with a scintillator screen and camera setup, designed to efficiently detect high-flux Compton electrons. Preliminary results from E-320 measurement campaigns demonstrate methods for reconstructing electron energy spectra, aiming to reveal crucial features of non-perturbative QED.

physics.ins-det

Design Initiative for a 10 TeV pCM Wakefield Collider

This document outlines a community-driven Design Study for a 10 TeV pCM Wakefield Accelerator Collider. The 2020 ESPP Report emphasized the need for Advanced Accelerator R\&D, and the 2023 P5 Report calls for the ``delivery of an end-to-end design concept, including cost scales, with self-consistent parameters throughout." This Design Study leverages recent experimental and theoretical progress resulting from a global R\&D program in order to deliver a unified, 10 TeV Wakefield Collider concept. Wakefield Accelerators provide ultra-high accelerating gradients which enables an upgrade path that will extend the reach of Linear Colliders beyond the electroweak scale. Here, we describe the organization of the Design Study including timeline and deliverables, and we detail the requirements and challenges on the path to a 10 TeV Wakefield Collider.

physics.acc-ph

Experimental generation of extreme electron beams for advanced accelerator applications

In this Letter we report on the experimental generation of high energy (10 GeV), ultra-short (fs-duration), ultra-high current (0.1 MA), petawatt peak power electron beams in a particle accelerator. These extreme beams enable the exploration of a new frontier of high intensity beam-light and beam-matter interactions broadly relevant across fields ranging from laboratory astrophysics to strong field quantum electrodynamics and ultra-fast quantum chemistry. We demonstrate our ability to generate and control the properties of these electron beams by means of a laser-electron beam shaping technique. This experimental demonstration opens the door to on-the-fly customization of extreme beam current profiles for desired experiments and is poised to benefit a broad swathe of cross-cutting applications of relativistic electron beams.

physics.acc-ph

Correlations between X-rays, Visible Light and Drive-Beam Energy Loss Observed in Plasma Wakefield Acceleration Experiments at FACET-II

This study documents several correlations observed during the first run of the plasma wakefield acceleration experiment E300 conducted at FACET-II, using a single drive electron bunch. The established correlations include those between the measured maximum energy loss of the drive electron beam and the integrated betatron x-ray signal, the calculated total beam energy deposited in the plasma and the integrated x-ray signal, among three visible light emission measuring cameras, and between the visible plasma light and x-ray signal. The integrated x-ray signal correlates almost linearly with both the maximum energy loss of the drive beam and the energy deposited into the plasma, demonstrating its usability as a measure of energy transfer from the drive beam to the plasma. Visible plasma light is found to be a useful indicator of the presence of wake at three locations that overall are two meters apart. Despite the complex dynamics and vastly different timescales, the x-ray radiation from the drive bunch and visible light emission from the plasma may prove to be effective non-invasive diagnostics for monitoring the energy transfer from the beam to the plasma in future high-repetition-rate experiments.

physics.plasm-ph

High average gradient in a laser-gated multistage plasma wakefield accelerator

Plasma wakefield accelerators driven by particle beams are capable of providing accelerating gradient several orders of magnitude higher than currently used radio-frequency technology, which could reduce the length of particle accelerators, with drastic influence on the development of future colliders at TeV energies and the minimization of x-ray free-electron lasers. Since inter-plasma components and distances are among the biggest contributors to the total accelerator length, the design of staged plasma accelerators is one of the most important outstanding questions in order to render this technology instrumental. Here, we present a novel concept to optimize inter-plasma distances in a staged beam-driven plasma accelerator by drive-beam coupling in the temporal domain and gating the accelerator via a femtosecond ionization laser.

physics.acc-ph

Channeling Acceleration in Crystals and Nanostructures and Studies of Solid Plasmas: New Opportunities

Plasma wakefield acceleration (PWFA) has shown illustrious progress and resulted in an impressive demonstration of tens of GeV particle acceleration in meter-long single structures. To reach even higher energies in the 1 TeV to 10 TeV range, a promising scheme is channeling acceleration in solid-density plasmas within crystals or nanostructures. The E336 experiment studies the beam-nanotarget interaction with the highly compressed electron bunches available at the FACET-II accelerator. These studies furthermore involve an in-depth research on dynamics of beam-plasma instabilities in ultra-dense plasma, its development and suppression in structured media like carbon nanotubes and crystals, and its potential use to transversely modulate the electron bunch.

physics.acc-ph

Extremely Dense Gamma-Ray Pulses in Electron Beam-Multifoil Collisions

Sources of high-energy photons have important applications in almost all areas of research. However, the photon flux and intensity of existing sources is strongly limited for photon energies above a few hundred keV. Here we show that a high-current ultrarelativistic electron beam interacting with multiple submicrometer-thick conducting foils can undergo strong self-focusing accompanied by efficient emission of gamma-ray synchrotron photons. Physically, self-focusing and high-energy photon emission originate from the beam interaction with the near-field transition radiation accompanying the beam-foil collision. This near field radiation is of amplitude comparable with the beam self-field, and can be strong enough that a single emitted photon can carry away a significant fraction of the emitting electron energy. After beam collision with multiple foils, femtosecond collimated electron and photon beams with number density exceeding that of a solid are obtained. The relative simplicity, unique properties, and high efficiency of this gamma-ray source open up new opportunities for both applied and fundamental research including laserless investigations of strong-field QED processes with a single electron beam.

physics.plasm-ph

Controlled density-downramp injection in a beam-driven plasma wakefield accelerator

This paper describes the utilization of beam-driven plasma wakefield acceleration to implement a high-quality plasma cathode via density-downramp injection in a short injector stage at the FLASHForward facility at DESY. Electron beams with charge of up to 105 pC and energy spread of a few percent were accelerated by a tunable effective accelerating field of up to 2.7 GV/m. The plasma cathode was operated drift-free with very high injection efficiency. Sources of jitter, the emittance and divergence of the resulting beam were investigated and modeled, as were strategies for performance improvements that would further increase the wide-ranging applications for a plasma cathode with the demonstrated operational stability

physics.acc-ph

Plasma-photonic spatiotemporal synchronization of relativistic electron and laser beams

Modern particle accelerators and their applications increasingly rely on precisely coordinated interactions of intense charged particle and laser beams. Femtosecond-scale synchronization alongside micrometre-scale spatial precision are essential e.g. for pump-probe experiments, seeding and diagnostics of advanced light sources and for plasma-based accelerators. State-of-the-art temporal or spatial diagnostics typically operate with low-intensity beams to avoid material damage at high intensity. As such, we present a plasma-based approach, which allows measurement of both temporal and spatial overlap of high-intensity beams directly at their interaction point. It exploits amplification of plasma afterglow arising from the passage of an electron beam through a laser-generated plasma filament. The corresponding photon yield carries the spatiotemporal signature of the femtosecond-scale dynamics, yet can be observed as a visible light signal on microsecond-millimetre scales.

physics.plasm-ph

Electron bunch generation from a plasma photocathode

Plasma waves generated in the wake of intense, relativistic laser or particle beams can accelerate electron bunches to giga-electronvolt (GeV) energies in centimetre-scale distances. This allows the realization of compact accelerators having emerging applications, ranging from modern light sources such as the free-electron laser (FEL) to energy frontier lepton colliders. In a plasma wakefield accelerator, such multi-gigavolt-per-metre (GV m$^{-1}$) wakefields can accelerate witness electron bunches that are either externally injected or captured from the background plasma. Here we demonstrate optically triggered injection and acceleration of electron bunches, generated in a multi-component hydrogen and helium plasma employing a spatially aligned and synchronized laser pulse. This ''plasma photocathode'' decouples injection from wake excitation by liberating tunnel-ionized helium electrons directly inside the plasma cavity, where these cold electrons are then rapidly boosted to relativistic velocities. The injection regime can be accessed via optical density down-ramp injection, is highly tunable and paves the way to generation of electron beams with unprecedented low transverse emittance, high current and 6D-brightness. This experimental path opens numerous prospects for transformative plasma wakefield accelerator applications based on ultra-high brightness beams.

physics.acc-ph

Downramp-assisted underdense photocathode electron bunch generation in plasma wakefield accelerators

It is shown that the requirements for high quality electron bunch generation and trapping from an underdense photocathode in plasma wakefield accelerators can be substantially relaxed through localizing it on a plasma density downramp. This depresses the phase velocity of the accelerating electric field until the generated electrons are in phase, allowing for trapping in shallow trapping potentials. As a consequence the underdense photocathode technique is applicable by a much larger number of accelerator facilities. Furthermore, dark current generation is effectively suppressed.

physics.acc-ph